PEPPERL+FUCHS

Timer, Counter, Tachometer KC-LCDC-48-2R-230VAC KC-LCDC-48-2R-230VAC Counter/Timer/Tachometer Adding/subtracting via 2 separate inputs Batch controller with 2 pre-selections Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs Multicolor display Display range and preselection range from -999999 up to 999999Overflow will be evaluated correctly up to 1 decade PNP and NPN sensors can be connected Degree of protection IP65 (front only) Timer, Counter, Tachometer KC-LCDC-48-2R-230VAC KC-LCDC-48-2R-230VAC Counter/Timer/Tachometer Adding/subtracting via 2 separate inputs Batch controller with 2 pre-selections Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs Multicolor display Display range and preselection range from -999999 up to 999999Overflow will be evaluated correctly up to 1 decade PNP and NPN sensors can be connected Degree of protection IP65 (front only)

MPNs 214740, PEP214740, KC-LCDC-48-2R-230VAC
HS-Code 90262000
Weight 0.14 kg

Das Produktbild dient nur zur Veranschaulichung.
Das Ursprungsland, der HS-Code und die Beschreibung werden vom Hersteller angegeben und können ohne vorherige Ankündigung geändert werden. Aus diesem Grund kann PLC-City nicht für Abweichungen verantwortlich gemacht werden.
Von PLC-CITY® verkauft und aus Italien versandt

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

425,17 USD

Importsteuern ausgeschlossen

bitte einloggen
Von PLC-CITY® verkauft und aus Italien versandt
Wir sind ein Spezialpartner von PEPPERL+FUCHS
Kostenloser Expressversand nach Vereinigte Staaten
Loader...
Alle Versanddienste anzeigen
Fordern Sie ein Angebot an, um das Lieferdatum zu kennen

Wir akzeptieren viele Zahlungsmethoden: Banküberweisung (SEPA, ACH), Debit/ Kreditkarten (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, Link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay Deal, Przelewy24, WeChatPay.
Weitere Informationen zu unseren Zahlungsmethoden

Dieses Produkt ist durch eine 12 Monaten Garantie abgedeckt, gültig für Herstellungsfehler oder Fehlfunktionen. Die Garantie deckt keine Schäden ab, die durch unsachgemäßen Gebrauch oder versehentliche Beschädigung verursacht wurden.
Erfahren Sie mehr über unsere Garantie

Rückgaben bedürfen einer vorherigen Genehmigung und werden als Store-Gutschrift erstattet. Vorbestellte Artikel sind ausgeschlossen.

Sehen Sie sich unsere Rückgabebedingungen an

Holen Sie sich jetzt Ihr persönliches Angebot

Ein engagierter Vertriebsmitarbeiter hilft Ihnen, den besten Preis und die beste Lieferzeit anzubieten.

bitte einloggen

Fordern Sie Ihren maßgeschneiderten technischen Service an

Verlassen Sie sich auf unser fachkundiges technisches Team für eine Reihe von personalisierten Dienstleistungen: Reparatur, Programmierung, Wartung und vieles mehr.

Produktinformationen

Beschreibung

Datasheet excerpt: Technical data of  KC-LCDC-48-2R-230VAC Product Description LCD batch controller with 2 relay outputs and 90 ... 260 VAC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing90 … 260 V AC: T 0.1 A Operating voltage90 ... 260 V AC Power consumptionmax. 8 VA Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High12 ... 30 V DC Low0 ... 4 V DC Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Relaychangeover contact , Make contact Switching voltagemax. 250 V AC / 110 V DC Switching currentmax. 3 A AC/DC, min. 30 mA DC, Switching powermax. 750 VA / 90 W Sensor supply20.4 ... 27.6 V DC, max. 80 mA Output IRelay with make contact, NC or NO progr. Mechanical life2 x 107 switching cycles Electrical life1 x 105 switching cycles at 3 A Output IIRelay with changeover contact Mechanical life2 x 107 switching cycles Electrical life5 x 104 cycles at 3 A Response timeRelay: 7 ms Frequency counter: 100/600 ms Compliance with standards and directives Directive conformity Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2 EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C (noncondensing) Altitude0 ... 2000 m Pollution degree2 Mechanical specifications Degree of protectionIP65 (front) Mass142 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902 Datasheet excerpt: Technical data of  KC-LCDC-48-2R-230VAC Product Description LCD batch controller with 2 relay outputs and 90 ... 260 VAC supply voltage General specifications Pre-selection2-fold Data storage> 10 years, EEPROM Programmingkeypad-driven menu Functional safety related parameters MTTFd410 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Indicators/operating means Type2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit Display valuedigit height 9 mm Pre-selectiondigit height 7 mm Key interlockvia "high" potential at "LOCK" input Decimal point0 to max 5 fractional digits Scale factor0.0001 ... 99.9999 Resetmanually or external Electrical specifications Fusing90 … 260 V AC: T 0.1 A Operating voltage90 ... 260 V AC Power consumptionmax. 8 VA Input ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI Signal voltage High12 ... 30 V DC Low0 ... 4 V DC Counting frequency30 Hz / 55 kHz Minimum pulse durationControl/reset inputs: 10 ms / 1 ms Impedance5 kOhm Count modes Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%  Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) Output Relaychangeover contact , Make contact Switching voltagemax. 250 V AC / 110 V DC Switching currentmax. 3 A AC/DC, min. 30 mA DC, Switching powermax. 750 VA / 90 W Sensor supply20.4 ... 27.6 V DC, max. 80 mA Output IRelay with make contact, NC or NO progr. Mechanical life2 x 107 switching cycles Electrical life1 x 105 switching cycles at 3 A Output IIRelay with changeover contact Mechanical life2 x 107 switching cycles Electrical life5 x 104 cycles at 3 A Response timeRelay: 7 ms Frequency counter: 100/600 ms Compliance with standards and directives Directive conformity Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2 EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Standard conformity Emitted interferenceDIN EN 55011:2009, Class B Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Ambient conditions Ambient temperature-20 ... 65 °C (-4 ... 149 °F) Storage temperature-25 ... 75 °C (-13 ... 167 °F) Relative humidity≤ 93 % at 40 °C (noncondensing) Altitude0 ... 2000 m Pollution degree2 Mechanical specifications Degree of protectionIP65 (front) Mass142 g Dimensions48 mm x 48 mm x 109.8 mm Classifications SystemClasscode ECLASS 11.027210301 ECLASS 10.0.127210301 ECLASS 9.027210301 ECLASS 8.027210301 ECLASS 5.127210301 ETIM 8.0EC002300 ETIM 7.0EC002300 ETIM 6.0EC002300 ETIM 5.0EC000677 UNSPSC 12.141111902