Inductive sensor NCB2-V3-N0 NCB2-V3-N0 2 mm flush Usable up to SIL 2 acc. to IEC 61508 NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor NCB2-V3-N0 NCB2-V3-N0 2 mm flush Usable up to SIL 2 acc. to IEC 61508 NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70133083, PEP70133083, NCB2-V3-N0
HS-Code 85365090
Weight N/A

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

87,23 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Nach Vereinigte Staaten ab 27,36 USD von DHL Express Worldwide
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

6 Erhältlich bei den Partnern Preis und Lieferzeit auf Anfrage
bitte einloggen

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  NCB2-V3-N0 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance2 mm Installationflush Assured operating distance0 ... 1.62 mm Reduction factor rAl 0.3 Reduction factor rCu 0.2 Reduction factor r304 0.7 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 2000 Hz Hysteresistyp. 3 % Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Switching state indicatorLED, yellow Functional safety related parameters Safety Integrity Level (SIL)SIL 2 MTTFd2180 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X Equipment protection level MbIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X EAC conformityTR CU 012/2011 UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002302 NEPSI approval NEPSI certificateGYJ16.1394X ANZEx19.3001X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typecable Housing materialPBT Sensing facePBT Degree of protectionIP67 Cable Cable diameter2.6 mm ± 0.2 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length130 mm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NCB2-V3-N0 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance2 mm Installationflush Assured operating distance0 ... 1.62 mm Reduction factor rAl 0.3 Reduction factor rCu 0.2 Reduction factor r304 0.7 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 2000 Hz Hysteresistyp. 3 % Current consumption Measuring plate not detected≥ 3 mA Measuring plate detected≤ 1 mA Switching state indicatorLED, yellow Functional safety related parameters Safety Integrity Level (SIL)SIL 2 MTTFd2180 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibilityNE 21:2007 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X Equipment protection level MbIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X EAC conformityTR CU 012/2011 UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002302 NEPSI approval NEPSI certificateGYJ16.1394X ANZEx19.3001X Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typecable Housing materialPBT Sensing facePBT Degree of protectionIP67 Cable Cable diameter2.6 mm ± 0.2 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length130 mm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550

Unser Unternehmen Bewertungen