Inductive sensor NSB5-18GH50-2E2-S2D2 NSB5-18GH50-2E2-S2D2 No unusable area 5 mm flush Use of standard metallic actuating surfaces Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3) LED for switching state and fault indication Safety outputs OSSD TÜV certified high-grade steel housing V4A/316L Inductive sensor NSB5-18GH50-2E2-S2D2 NSB5-18GH50-2E2-S2D2 No unusable area 5 mm flush Use of standard metallic actuating surfaces Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3) LED for switching state and fault indication Safety outputs OSSD TÜV certified high-grade steel housing V4A/316L

MPNs 304276-000024, PEP304276-000024, NSB5-18GH50-2E2-S2D2
HS-Code 85365090
Weight N/A

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

181,30 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  NSB5-18GH50-2E2-S2D2 General specifications Switching function2 x normally open (NO) Output typePNP Rated operating distance5 mm Installationflush Output polarityDC Assured operating distance0 ... 4.05 mm Actuating elementReference target according EN IEC 60947-5-2 (FE360 - ST37K) 18 mm x 18 mm x 1 mm Reduction factor rAl 0.5 Reduction factor rCu 0.4 Reduction factor r304 0.85 Reduction factor rBrass 0.55 Output type4-wire Nominal ratings Operating voltage18 ... 30 V Rated operating voltage24 V Switching frequency0 ... 30 Hz Hysteresistyp. 5% Reverse polarity protectionreverse polarity protected Short-circuit protectionpulsing Overload resistanceyes Voltage drop≤ 3 V at IL (sum of all outputs) max. 50 mA Rated insulation voltage30 V Operating current1 ... 30 mA per output Off-state current0 ... 0.5 mA No-load supply current≤ 15 mA Time delay before availability≤ 300 ms Switching state indicatorLED, yellow Error indicatorLED, red Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Performance level (PL)PL d CategoryCat. 2 MTTFd> 7500 a Mission Time (TM)20 a Diagnostic Coverage (DC)min. 60 % Assured release distance of a PDDB7.5 mm Compliance with standards and directives Standard conformity StandardsEN IEC 60947-5-2:2007 EN IEC 60947-5-3:2013 EN ISO 13849-1:2015 EN IEC 61508:2010 EN 62061:2005+AC:2010+A1:2013+A2:2015 compatible with EN ISO 61131-2:2007 Typ 1, 2, 3 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalcULus Listed, General Purpose, Class 2 Power Source CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Altitude≤ 2000 m above MSL Mechanical specifications Connection typecable PVC , 2 m Core cross section0.34 mm2 Housing materialStainless steel 1.4404 / AISI 316L Sensing facePBT Degree of protectionIP68 / IP69 Mass92 g General information Scope of deliverySupplied with 2 nuts Classifications SystemClasscode ECLASS 11.027272401 ECLASS 10.0.127272401 ECLASS 9.027272401 ECLASS 8.027272401 ECLASS 5.127272401 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NSB5-18GH50-2E2-S2D2 General specifications Switching function2 x normally open (NO) Output typePNP Rated operating distance5 mm Installationflush Output polarityDC Assured operating distance0 ... 4.05 mm Actuating elementReference target according EN IEC 60947-5-2 (FE360 - ST37K) 18 mm x 18 mm x 1 mm Reduction factor rAl 0.5 Reduction factor rCu 0.4 Reduction factor r304 0.85 Reduction factor rBrass 0.55 Output type4-wire Nominal ratings Operating voltage18 ... 30 V Rated operating voltage24 V Switching frequency0 ... 30 Hz Hysteresistyp. 5% Reverse polarity protectionreverse polarity protected Short-circuit protectionpulsing Overload resistanceyes Voltage drop≤ 3 V at IL (sum of all outputs) max. 50 mA Rated insulation voltage30 V Operating current1 ... 30 mA per output Off-state current0 ... 0.5 mA No-load supply current≤ 15 mA Time delay before availability≤ 300 ms Switching state indicatorLED, yellow Error indicatorLED, red Functional safety related parameters Safety Integrity Level (SIL)SIL 2 Performance level (PL)PL d CategoryCat. 2 MTTFd> 7500 a Mission Time (TM)20 a Diagnostic Coverage (DC)min. 60 % Assured release distance of a PDDB7.5 mm Compliance with standards and directives Standard conformity StandardsEN IEC 60947-5-2:2007 EN IEC 60947-5-3:2013 EN ISO 13849-1:2015 EN IEC 61508:2010 EN 62061:2005+AC:2010+A1:2013+A2:2015 compatible with EN ISO 61131-2:2007 Typ 1, 2, 3 Approvals and certificates EAC conformityTR CU 020/2011 UL approvalcULus Listed, General Purpose, Class 2 Power Source CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Altitude≤ 2000 m above MSL Mechanical specifications Connection typecable PVC , 2 m Core cross section0.34 mm2 Housing materialStainless steel 1.4404 / AISI 316L Sensing facePBT Degree of protectionIP68 / IP69 Mass92 g General information Scope of deliverySupplied with 2 nuts Classifications SystemClasscode ECLASS 11.027272401 ECLASS 10.0.127272401 ECLASS 9.027272401 ECLASS 8.027272401 ECLASS 5.127272401 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550