VBA-4E1A-KE3-ZEJ/SR PEPPERL+FUCHS - Part number: 203796
Não disponível em stock - Por encomenda
Para encomendar ao fabricante
749,85 USD

Impostos de importação excluídos

Tens de ter sessão iniciada

VBA-4E1A-KE3-ZEJ/SR PEPPERL+FUCHS - Part number: 203796

PEPPERL+FUCHS

AS-Interface safety module VBA-4E1A-KE3-ZEJ/SR VBA-4E1A-KE3-ZEJ/SR Safety output module with diagnostic node Safe relay output with galvanically isolated contact sets Assigns a complete address for the safe output and one A/B address for the inputs 4 inputs can be used either for diagnostics and EDM or as standard inputs Applications up to category 4/PL e/SIL 3 Several safe output modules can be grouped into one enabling circuit AS-Interface safety module VBA-4E1A-KE3-ZEJ/SR VBA-4E1A-KE3-ZEJ/SR Safety output module with diagnostic node Safe relay output with galvanically isolated contact sets Assigns a complete address for the safe output and one A/B address for the inputs 4 inputs can be used either for diagnostics and EDM or as standard inputs Applications up to category 4/PL e/SIL 3 Several safe output modules can be grouped into one enabling circuit

MPNs 203796, PEP203796, VBA-4E1A-KE3-ZEJ/SR
Código HS 85371091
Weight N/A

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

749,85 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

1 Disponível a partir de parceiros Preço e entrega sob consulta.
Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  VBA-4E1A-KE3-ZEJ/SR Product Description KE3 control cabinet module, 4 inputs, 1 control-safe relay output General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e Indicators/operating means LED FAULTerror display; LED redred: communication error LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow LED OUTFor flashing patterns see diagnostics table LED ALARMPLC reports alarm; red LED Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V DC Current loading capacity≤ 90 mA, overload- and short-circuit proof (INT) Input current≤ 8 mA (limited internally) Sensor supply≤ 90 mA Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type1 safety relay output Supplyfrom AS-Interface Nominal load Per contact3 A / 24 V DC; 3 A / 230 V AC Usage categoryDC-13 and AC-15 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-7.A.E IO code7 ID codeA ID1 code5 (Can be changed to 7 or F) ID2 codeE Data bits (function via AS-Interface)InputOutput D0 E0 LED ALARM Diagnosis (see table Device colors) D1 E1 OUT1 (see P1) D2 E2 - D3 E3 = 1.Y1 - Parameter bits (programmable via AS-i)function P0not used P1Output linkage:P1 = 1: safe output switches on release.P1 = 0: safe output switches on release and OUT1=1 P2ID1=5not usedID1=7 or FP2 = 0 IN3 is inputP2 = 1 IN3 notifies of release P3not used Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E1A-KE3-ZEJ/SR Product Description KE3 control cabinet module, 4 inputs, 1 control-safe relay output General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 Performance level (PL)PL e Indicators/operating means LED FAULTerror display; LED redred: communication error LED PWRAS-Interface voltage; LED green LED INswitching state (input); 4 LED yellow LED OUTFor flashing patterns see diagnostics table LED ALARMPLC reports alarm; red LED Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 30 mA (without sensors) / max. 200 mA Protection classIII Surge protectionUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V DC Current loading capacity≤ 90 mA, overload- and short-circuit proof (INT) Input current≤ 8 mA (limited internally) Sensor supply≤ 90 mA Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type1 safety relay output Supplyfrom AS-Interface Nominal load Per contact3 A / 24 V DC; 3 A / 230 V AC Usage categoryDC-13 and AC-15 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-7.A.E IO code7 ID codeA ID1 code5 (Can be changed to 7 or F) ID2 codeE Data bits (function via AS-Interface)InputOutput D0 E0 LED ALARM Diagnosis (see table Device colors) D1 E1 OUT1 (see P1) D2 E2 - D3 E3 = 1.Y1 - Parameter bits (programmable via AS-i)function P0not used P1Output linkage:P1 = 1: safe output switches on release.P1 = 0: safe output switches on release and OUT1=1 P2ID1=5not usedID1=7 or FP2 = 0 IN3 is inputP2 = 1 IN3 notifies of release P3not used Ambient conditions Ambient temperature0 ... 55 °C (32 ... 131 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Comentários sobre a nossa empresa