VBA-4E2A-KE1-Z/E2 PEPPERL+FUCHS - Part number: 117993
Ausverkauft - Auftragsrückstand
Beim Hersteller zu bestellen
271,04 USD

Importsteuern ausgeschlossen

bitte einloggen

VBA-4E2A-KE1-Z/E2 PEPPERL+FUCHS - Part number: 117993

PEPPERL+FUCHS

AS-Interface sensor/actuator module VBA-4E2A-KE1-Z/E2 VBA-4E2A-KE1-Z/E2 A/B node with extended addressing possibility for up to 62 nodes Housing with removable terminals Communication monitoring Inputs for 2-wire sensors and mechanical contacts Addressing jack Power supply of outputs from the external auxiliary voltage Power supply of inputs from the module Function display for bus, ext. auxiliary voltage, inputs and outputs AS-Interface sensor/actuator module VBA-4E2A-KE1-Z/E2 VBA-4E2A-KE1-Z/E2 A/B node with extended addressing possibility for up to 62 nodes Housing with removable terminals Communication monitoring Inputs for 2-wire sensors and mechanical contacts Addressing jack Power supply of outputs from the external auxiliary voltage Power supply of inputs from the module Function display for bus, ext. auxiliary voltage, inputs and outputs

MPNs 117993, PEP117993, VBA-4E2A-KE1-Z/E2
HS-Code 85371091
Weight N/A

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

271,04 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  VBA-4E2A-KE1-Z/E2 Product Description KE1 switch cabinet module4 inputs and 2 outputs General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE87056 Functional safety related parameters MTTFd270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 2 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 25 mA (without sensors) / max. 60 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts Supplyfrom AS-Interface Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type2 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) CurrentO1/O2 max. 1.5 A, total 3 A (TB ≤ 40 °C)O1/O2 max. 1 A, total 2 A (TB ≤ 70 °C) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2001 Programming instructions ProfileS-7.A.0 IO code7 ID codeA ID1 code7 ID2 code0 Data bits (function via AS-Interface)InputOutput D0 IN1 O1 D1 IN2 O2 D2 IN3 - D3 IN4 - Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity90 % , noncondensing Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E2A-KE1-Z/E2 Product Description KE1 switch cabinet module4 inputs and 2 outputs General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE87056 Functional safety related parameters MTTFd270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 2 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 25 mA (without sensors) / max. 60 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts Supplyfrom AS-Interface Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type2 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) CurrentO1/O2 max. 1.5 A, total 3 A (TB ≤ 40 °C)O1/O2 max. 1 A, total 2 A (TB ≤ 70 °C) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2001 Programming instructions ProfileS-7.A.0 IO code7 ID codeA ID1 code7 ID2 code0 Data bits (function via AS-Interface)InputOutput D0 IN1 O1 D1 IN2 O2 D2 IN3 - D3 IN4 - Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity90 % , noncondensing Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Unser Unternehmen Bewertungen