VAA-2E2A-CB10-SJ/E2J-FL PEPPERL+FUCHS - Part number: 70104166
Ausverkauft - Auftragsrückstand
Beim Hersteller zu bestellen
179,07 USD

Importsteuern ausgeschlossen

bitte einloggen

VAA-2E2A-CB10-SJ/E2J-FL PEPPERL+FUCHS - Part number: 70104166

PEPPERL+FUCHS

AS-Interface safety module VAA-2E2A-CB10-SJ/E2J-FL VAA-2E2A-CB10-SJ/E2J-FL Connection of contact safety switches, e.g. EMERGENCY STOP button Applications up to Cat. 4, PLe / SIL3 Modular safety solution Ultra-compact enclosure AS-Interface safety module VAA-2E2A-CB10-SJ/E2J-FL VAA-2E2A-CB10-SJ/E2J-FL Connection of contact safety switches, e.g. EMERGENCY STOP button Applications up to Cat. 4, PLe / SIL3 Modular safety solution Ultra-compact enclosure

MPNs 70104166, PEP70104166, VAA-2E2A-CB10-SJ/E2J-FL
HS-Code 85371091
Weight N/A

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

179,07 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  VAA-2E2A-CB10-SJ/E2J-FL Product Description CB10 safety module, 2 safety-related inputs and 2 conventional electronic outputs General specifications Node typeSafety-Slave AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0 LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED INswitching state (input); 2 LED yellow LED OUTSwitching state (output); 2 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV) Rated operating current≤ 40 mA (without inputs/outputs)/max. 160 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Rated insulation voltage32 V Pulse withstand voltage0.8 kV Input Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: Up to category 2/PLc in accordance with ISO 13849-1 or SIL 1 in accordance with IEC 62061 1 two-channel contact: Up to category 4/PLe in accordance with ISO 13849-1 or SIL 3 in accordance with IEC 62061 Supplyfrom AS-Interface Voltage20 ... 30 V DC pulsed Currentinput current limited ≤ 15 mA,short-circuit protected Output Number/Type2 conventional electronic outputs, PNP , overload and short-circuit resistant Supplyfrom AS-Interface Voltage(UASI - 7.0 V) ≤ UOUT ≤ UASI Current≤ 100 mA per output, ≤ 100 mA total Directive conformity Electromagnetic compatibility Directive 2014/30/EUIEC 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 EN 61326-1:2013 Machinery Directive Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Electrical safetyIEC 61140:2009 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityIEC 62026-2:2013 EN 61326-3-1:2017 EN 61000-6-2:2005 Functional safetyEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 Programming instructions ProfileS-7.B IO code7 ID codeB ID1 codeF ID2 code0 Data bits (function via AS-Interface) input output D0 dyn. safety code 1 OUT 1 D1 dyn. safety code 1 OUT 2 D2 dyn. safety code 2 - D3 dyn. safety code 2 - Parameter bits (programmable via AS-i)function P0not used P1not used P2not used P3not used Approvals and certificates UL approvalProtection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs. Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 5000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 according to EN 60529 Connection200 mm, PVC cable 0.5 mm2 Material Contactsopen conductor ends with connector sleeves HousingPolyamide hot-melt adhesive Mass31 g NoteThis device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired. Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-2E2A-CB10-SJ/E2J-FL Product Description CB10 safety module, 2 safety-related inputs and 2 conventional electronic outputs General specifications Node typeSafety-Slave AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0 LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED INswitching state (input); 2 LED yellow LED OUTSwitching state (output); 2 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV) Rated operating current≤ 40 mA (without inputs/outputs)/max. 160 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Rated insulation voltage32 V Pulse withstand voltage0.8 kV Input Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: Up to category 2/PLc in accordance with ISO 13849-1 or SIL 1 in accordance with IEC 62061 1 two-channel contact: Up to category 4/PLe in accordance with ISO 13849-1 or SIL 3 in accordance with IEC 62061 Supplyfrom AS-Interface Voltage20 ... 30 V DC pulsed Currentinput current limited ≤ 15 mA,short-circuit protected Output Number/Type2 conventional electronic outputs, PNP , overload and short-circuit resistant Supplyfrom AS-Interface Voltage(UASI - 7.0 V) ≤ UOUT ≤ UASI Current≤ 100 mA per output, ≤ 100 mA total Directive conformity Electromagnetic compatibility Directive 2014/30/EUIEC 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 EN 61326-1:2013 Machinery Directive Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Electrical safetyIEC 61140:2009 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityIEC 62026-2:2013 EN 61326-3-1:2017 EN 61000-6-2:2005 Functional safetyEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 Programming instructions ProfileS-7.B IO code7 ID codeB ID1 codeF ID2 code0 Data bits (function via AS-Interface) input output D0 dyn. safety code 1 OUT 1 D1 dyn. safety code 1 OUT 2 D2 dyn. safety code 2 - D3 dyn. safety code 2 - Parameter bits (programmable via AS-i)function P0not used P1not used P2not used P3not used Approvals and certificates UL approvalProtection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs. Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 5000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 according to EN 60529 Connection200 mm, PVC cable 0.5 mm2 Material Contactsopen conductor ends with connector sleeves HousingPolyamide hot-melt adhesive Mass31 g NoteThis device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired. Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Unser Unternehmen Bewertungen