Multi i/o bar din Riello UPS - Part number: RIEYSKCIO2B
Ausverkauft - Auftragsrückstand
Beim Hersteller zu bestellen
262,63 USD

Importsteuern ausgeschlossen

bitte einloggen

Multi i/o bar din Riello UPS - Part number: RIEYSKCIO2B

Riello UPS

Multi I/O interface in DIN rail version for UPS integration with control systems, configurable relay inputs/outputs and Modbus/Jbus communication over RS485. It enables multiple serial links, multi-polling and monitoring via RS232 according to the installed configuration. Riello compatibility: Multi I/O and Riello UPS systems prepared for I/O interfaces. Multi I/O interface in DIN rail version for UPS integration with control systems, configurable relay inputs/outputs and Modbus/Jbus communication over RS485. It enables multiple serial links, multi-polling and monitoring via RS232 according to the installed configuration. Riello compatibility: Multi I/O and Riello UPS systems prepared for I/O interfaces.

MPNs YSKCIO2B, RIEYSKCIO2B
EAN 8023251009778
HS-Code 85072000
Weight 1.5 kg
Volumengewicht 2.68 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

262,63 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein autorisierter Händler von Riello UPS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Produktinformationen

Beschreibung

<div class="row"> <div class="col-xs-12"> <h3>Multi I/O interface DIN rail version</h3> <p>Communication interface designed to integrate the UPS with control and monitoring systems through configurable input and output signals. Its main function is to transform UPS events, statuses and alarms into contacts or data that can be used by supervisors, PLCs and BMS systems. The card supports multiple serial connections and allows UPS polling by more than one device, a useful feature in installations with firewalls, separate networks or multiple supervision systems. Communication with the UPS is via RS232, while dialogue on RS485 lines can use the Modbus/Jbus protocol.</p> <h4>Technical features</h4> <ul> <li>Configurable relay inputs and outputs for control and monitoring.</li> <li>Communication with UPS via RS232.</li> <li>Modbus/Jbus protocol on RS485 line.</li> <li>Possibility to connect two devices to a single UPS communication port.</li> <li>Indicated format: DIN rail version; mechanical details not reported.</li> </ul> <h4>Integration process</h4> <p>Integration requires contact wiring, serial communication setup and event testing. It is recommended to document configured inputs, outputs and logic for maintenance and future troubleshooting.</p> <h4>Configuration software</h4> <p>Configuration depends on the interface settings and on the supervision software connected to the serial or Modbus/Jbus line. Event mapping should follow the technical manual. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Multi I/O and Riello UPS systems prepared for I/O interfaces.</p> </div> </div> <div class="row"> <div class="col-xs-12"> <h3>Multi I/O interface DIN rail version</h3> <p>Communication interface designed to integrate the UPS with control and monitoring systems through configurable input and output signals. Its main function is to transform UPS events, statuses and alarms into contacts or data that can be used by supervisors, PLCs and BMS systems. The card supports multiple serial connections and allows UPS polling by more than one device, a useful feature in installations with firewalls, separate networks or multiple supervision systems. Communication with the UPS is via RS232, while dialogue on RS485 lines can use the Modbus/Jbus protocol.</p> <h4>Technical features</h4> <ul> <li>Configurable relay inputs and outputs for control and monitoring.</li> <li>Communication with UPS via RS232.</li> <li>Modbus/Jbus protocol on RS485 line.</li> <li>Possibility to connect two devices to a single UPS communication port.</li> <li>Indicated format: DIN rail version; mechanical details not reported.</li> </ul> <h4>Integration process</h4> <p>Integration requires contact wiring, serial communication setup and event testing. It is recommended to document configured inputs, outputs and logic for maintenance and future troubleshooting.</p> <h4>Configuration software</h4> <p>Configuration depends on the interface settings and on the supervision software connected to the serial or Modbus/Jbus line. Event mapping should follow the technical manual. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Multi I/O and Riello UPS systems prepared for I/O interfaces.</p> </div> </div>

technischen Spezifikationen

Art des Zubehörs/Ersatzteils
sonstige

Unser Unternehmen Bewertungen