Inductive sensor NJ4-30GM-N-200 NJ4-30GM-N-200 4 mm flush Temperature range0 ... 200 °C (0 ... 392 °F) NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor NJ4-30GM-N-200 NJ4-30GM-N-200 4 mm flush Temperature range0 ... 200 °C (0 ... 392 °F) NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70133020, PEP70133020, NJ4-30GM-N-200
HS-Code 85365090
Weight N/A

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

1.406,12 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  NJ4-30GM-N-200 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance4 mm Installationflush Assured operating distance0 ... 3.04 mm Reduction factor rAl 0.15 Reduction factor rCu 0.05 Reduction factor r304 0.55 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 1000 Hz Hysteresis≤ 20 % at 200°C Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detectedmin. 3 mA Measuring plate detected≤ 1 mA Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0037X Equipment protection level GbIECEx PTB 11.0037X Equipment protection level DaIECEx PTB 11.0037X Equipment protection level MbIECEx PTB 11.0037X ATEX approval Equipment protection level GaPTB 00 ATEX 2048 X Equipment protection level GbPTB 00 ATEX 2048 X Equipment protection level DaPTB 00 ATEX 2048 X UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0452 CCC approval Hazardous Location2020322315002257 NEPSI approval NEPSI certificateGYJ16.1393X ANZEx18.3018X Ambient conditions Ambient temperature0 ... 200 °C (32 ... 392 °F) Mechanical specifications Connection typecable Housing materialStainless steel 1.4305 / AISI 303 Sensing facePPS Degree of protectionIP65 Cable Cable diameter4 mm ± 0.2 mm Bending radius> 7.5 x cable diameter MaterialFEP Core cross section0.34 mm2 Length5 m Noteamplifier -25°C...70°C 2 m PTFE cable between amplifier and oscillator General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 Datasheet excerpt: Technical data of  NJ4-30GM-N-200 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance4 mm Installationflush Assured operating distance0 ... 3.04 mm Reduction factor rAl 0.15 Reduction factor rCu 0.05 Reduction factor r304 0.55 Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 1000 Hz Hysteresis≤ 20 % at 200°C Suitable for 2:1 technologyyes , Reverse polarity protection diode not required Current consumption Measuring plate not detectedmin. 3 mA Measuring plate detected≤ 1 mA Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0037X Equipment protection level GbIECEx PTB 11.0037X Equipment protection level DaIECEx PTB 11.0037X Equipment protection level MbIECEx PTB 11.0037X ATEX approval Equipment protection level GaPTB 00 ATEX 2048 X Equipment protection level GbPTB 00 ATEX 2048 X Equipment protection level DaPTB 00 ATEX 2048 X UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0452 CCC approval Hazardous Location2020322315002257 NEPSI approval NEPSI certificateGYJ16.1393X ANZEx18.3018X Ambient conditions Ambient temperature0 ... 200 °C (32 ... 392 °F) Mechanical specifications Connection typecable Housing materialStainless steel 1.4305 / AISI 303 Sensing facePPS Degree of protectionIP65 Cable Cable diameter4 mm ± 0.2 mm Bending radius> 7.5 x cable diameter MaterialFEP Core cross section0.34 mm2 Length5 m Noteamplifier -25°C...70°C 2 m PTFE cable between amplifier and oscillator General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714

Unser Unternehmen Bewertungen