USi-safety evaluation unit USI-F262-2E5-V19-S2D3 USI-F262-2E5-V19-S2D3 Categorie 3 PL d (EN ISO 13849) for each ultrasonic transducer without redundancy Multiple device installation possible, no mutual interference (no cross-talk) Safety outputs OSSD Adjustable sound cone Temperature compensation Parameterization, commissioning and reporting via USi-safety parameterization software USi-safety evaluation unit USI-F262-2E5-V19-S2D3 USI-F262-2E5-V19-S2D3 Categorie 3 PL d (EN ISO 13849) for each ultrasonic transducer without redundancy Multiple device installation possible, no mutual interference (no cross-talk) Safety outputs OSSD Adjustable sound cone Temperature compensation Parameterization, commissioning and reporting via USi-safety parameterization software

MPNs 70131322, PEP70131322, USI-F262-2E5-V19-S2D3
HS-Code 90318000
Weight 0.45 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

1.500,55 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  USI-F262-2E5-V19-S2D3 Product Description Evaluation unit exclusively for the ultrasonic sensor system USi-safety General specifications TypeUSi-safety evaluation unit Sensing range1 ... 250 cm typ. 200 cm Adjustment range1 ... 250 cm Dead band1 cm Object sizetyp. ∅ 1 cm Transducer frequencytyp. 103 kHz Resolution1 cm Target velocityaxial (max.): typ. 2 m/s (up to 2.5 m/s) Repeat accuracy± 0 cm Hysteresistyp. 0 cm (0 up to SP1/10) Temperature influenceautomatic or manual temperature compensation available , without temperature compensation: 0.17 %/K Functional safety related parameters Performance level (PL)PL d CategoryCat. 3 Reaction timetyp. 100 ms ( 99 ... 660 ms ) Recovery timetyp. 990 ms ( 330 ... 3300 ms ) MTTFd316 a Diagnostic Coverage (DC)87 % Electrical specifications Fusing2 A , slow Operating voltage21 ... 28 V DC typ. 24 V DC No-load supply current≤ 150 mA Power consumptionmax. 3.6 W Interface Interface typeUSB 2.0 Inputs Input type2 inputs for ultrasonic transducers 1 input for temperature sensor Output 1 Output typesafety output OSSD Normally closed, Power FET PNP OSSD 1.1 and OSSD 1.2 Switching voltagemax. UB Switching current150 mA per output Output 2 Output typesafety output OSSD Normally closed, Power FET PNP OSSD 2.1 and OSSD 2.2 Switching current150 mA per output Output 3 Output typeNormally open/normally closed switchable, Power FET PNP signal output OUT1 Switching voltagemax. UB Switching current150 mA Output 4 Output typeNormally open/normally closed switchable, Power FET PNP signal output OUT2 Switching voltagemax. UB Switching current150 mA Compliance with standards and directives Standard conformity StandardsIEC 60947-5-2 IEC 60204-1 EN ISO 13849 IEC 61326-3-1:2007 IEC/CISPR 11 group 1, class A Approvals and certificates CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-30 ... 50 °C (-22 ... 122 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Connection typeConnector plug Degree of protectionIP65 Connectionfor power supply and outputs: connector plug M12, 8-pin, connection line max. 30 m for temperature sensor: socket M8, 6-pin for ultrasonic transducer: for each socket M8, 3-pin for parameterization: socket Mini USB Material Housingdiecast aluminum Mass450 g Factory settings Default settingSee the original instructions Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960 Datasheet excerpt: Technical data of  USI-F262-2E5-V19-S2D3 Product Description Evaluation unit exclusively for the ultrasonic sensor system USi-safety General specifications TypeUSi-safety evaluation unit Sensing range1 ... 250 cm typ. 200 cm Adjustment range1 ... 250 cm Dead band1 cm Object sizetyp. ∅ 1 cm Transducer frequencytyp. 103 kHz Resolution1 cm Target velocityaxial (max.): typ. 2 m/s (up to 2.5 m/s) Repeat accuracy± 0 cm Hysteresistyp. 0 cm (0 up to SP1/10) Temperature influenceautomatic or manual temperature compensation available , without temperature compensation: 0.17 %/K Functional safety related parameters Performance level (PL)PL d CategoryCat. 3 Reaction timetyp. 100 ms ( 99 ... 660 ms ) Recovery timetyp. 990 ms ( 330 ... 3300 ms ) MTTFd316 a Diagnostic Coverage (DC)87 % Electrical specifications Fusing2 A , slow Operating voltage21 ... 28 V DC typ. 24 V DC No-load supply current≤ 150 mA Power consumptionmax. 3.6 W Interface Interface typeUSB 2.0 Inputs Input type2 inputs for ultrasonic transducers 1 input for temperature sensor Output 1 Output typesafety output OSSD Normally closed, Power FET PNP OSSD 1.1 and OSSD 1.2 Switching voltagemax. UB Switching current150 mA per output Output 2 Output typesafety output OSSD Normally closed, Power FET PNP OSSD 2.1 and OSSD 2.2 Switching current150 mA per output Output 3 Output typeNormally open/normally closed switchable, Power FET PNP signal output OUT1 Switching voltagemax. UB Switching current150 mA Output 4 Output typeNormally open/normally closed switchable, Power FET PNP signal output OUT2 Switching voltagemax. UB Switching current150 mA Compliance with standards and directives Standard conformity StandardsIEC 60947-5-2 IEC 60204-1 EN ISO 13849 IEC 61326-3-1:2007 IEC/CISPR 11 group 1, class A Approvals and certificates CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-30 ... 50 °C (-22 ... 122 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Connection typeConnector plug Degree of protectionIP65 Connectionfor power supply and outputs: connector plug M12, 8-pin, connection line max. 30 m for temperature sensor: socket M8, 6-pin for ultrasonic transducer: for each socket M8, 3-pin for parameterization: socket Mini USB Material Housingdiecast aluminum Mass450 g Factory settings Default settingSee the original instructions Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960