AS-Interface analog module VBA-2E-G4-U VBA-2E-G4-U Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat cable Function display for bus and inputs Supply of inputs external or from the module, as required AS-Interface analog module VBA-2E-G4-U VBA-2E-G4-U Degree of protection IP65 Flat or round cable connection (via standardized EEMS base, not included with delivery) Cable piercing method for flat cable Function display for bus and inputs Supply of inputs external or from the module, as required

MPNs 104423, PEP104423, VBA-2E-G4-U
HS-Code 85371091
Weight 0.35 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

auf Anfrage erhältlich

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  VBA-2E-G4-U Product Description G4 module IP652 analog inputs (voltage) General specifications Node typeStandard node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd160 a at 30 °C Indicators/operating means LED FAULTerror display; LED redred: communication errorred flashing: peripheral error LED PWRAS-Interface voltage; LED green LED ANALOGstatus input signal; LED greenoff: not connected (peripheral error)green: 0 V ≤ U ≤ 11.5 Vgreen flashing: U > 11.5 V (peripheral error) LED AUXext. auxiliary voltage UAUX ; LED green Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA Protection classIII Input Number/Type2 analog inputs (voltage), 0 ... 10 V Supplyfrom AS-Interface or from external auxiliary voltage as required UAUX Current loading capacity≤ 200 mA from AS-Interface ≤ 500 mA from external auxiliary voltage UAUX Input resistance100 kΩ Resolution16 Bit / 1 mV Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P0mains power frequency filterP0=1, 50 Hz filter activeP0=0, 60 Hz filter active P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Message of peripheral errorP2=1, peripheral error is reportedP2=0, peripheral error is not reported P3not used Ambient conditions Ambient temperature0 ... 70 °C (32 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP65 Connectioncable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs: 2 x M16 x 1.5 cable glands and cage tension spring terminals, 1 x M12 x 1.5 cable gland (not used) Material HousingPA 6 GF30 Mass350 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2E-G4-U Product Description G4 module IP652 analog inputs (voltage) General specifications Node typeStandard node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd160 a at 30 °C Indicators/operating means LED FAULTerror display; LED redred: communication errorred flashing: peripheral error LED PWRAS-Interface voltage; LED green LED ANALOGstatus input signal; LED greenoff: not connected (peripheral error)green: 0 V ≤ U ≤ 11.5 Vgreen flashing: U > 11.5 V (peripheral error) LED AUXext. auxiliary voltage UAUX ; LED green Electrical specifications Auxiliary voltage (output)24 V DC ± 15 % PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA Protection classIII Input Number/Type2 analog inputs (voltage), 0 ... 10 V Supplyfrom AS-Interface or from external auxiliary voltage as required UAUX Current loading capacity≤ 200 mA from AS-Interface ≤ 500 mA from external auxiliary voltage UAUX Input resistance100 kΩ Resolution16 Bit / 1 mV Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P0mains power frequency filterP0=1, 50 Hz filter activeP0=0, 60 Hz filter active P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Message of peripheral errorP2=1, peripheral error is reportedP2=0, peripheral error is not reported P3not used Ambient conditions Ambient temperature0 ... 70 °C (32 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP65 Connectioncable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs: 2 x M16 x 1.5 cable glands and cage tension spring terminals, 1 x M12 x 1.5 cable gland (not used) Material HousingPA 6 GF30 Mass350 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535

Unser Unternehmen Bewertungen