OCT300-M1K-N2 PEPPERL+FUCHS - Part number: 106541
Não disponível em stock - Por encomenda
Para encomendar ao fabricante
684,23 USD

Impostos de importação excluídos

Tens de ter sessão iniciada

OCT300-M1K-N2 PEPPERL+FUCHS - Part number: 106541

PEPPERL+FUCHS

Diffuse mode sensor, NAMUR OCT300-M1K-N2 OCT300-M1K-N2 ATEX-, IECEX approval for zone 20 (Dust) and zone 1 (Gas) Intrinsically safe, Ex op is ia IIC T6 Gb/IIIC T 135 °C Da Adjustable sensor head Scratch resistant mineral glass lens Diffuse mode sensor, NAMUR OCT300-M1K-N2 OCT300-M1K-N2 ATEX-, IECEX approval for zone 20 (Dust) and zone 1 (Gas) Intrinsically safe, Ex op is ia IIC T6 Gb/IIIC T 135 °C Da Adjustable sensor head Scratch resistant mineral glass lens

MPNs 106541, PEP106541, OCT300-M1K-N2
Código HS 85365000
Weight 0.1 kg

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

684,23 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  OCT300-M1K-N2 Product Description Diffuse mode sensor, NAMUR, special design, 300 mm detection range, infrared light, light/dark on, DC version, NAMUR output, terminal compartment General specifications Detection range0 ... 300 mm Adjustment range70 ... 300 mm Reference targetstandard white 200 mm x 200 mm Light sourceIRED , 880 nm Light typemodulated infrared light Ambient light limit≤ 40000 Lux sun light ≤ 30000 Lux halogen light Temperature influence≤ 0.5 mm/K Functional safety related parameters MTTFd1319 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Function indicatorLED yellow: switching state Control elementsSensing range adjuster Electrical specifications Operating voltage6 ... 20 V DC (Ri 0 Ohm) Ripple5 % Time delay before availability20 ms Output Switching typelight/dark on, programmable Signal output1 NAMUR output NC/NO programmable Switching voltage8 V DC (Ri 1 kΩ) Switching frequency≤ 100 Hz Current consumption Reference target detectedconnection 1, 2: ≤ 1 mA connection 3, 4: ≥ 2.7 mA Reference target not detectedconnection 1, 2: ≥ 2.7 mA connection 3, 4: ≤ 1 mA Response time5 ms Repeat accuracy≤ 0.5 % of the sensing range Conformity Product standardEN 60947-5-2 Compliance with standards and directives Standard conformity StandardsEN 60947-5-6:2000 Approvals and certificates FM approval Approved forIS / I,II,III / 1 / ABCDEFG / T5 - 116-0110; EntityNI / I / 2 / ABCD / T6Entity Parameters:VMax = 12.6 V, IMax = 20 mA, Ci = 1.11 µF, Li = 0 mH (Groups A, B, C, D, E, F, G).VMax = 15.5 V, IMax = 52 mA, Ci = 1.11 µF, Li = 0 mH (Groups C, D, E, F, G). CSA approval Approved forClass I, Division 2, Groups A, B, C and DRated 20V (max), 50mA.These sensors are suitable for installation in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit, as acceptable to the local inspection authority having jurisdiction. CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 80 °C (-40 ... 176 °F) Mechanical specifications Housing width30 mm Housing height30 mm Housing depth102 mm Degree of protectionIP67 ConnectionM16 terminal compartment, core cross section ≤ 2.5 mm2 Material HousingPBT Optical faceScratch resistant mineral glass lens Mass100 g ATEX G EC-Type Examination CertificatePTB 01 ATEX 2203 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. ATEX D EC-Type Examination CertificateZELM 03 ATEX 0196 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 20/21: II 1D Ex ia IIIC T 135°C Da Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the surface temperature class. In applications where high levels of charge are expected (e.g. electrostatic paint, foil manufacture, dust extraction, mechanical friction), structural measures must be taken to limit the surface area of the plastic housing exposed to this charge to approximately 15 cm2 in order to avoid propagating brush discharge. When setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. IECEx G Certificate numberIECEx PTB 12.0060 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. IECEx D Certificate numberIECEx ZLM 12.0005X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingEx ia IIIC T135°C Da StandardsIEC 60079-0:2011 IEC 60079-11:2011 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsWhen setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  OCT300-M1K-N2 Product Description Diffuse mode sensor, NAMUR, special design, 300 mm detection range, infrared light, light/dark on, DC version, NAMUR output, terminal compartment General specifications Detection range0 ... 300 mm Adjustment range70 ... 300 mm Reference targetstandard white 200 mm x 200 mm Light sourceIRED , 880 nm Light typemodulated infrared light Ambient light limit≤ 40000 Lux sun light ≤ 30000 Lux halogen light Temperature influence≤ 0.5 mm/K Functional safety related parameters MTTFd1319 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Function indicatorLED yellow: switching state Control elementsSensing range adjuster Electrical specifications Operating voltage6 ... 20 V DC (Ri 0 Ohm) Ripple5 % Time delay before availability20 ms Output Switching typelight/dark on, programmable Signal output1 NAMUR output NC/NO programmable Switching voltage8 V DC (Ri 1 kΩ) Switching frequency≤ 100 Hz Current consumption Reference target detectedconnection 1, 2: ≤ 1 mA connection 3, 4: ≥ 2.7 mA Reference target not detectedconnection 1, 2: ≥ 2.7 mA connection 3, 4: ≤ 1 mA Response time5 ms Repeat accuracy≤ 0.5 % of the sensing range Conformity Product standardEN 60947-5-2 Compliance with standards and directives Standard conformity StandardsEN 60947-5-6:2000 Approvals and certificates FM approval Approved forIS / I,II,III / 1 / ABCDEFG / T5 - 116-0110; EntityNI / I / 2 / ABCD / T6Entity Parameters:VMax = 12.6 V, IMax = 20 mA, Ci = 1.11 µF, Li = 0 mH (Groups A, B, C, D, E, F, G).VMax = 15.5 V, IMax = 52 mA, Ci = 1.11 µF, Li = 0 mH (Groups C, D, E, F, G). CSA approval Approved forClass I, Division 2, Groups A, B, C and DRated 20V (max), 50mA.These sensors are suitable for installation in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit, as acceptable to the local inspection authority having jurisdiction. CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 80 °C (-40 ... 176 °F) Mechanical specifications Housing width30 mm Housing height30 mm Housing depth102 mm Degree of protectionIP67 ConnectionM16 terminal compartment, core cross section ≤ 2.5 mm2 Material HousingPBT Optical faceScratch resistant mineral glass lens Mass100 g ATEX G EC-Type Examination CertificatePTB 01 ATEX 2203 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. ATEX D EC-Type Examination CertificateZELM 03 ATEX 0196 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 20/21: II 1D Ex ia IIIC T 135°C Da Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the surface temperature class. In applications where high levels of charge are expected (e.g. electrostatic paint, foil manufacture, dust extraction, mechanical friction), structural measures must be taken to limit the surface area of the plastic housing exposed to this charge to approximately 15 cm2 in order to avoid propagating brush discharge. When setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. IECEx G Certificate numberIECEx PTB 12.0060 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. IECEx D Certificate numberIECEx ZLM 12.0005X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingEx ia IIIC T135°C Da StandardsIEC 60079-0:2011 IEC 60079-11:2011 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsWhen setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. Classifications SystemClasscode ECLASS 11.027270903 ECLASS 10.0.127270903 ECLASS 9.027270903 ECLASS 8.027270903 ECLASS 5.127270903 ETIM 8.0EC001821 ETIM 7.0EC001821 ETIM 6.0EC001821 ETIM 5.0EC001821 UNSPSC 12.139121528

Comentários sobre a nossa empresa