VBA-2E-KE5-IJL/UJL PEPPERL+FUCHS - Part number: 288595
Não disponível em stock - Por encomenda
Para encomendar ao fabricante
424,40 USD

Impostos de importação excluídos

Tens de ter sessão iniciada

VBA-2E-KE5-IJL/UJL PEPPERL+FUCHS - Part number: 288595

PEPPERL+FUCHS

AS-Interface analog module VBA-2E-KE5-IJL/UJL VBA-2E-KE5-IJL/UJL Housing with push-in connection technology and mechanically coded terminal blocks Housing width 19 mm, installation in the switch cabinet on DIN mounting rail Sensors can be supplied either from the AS-Interface or external auxiliary voltage, as preferred Function indicator for the bus, external auxiliary voltage, internal sensor supply, and inputs AS-Interface analog module VBA-2E-KE5-IJL/UJL VBA-2E-KE5-IJL/UJL Housing with push-in connection technology and mechanically coded terminal blocks Housing width 19 mm, installation in the switch cabinet on DIN mounting rail Sensors can be supplied either from the AS-Interface or external auxiliary voltage, as preferred Function indicator for the bus, external auxiliary voltage, internal sensor supply, and inputs

MPNs 288595, PEP288595, VBA-2E-KE5-IJL/UJL
Código HS 85371091
Weight 0.11 kg

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

424,40 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  VBA-2E-KE5-IJL/UJL Product Description Switch cabinet module2 analog Inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 MTBF154 a Indicators/operating means LED FAULTFault indication: red LEDRed: communication error or address is 0Red flashing: peripheral fault LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDGreen: voltage OKFlashing green: address 0 or peripheral error LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 70 mA (without sensors) / max. 200 mA Protection classIII Current consumptionIAUX ≤ 650 mA Surge protectionUAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Input Number/Type2 analog inputsCurrent: 0 ... 20 mA/4 ... 20 mAvoltage: 0 ... 10 V SupplyFrom AS-Interface (switch setting INT, default setting) or from auxiliary voltage UAUX (switch setting AUX) Current loading capacity≤ 100 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA From auxiliary voltage UAUX (AUX switch position) , overload and short-circuit protected Input resistancecurrent input: max. 70 Ω voltage input: 100 kΩ Accuracy0.1 % of input signal range at 25 °C (298 K) Resolution15 Bit Temperature influence0.0025 %/K of input signal range Output Temperature influence1 µA/K or 0,3 mV/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID1 codeF ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Indication of the peripheral fault by exceeding measuring rangeP2=1, peripheral fault is reportedP2=0, peripheral fault is not reported P3P3=1, normal operating modeP3=0, both channels in current mode and without recognition of wire breakage Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 ConnectionRemovable push-in terminalsrated connection capacity:rigid: 0.20 mm2 ... 1.5 mm2flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass110 g MountingDIN mounting rail NoteMax. length of jumpers = 5 cm Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-2E-KE5-IJL/UJL Product Description Switch cabinet module2 analog Inputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.1 UL File NumberE223772 MTBF154 a Indicators/operating means LED FAULTFault indication: red LEDRed: communication error or address is 0Red flashing: peripheral fault LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDGreen: voltage OKFlashing green: address 0 or peripheral error LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INstatus of input signal; LED yellowoff: not activeon: signal within measurement rangeflashing: signal outside of measurement range Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 70 mA (without sensors) / max. 200 mA Protection classIII Current consumptionIAUX ≤ 650 mA Surge protectionUAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Input Number/Type2 analog inputsCurrent: 0 ... 20 mA/4 ... 20 mAvoltage: 0 ... 10 V SupplyFrom AS-Interface (switch setting INT, default setting) or from auxiliary voltage UAUX (switch setting AUX) Current loading capacity≤ 100 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA From auxiliary voltage UAUX (AUX switch position) , overload and short-circuit protected Input resistancecurrent input: max. 70 Ω voltage input: 100 kΩ Accuracy0.1 % of input signal range at 25 °C (298 K) Resolution15 Bit Temperature influence0.0025 %/K of input signal range Output Temperature influence1 µA/K or 0,3 mV/K Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.3.D IO code7 ID code3 ID1 codeF ID2 codeD Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3. Parameter bits (programmable via AS-i)function P050/60 Hz filterP0=1, enabledP0=0, disabled P1projecting of the 2nd channelP1=1, channel 2 is projectedP1=0, channel 2 is not projected P2Indication of the peripheral fault by exceeding measuring rangeP2=1, peripheral fault is reportedP2=0, peripheral fault is not reported P3P3=1, normal operating modeP3=0, both channels in current mode and without recognition of wire breakage Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree2 Mechanical specifications Degree of protectionIP20 ConnectionRemovable push-in terminalsrated connection capacity:rigid: 0.20 mm2 ... 1.5 mm2flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass110 g MountingDIN mounting rail NoteMax. length of jumpers = 5 cm Classifications SystemClasscode ECLASS 11.027242601 ECLASS 10.0.127242601 ECLASS 9.027242601 ECLASS 8.027242601 ECLASS 5.127242601 ETIM 8.0EC001596 ETIM 7.0EC001596 ETIM 6.0EC001596 ETIM 5.0EC001596 UNSPSC 12.139121535

Comentários sobre a nossa empresa