ICA-10DI6DO-G60A-IO PEPPERL+FUCHS - Part number: 314644
Ausverkauft - Auftragsrückstand
Beim Hersteller zu bestellen
372,72 USD

Importsteuern ausgeschlossen

bitte einloggen

ICA-10DI6DO-G60A-IO PEPPERL+FUCHS - Part number: 314644

PEPPERL+FUCHS

I/O hub ICA-10DI6DO-G60A-IO ICA-10DI6DO-G60A-IO Sturdy metallic housing IO-link interface for service and process data 10 digital inputs and 6 digital outputs Logic level can be configured per port Filter time can be configured per port Pulse extension can be configured per port I/O hub ICA-10DI6DO-G60A-IO ICA-10DI6DO-G60A-IO Sturdy metallic housing IO-link interface for service and process data 10 digital inputs and 6 digital outputs Logic level can be configured per port Filter time can be configured per port Pulse extension can be configured per port

MPNs 314644, PEP314644, ICA-10DI6DO-G60A-IO
HS-Code 85371000
Weight 0.4 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

372,72 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  ICA-10DI6DO-G60A-IO Product Description I/O hub with IO-Link interface for 10 digital inputs and 6 digital outputs General specifications UL File NumberE223772 Functional safety related parameters MTTFd2111 a Indicators/operating means LED UAUX Green: Actuator supply voltage OKRed: Actuator supply voltage < 18 V LED IO-LinkGreen: module is switched on, no communicationFlashing green: communication OKRed: signal line overload LED AOrange: status indicator channel A Red: peripheral error LED BWhite: status indicator channel B Red: peripheral error LED USGreen: system/sensor supply voltage OKRed: system/sensor supply voltage < 18 VFlashing red: sensor supply voltage overload Electrical specifications Rated operating voltage18 ... 30 V Nominal voltage24 V DC Nominal current4 A Current consumptiontyp. 80 mA Interface Interface typeIO-Link Device profileIdentification and Diagnosis - I&D Transfer rateCOM3 (230.4 kbits/s) IO-Link Revision1.1 Min. cycle time2 ms Process data widthInput 4 ByteOutput 4 Byte SIO mode supportno Device ID0x0F0202 (983554) Compatible master port typeB Input Number/Type10 digital inputs (X1 - X5) , 2-, 3-, 4-wire PNP, DC , Type 3 according to IEC 61131-2 Sensor supplyDepending on the IO-Link master, max. 500 mA per module Output Number/Type6 digital outputs (X6 - X8) , 2-, 3-wire connection Output rated operating currentDepending on the IO-Link master, max. 500 mA per channel Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardType 1 according to IEC 61131-2 Emitted interferenceEN 61000-6-2:2005 Noise immunityEN 61000-6-4:2007+A1:2011 Ambient conditions Ambient temperature-20 ... 70 °C (-4 ... 158 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Relative humiditymax. 95 % Altitude0 ... 2000 m Shock and impact resistance50 g, 11 ms, all axes Vibration resistance15 g / 5 ... 500 Hz Pollution degree3 Mechanical specifications Degree of protectionIP65/IP67/IP69K ConnectionPower supply/IO-Link M12, A-coded Inputs/Outputs M12, A-coded Material ContactsCuSn, gold-plated CuNi, gold-plated HousingDiecast zinc Plastic partsPA SealFKM Mass400 g Construction typeField housing Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001597 ETIM 7.0EC001597 ETIM 6.0EC001597 ETIM 5.0EC001597 UNSPSC 12.132151705 Datasheet excerpt: Technical data of  ICA-10DI6DO-G60A-IO Product Description I/O hub with IO-Link interface for 10 digital inputs and 6 digital outputs General specifications UL File NumberE223772 Functional safety related parameters MTTFd2111 a Indicators/operating means LED UAUX Green: Actuator supply voltage OKRed: Actuator supply voltage < 18 V LED IO-LinkGreen: module is switched on, no communicationFlashing green: communication OKRed: signal line overload LED AOrange: status indicator channel A Red: peripheral error LED BWhite: status indicator channel B Red: peripheral error LED USGreen: system/sensor supply voltage OKRed: system/sensor supply voltage < 18 VFlashing red: sensor supply voltage overload Electrical specifications Rated operating voltage18 ... 30 V Nominal voltage24 V DC Nominal current4 A Current consumptiontyp. 80 mA Interface Interface typeIO-Link Device profileIdentification and Diagnosis - I&D Transfer rateCOM3 (230.4 kbits/s) IO-Link Revision1.1 Min. cycle time2 ms Process data widthInput 4 ByteOutput 4 Byte SIO mode supportno Device ID0x0F0202 (983554) Compatible master port typeB Input Number/Type10 digital inputs (X1 - X5) , 2-, 3-, 4-wire PNP, DC , Type 3 according to IEC 61131-2 Sensor supplyDepending on the IO-Link master, max. 500 mA per module Output Number/Type6 digital outputs (X6 - X8) , 2-, 3-wire connection Output rated operating currentDepending on the IO-Link master, max. 500 mA per channel Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardType 1 according to IEC 61131-2 Emitted interferenceEN 61000-6-2:2005 Noise immunityEN 61000-6-4:2007+A1:2011 Ambient conditions Ambient temperature-20 ... 70 °C (-4 ... 158 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Relative humiditymax. 95 % Altitude0 ... 2000 m Shock and impact resistance50 g, 11 ms, all axes Vibration resistance15 g / 5 ... 500 Hz Pollution degree3 Mechanical specifications Degree of protectionIP65/IP67/IP69K ConnectionPower supply/IO-Link M12, A-coded Inputs/Outputs M12, A-coded Material ContactsCuSn, gold-plated CuNi, gold-plated HousingDiecast zinc Plastic partsPA SealFKM Mass400 g Construction typeField housing Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001597 ETIM 7.0EC001597 ETIM 6.0EC001597 ETIM 5.0EC001597 UNSPSC 12.132151705

Unser Unternehmen Bewertungen