VBA-2E-KE5-IJL/UJL PEPPERL+FUCHS - Part number: 288595
Ausverkauft - Auftragsrückstand
Beim Hersteller zu bestellen
424,40 USD

Importsteuern ausgeschlossen

bitte einloggen

VBA-2E-KE5-IJL/UJL PEPPERL+FUCHS - Part number: 288595

PEPPERL+FUCHS

AS-Interface analog module VBA-2E-KE5-IJL/UJL VBA-2E-KE5-IJL/UJL Housing with push-in connection technology and mechanically coded terminal blocks Housing width 19 mm, installation in the switch cabinet on DIN mounting rail Sensors can be supplied either from the AS-Interface or external auxiliary voltage, as preferred Function indicator for the bus, external auxiliary voltage, internal sensor supply, and inputs AS-Interface analog module VBA-2E-KE5-IJL/UJL VBA-2E-KE5-IJL/UJL Housing with push-in connection technology and mechanically coded terminal blocks Housing width 19 mm, installation in the switch cabinet on DIN mounting rail Sensors can be supplied either from the AS-Interface or external auxiliary voltage, as preferred Function indicator for the bus, external auxiliary voltage, internal sensor supply, and inputs

MPNs 288595, PEP288595, VBA-2E-KE5-IJL/UJL
HS-Code 85371091
Weight 0.11 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

424,40 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  VBA-2E-KE5-IJL/UJL Product Description Switch cabinet module2 analog Inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 MTBF154 a Indicators/operating means LED FAULTFault indication: red LEDRed: communication error or address is 0Red flashing: peripheral fault LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDGreen: voltage OKFlashing green: address 0 or peripheral error LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 70 mA (without sensors) / max. 200 mA Protection classIII Current consumptionIAUX ≤ 650 mA Surge protectionUAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Input Number/Type2 analog inputsCurrent: 0 ... 20 mA/4 ... 20 mAvoltage: 0 ... 10 V SupplyFrom AS-Interface (switch setting INT, default setting) or from auxiliary voltage UAUX (switch setting AUX) Current loading capacity≤ 100 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA From auxiliary voltage UAUX (AUX switch position) , overload and short-circuit protected Input resistancecurrent input: max. 70 Ω voltage input: 100 kΩ Accuracy0.1 % of input signal range at 25 °C (298 K) Resolution15 Bit Temperature influence0.0025 %/K of input signal range Output Temperature influence1 µA/K or 0,3 mV/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID1 codeF ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Indication of the peripheral fault by exceeding measuring rangeP2=1, peripheral fault is reportedP2=0, peripheral fault is not reported P3P3=1, normal operating modeP3=0, both channels in current mode and without recognition of wire breakage Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 ConnectionRemovable push-in terminalsrated connection capacity:rigid: 0.20 mm2 ... 1.5 mm2flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass110 g MountingDIN mounting rail NoteMax. length of jumpers = 5 cm Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2E-KE5-IJL/UJL Product Description Switch cabinet module2 analog Inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 MTBF154 a Indicators/operating means LED FAULTFault indication: red LEDRed: communication error or address is 0Red flashing: peripheral fault LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDGreen: voltage OKFlashing green: address 0 or peripheral error LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 70 mA (without sensors) / max. 200 mA Protection classIII Current consumptionIAUX ≤ 650 mA Surge protectionUAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Input Number/Type2 analog inputsCurrent: 0 ... 20 mA/4 ... 20 mAvoltage: 0 ... 10 V SupplyFrom AS-Interface (switch setting INT, default setting) or from auxiliary voltage UAUX (switch setting AUX) Current loading capacity≤ 100 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA From auxiliary voltage UAUX (AUX switch position) , overload and short-circuit protected Input resistancecurrent input: max. 70 Ω voltage input: 100 kΩ Accuracy0.1 % of input signal range at 25 °C (298 K) Resolution15 Bit Temperature influence0.0025 %/K of input signal range Output Temperature influence1 µA/K or 0,3 mV/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID1 codeF ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Indication of the peripheral fault by exceeding measuring rangeP2=1, peripheral fault is reportedP2=0, peripheral fault is not reported P3P3=1, normal operating modeP3=0, both channels in current mode and without recognition of wire breakage Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 ConnectionRemovable push-in terminalsrated connection capacity:rigid: 0.20 mm2 ... 1.5 mm2flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass110 g MountingDIN mounting rail NoteMax. length of jumpers = 5 cm Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535

Unser Unternehmen Bewertungen