VBG-ENX-K30-DMD-S16-EV PEPPERL+FUCHS - Part number: 254539
Ausverkauft - Auftragsrückstand
Beim Hersteller zu bestellen
4.914,87 USD

Importsteuern ausgeschlossen

bitte einloggen

VBG-ENX-K30-DMD-S16-EV PEPPERL+FUCHS - Part number: 254539

PEPPERL+FUCHS

AS-Interface Gateway/Safety Monitor VBG-ENX-K30-DMD-S16-EV VBG-ENX-K30-DMD-S16-EV Gateway and safety monitor in one housing Connection to Ethernet Modbus TCP/IP SafeLink Integrated data decoupling Integrated webserver Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849 Memory card for configuration data 2 AS-Interface networks 2 safe output relays and 2 safe electronic outputs Integrated switch allows line topology DLR technology supports ring topology Max. 32 independent safety loops AS-Interface Gateway/Safety Monitor VBG-ENX-K30-DMD-S16-EV VBG-ENX-K30-DMD-S16-EV Gateway and safety monitor in one housing Connection to Ethernet Modbus TCP/IP SafeLink Integrated data decoupling Integrated webserver Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849 Memory card for configuration data 2 AS-Interface networks 2 safe output relays and 2 safe electronic outputs Integrated switch allows line topology DLR technology supports ring topology Max. 32 independent safety loops

MPNs 254539, PEP254539, VBG-ENX-K30-DMD-S16-EV
HS-Code 85176900
Weight 0.8 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

4.914,87 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  VBG-ENX-K30-DMD-S16-EV Product Description EtherNet/IP + Modbus TCP Gateway with integrated safety monitor, double master for 2 AS-Interface networks, power supply input with data decoupling General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display Data decouplingintegrated Switch-on delay< 10 s Response delay< 40 ms UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e MTTFd200 a B10d2 E+7 Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED ETHERNETethernet active; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED EDM/StartExternal device monitoring circuit inputs closed, 4x yellow LEDs LED output circuitOutput circuit closed; 4 x green LEDs Button4 Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltage26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC Rated operating current≤ 300 mA from AS-Interface Power supplymax. 4 A per AS-Interface circuit Interface 1 Interface type2 x RJ-45 ProtocolEtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3 supports device level ring protocol DLR Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection Interface 2 Interface typeEthernet: RJ-45 Diagnostic Interface Transfer rate10 MBit/s Interface 3 Interface typeChip card slot Input Number/Type4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) Output Safety outputOutput circuits 1 and 2: 2 potential-free contacts,max. contact load:3  ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5  ADC-13 at 30  VDC Connection EthernetRJ-45 AS-Interfacespring terminals, removable Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Machinery Directive Directive 2006/42/ECEN 61508-1:2010 EN/ISO 13849-1:2008 EN 62061:2005 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 EN 61326-3-1:2008 IEC 61508:2010 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Material HousingStainless steel Mass800 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121004 Datasheet excerpt: Technical data of  VBG-ENX-K30-DMD-S16-EV Product Description EtherNet/IP + Modbus TCP Gateway with integrated safety monitor, double master for 2 AS-Interface networks, power supply input with data decoupling General specifications AS-Interface specificationV3.0 PLC-Functionalityactivateable Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display Data decouplingintegrated Switch-on delay< 10 s Response delay< 40 ms UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e MTTFd200 a B10d2 E+7 Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED ETHERNETethernet active; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED EDM/StartExternal device monitoring circuit inputs closed, 4x yellow LEDs LED output circuitOutput circuit closed; 4 x green LEDs Button4 Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltage26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC Rated operating current≤ 300 mA from AS-Interface Power supplymax. 4 A per AS-Interface circuit Interface 1 Interface type2 x RJ-45 ProtocolEtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3 supports device level ring protocol DLR Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection Interface 2 Interface typeEthernet: RJ-45 Diagnostic Interface Transfer rate10 MBit/s Interface 3 Interface typeChip card slot Input Number/Type4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) Output Safety outputOutput circuits 1 and 2: 2 potential-free contacts,max. contact load:3  ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5  ADC-13 at 30  VDC Connection EthernetRJ-45 AS-Interfacespring terminals, removable Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Machinery Directive Directive 2006/42/ECEN 61508-1:2010 EN/ISO 13849-1:2008 EN 62061:2005 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Shock resistanceEN 61131-2:2004 StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 EN 61326-3-1:2008 IEC 61508:2010 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Material HousingStainless steel Mass800 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121004

Unser Unternehmen Bewertungen