RLK61-55-Z/31/135 PEPPERL+FUCHS - Part number: 911616
Disponíveis a pedido

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

RLK61-55-Z/31/135 PEPPERL+FUCHS - Part number: 911616

PEPPERL+FUCHS

Retroreflective sensor RLK61-55-Z/31/135 RLK61-55-Z/31/135 Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360° high visibility LEDs Programmable ON-delay, OFF-delay, and One-shot timers Version for universal voltages Relay output Retroreflective sensor RLK61-55-Z/31/135 RLK61-55-Z/31/135 Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360° high visibility LEDs Programmable ON-delay, OFF-delay, and One-shot timers Version for universal voltages Relay output

MPNs 911616, PEP911616, RLK61-55-Z/31/135
Código HS 85365090
Weight 0.14 kg

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Disponíveis a pedido

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Informações do produto

Descrição

Datasheet excerpt: Technical data of  RLK61-55-Z/31/135 Product Description Retroreflective sensor with polarization filter General specifications Effective detection range0 ... 18 m Reflector distance0.3 ... 18 m Threshold detection range25 m Reference targetFE-RR1 reflector Light sourceLED Light typemodulated visible red light , 630 nm Polarization filteryes Diameter of the light spot350 mm at a distance of 18 m Opening angle1.1 ° Optical facefrontal Ambient light limit5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator2 LEDs green Function indicator2 LEDs yellow lights up when receiving the light beam ; flashes when falling short of the stability control; OFF when light beam is interrupted Control elementsLight-on/dark-on changeover switch Control elementsSensing range adjuster Control elementsTime adjuster ( 0 ... 10 s ) Electrical specifications Operating voltage24 ... 240 V AC 12 ... 240 V DC No-load supply current≤ 35 mA Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption≤ 2 VA Output Switching typelight/dark on, switchable Signal output1 SPDT relay Switching voltagemax. 250 V AC/DC Switching currentmax. 3 A Switching powerDC: max. 150 W AC: max. 750 VA Switching frequency20 Hz Response time≤ 25 ms Timer functionDIP switch for selection of operating modes Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 Standard conformity Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007 StandardsEN 50178, UL 508 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 UL approvalcULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 55 °C (-40 ... 131 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width45 mm Housing height73.7 mm Housing depth48.6 mm Degree of protectionIP67 Connection5-pin V95 connector (7/8"-16 UN 2A) Material HousingPC (Polycarbonate) Optical facePMMA Mass140 g Tightening torque, fastening screwsmax. 2 Nm Classifications SystemClasscode ECLASS 11.027270902 ECLASS 10.0.127270902 ECLASS 9.027270902 ECLASS 8.027270902 ECLASS 5.127270902 ETIM 8.0EC002717 ETIM 7.0EC002717 ETIM 6.0EC002717 ETIM 5.0EC002717 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  RLK61-55-Z/31/135 Product Description Retroreflective sensor with polarization filter General specifications Effective detection range0 ... 18 m Reflector distance0.3 ... 18 m Threshold detection range25 m Reference targetFE-RR1 reflector Light sourceLED Light typemodulated visible red light , 630 nm Polarization filteryes Diameter of the light spot350 mm at a distance of 18 m Opening angle1.1 ° Optical facefrontal Ambient light limit5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator2 LEDs green Function indicator2 LEDs yellow lights up when receiving the light beam ; flashes when falling short of the stability control; OFF when light beam is interrupted Control elementsLight-on/dark-on changeover switch Control elementsSensing range adjuster Control elementsTime adjuster ( 0 ... 10 s ) Electrical specifications Operating voltage24 ... 240 V AC 12 ... 240 V DC No-load supply current≤ 35 mA Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption≤ 2 VA Output Switching typelight/dark on, switchable Signal output1 SPDT relay Switching voltagemax. 250 V AC/DC Switching currentmax. 3 A Switching powerDC: max. 150 W AC: max. 750 VA Switching frequency20 Hz Response time≤ 25 ms Timer functionDIP switch for selection of operating modes Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 Standard conformity Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007 StandardsEN 50178, UL 508 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 UL approvalcULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 55 °C (-40 ... 131 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width45 mm Housing height73.7 mm Housing depth48.6 mm Degree of protectionIP67 Connection5-pin V95 connector (7/8"-16 UN 2A) Material HousingPC (Polycarbonate) Optical facePMMA Mass140 g Tightening torque, fastening screwsmax. 2 Nm Classifications SystemClasscode ECLASS 11.027270902 ECLASS 10.0.127270902 ECLASS 9.027270902 ECLASS 8.027270902 ECLASS 5.127270902 ETIM 8.0EC002717 ETIM 7.0EC002717 ETIM 6.0EC002717 ETIM 5.0EC002717 UNSPSC 12.139121528

Comentários sobre a nossa empresa