VBG-PN-K20-DMD-EV2 PEPPERL+FUCHS - Part number: 281191
auf Anfrage erhältlich

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

VBG-PN-K20-DMD-EV2 PEPPERL+FUCHS - Part number: 281191

PEPPERL+FUCHS

AS-Interface gateway VBG-PN-K20-DMD-EV2 VBG-PN-K20-DMD-EV2 Connection to PROFINET IO Dublicate addressing detection Earth fault detection AS-Interface noise detection 2 AS-Interface networks Integrated web server with extended functionality Integrated switch allows line topology AS-Interface gateway VBG-PN-K20-DMD-EV2 VBG-PN-K20-DMD-EV2 Connection to PROFINET IO Dublicate addressing detection Earth fault detection AS-Interface noise detection 2 AS-Interface networks Integrated web server with extended functionality Integrated switch allows line topology

MPNs 281191, PEP281191, VBG-PN-K20-DMD-EV2
HS-Code 85176900
Weight 0.5 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

auf Anfrage erhältlich

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  VBG-PN-K20-DMD-EV2 Product Description PROFINET Gateway, double master for 2 AS-Interface networks with integrated switch General specifications AS-Interface specificationV3.0 Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED ETHERNETethernet active; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green Button4 Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 250 mA PELV Interface 1 Interface typePROFINET I / O device (IRT) Physical 2 x RJ-45 ProtocolMedia Redundancy Protocol (MRP) Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection Interface 2 Interface typeChip card slot Connection PROFINETRJ-45 AS-Interfaceremovable spring clamp terminals Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Material HousingStainless steel Mass500 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBG-PN-K20-DMD-EV2 Product Description PROFINET Gateway, double master for 2 AS-Interface networks with integrated switch General specifications AS-Interface specificationV3.0 Duplicate address detectionfrom AS-Interface slaves Earth fault detectionintegrated EMC monitoringintegrated Diagnostics functionExtended function via display UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source Indicators/operating means DisplayIlluminated graphical LC display for addressing and error messages LED ETHERNETethernet active; LED green LED AS-i ACTIVEAS-Interface operation normal; LED green LED CONFIG ERRconfiguration error; LED red LED PRG ENABLEautom. programming; LED green LED POWERvoltage ON; LED green LED PRJ MODEprojecting mode active; LED yellow LED U AS-iAS-Interface voltage; LED green Button4 Switch SETSelection and setting of a slave address OK buttonMode selection traditional-graphical/confirmation Button MODEMode selection PRJ-operation/save configuration/cursor ESC buttonMode selection traditional-graphical/cancel Electrical specifications Insulation voltage≥ 500 V Rated operating voltagefrom AS-Interface Rated operating current≤ 250 mA PELV Interface 1 Interface typePROFINET I / O device (IRT) Physical 2 x RJ-45 ProtocolMedia Redundancy Protocol (MRP) Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection Interface 2 Interface typeChip card slot Connection PROFINETRJ-45 AS-Interfaceremovable spring clamp terminals Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007 Degree of protectionEN 60529:2000 AS-InterfaceEN 62026-2:2013 Approvals and certificates UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Material HousingStainless steel Mass500 g Construction typeLow profile housing , Stainless steel Classifications SystemClasscode ECLASS 11.027242607 ECLASS 10.0.127242607 ECLASS 9.027242607 ECLASS 8.027242607 ECLASS 5.127242607 ETIM 8.0EC001603 ETIM 7.0EC001603 ETIM 6.0EC001603 ETIM 5.0EC001603 UNSPSC 12.139121535

Unser Unternehmen Bewertungen