VAA-4E4A-KE1-Z/E2 PEPPERL+FUCHS - Part number: 186880
Ausverkauft - Auftragsrückstand
Beim Hersteller zu bestellen
275,68 USD

Importsteuern ausgeschlossen

bitte einloggen

VAA-4E4A-KE1-Z/E2 PEPPERL+FUCHS - Part number: 186880

PEPPERL+FUCHS

AS-Interface sensor/actuator module VAA-4E4A-KE1-Z/E2 VAA-4E4A-KE1-Z/E2 Housing with removable terminals Communication monitoring Inputs for 2-wire sensors and mechanical contacts Addressing jack Power supply of the inputs and outputs from the external auxiliary voltage Function display for bus, ext. auxiliary voltage, inputs and outputs AS-Interface sensor/actuator module VAA-4E4A-KE1-Z/E2 VAA-4E4A-KE1-Z/E2 Housing with removable terminals Communication monitoring Inputs for 2-wire sensors and mechanical contacts Addressing jack Power supply of the inputs and outputs from the external auxiliary voltage Function display for bus, ext. auxiliary voltage, inputs and outputs

MPNs 186880, PEP186880, VAA-4E4A-KE1-Z/E2
HS-Code 85371091
Weight N/A

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

275,68 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  VAA-4E4A-KE1-Z/E2 Product Description KE1 switch cabinet module4 inputs and 4 outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE87056 Functional safety related parameters MTTFd90 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts Supplyfrom external auxiliary voltage UAUX Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current0.5 A per output , 2 A per module Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUIEC 62026-2:2015 EN 61326-1:2006 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2015 Emitted interferenceEN 55011:2009 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61326-1:2006 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity90 % , noncondensing Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable spring double terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2recommended tools for 1.5 mm2: PxC CRIMPFOX ZA3 or Weidmüller PZ 6 roto Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-4E4A-KE1-Z/E2 Product Description KE1 switch cabinet module4 inputs and 4 outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE87056 Functional safety related parameters MTTFd90 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts Supplyfrom external auxiliary voltage UAUX Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current0.5 A per output , 2 A per module Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUIEC 62026-2:2015 EN 61326-1:2006 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2015 Emitted interferenceEN 55011:2009 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61326-1:2006 Programming instructions ProfileS-7.0 IO code7 ID code0 ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity90 % , noncondensing Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable spring double terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2recommended tools for 1.5 mm2: PxC CRIMPFOX ZA3 or Weidmüller PZ 6 roto Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Unser Unternehmen Bewertungen