VBG-DN-K20-DMD PEPPERL+FUCHS - Part number: 190325
auf Anfrage erhältlich

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

VBG-DN-K20-DMD PEPPERL+FUCHS - Part number: 190325

PEPPERL+FUCHS

AS-Interface gateway VBG-DN-K20-DMD VBG-DN-K20-DMD Gateway compliant with AS-Interface specification 3.0 2 AS-Interface networks Dublicate addressing detection Earth fault detection AS-Interface noise detection Easy commissioning by graphic display Commissioning, locally on the gateway or via AS-i Control Tools software Fault diagnosis via LEDs and grafic display AS-Interface monitor or extended AS-Interface diagnostic read via display Ethernet diagnostic interface AS-Interface gateway VBG-DN-K20-DMD VBG-DN-K20-DMD Gateway compliant with AS-Interface specification 3.0 2 AS-Interface networks Dublicate addressing detection Earth fault detection AS-Interface noise detection Easy commissioning by graphic display Commissioning, locally on the gateway or via AS-i Control Tools software Fault diagnosis via LEDs and grafic display AS-Interface monitor or extended AS-Interface diagnostic read via display Ethernet diagnostic interface

MPNs 190325, PEP190325, VBG-DN-K20-DMD
HS-Code 85176900
Weight 0.52 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

auf Anfrage erhältlich

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  VBG-DN-K20-DMD Product Description DeviceNet Gateway, double master for 2 AS-Interface networks General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED MNSModule/net status; LED green/red Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 200 mA from AS-Interface circuit 1≤ 70 mA from AS-Interface circuit 2 Interface 1 ProtocolDeviceNet Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Connection AS-Interfacespring terminals, removable DeviceNet5-pin CombiCon connector according to DeviceNet specification Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2001, EN 50295:1999 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass520 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBG-DN-K20-DMD Product Description DeviceNet Gateway, double master for 2 AS-Interface networks General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED MNSModule/net status; LED green/red Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 200 mA from AS-Interface circuit 1≤ 70 mA from AS-Interface circuit 2 Interface 1 ProtocolDeviceNet Interface 2 Interface typeRS 232, serial Diagnostic Interface Transfer rate19,2 kBit/s Connection AS-Interfacespring terminals, removable DeviceNet5-pin CombiCon connector according to DeviceNet specification Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2001, EN 50295:1999 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Mass520 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535