LA61/LK61-Z/31/135 PEPPERL+FUCHS - Part number: 913909
Disponíveis a pedido

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

LA61/LK61-Z/31/135 PEPPERL+FUCHS - Part number: 913909

PEPPERL+FUCHS

Thru-beam sensor LA61/LK61-Z/31/135 LA61/LK61-Z/31/135 Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360° high visibility LEDs Programmable ON-delay, OFF-delay, and One-shot timers Version for universal voltages Relay output Thru-beam sensor LA61/LK61-Z/31/135 LA61/LK61-Z/31/135 Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360° high visibility LEDs Programmable ON-delay, OFF-delay, and One-shot timers Version for universal voltages Relay output

MPNs 913909, PEP913909, LA61/LK61-Z/31/135
Código HS 85365000
Weight 0.14 kg

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Disponíveis a pedido

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Informações do produto

Descrição

Datasheet excerpt: Technical data of  LA61/LK61-Z/31/135 Product Description Thru-beam sensor System components EmitterLA61/135 ReceiverLK61-Z/31/135 General specifications Effective detection range0 ... 60 m Threshold detection range85 m Light sourceIRED Light typemodulated infrared light , 850 nm Diameter of the light spot1600 mm at a distance of 60 m Opening angleEmitter: 1.5 ° , Receiver: 1.5 ° Optical facefrontal Ambient light limit5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator2 LEDs green Function indicator2 LEDs yellow Receiver: receiver LED yellow, lights up when light beam is free, flashes when falling short of the stability control ; OFF when light beam is interrupted Control elementsLight-on/dark-on changeover switch Control elementsSensing range adjuster Control elementsTime adjuster ( 0 ... 10 s ) Electrical specifications Operating voltage24 ... 240 V AC 12 ... 240 V DC No-load supply current≤ 35 mA Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption≤ 2 VA per device Output Switching typelight/dark on, switchable Signal output1 SPDT relay Switching voltagemax. 250 V AC/DC Switching currentmax. 3 A Switching powerDC: max. 150 W AC: max. 750 VA Switching frequency20 Hz Response time≤ 25 ms Timer functionDIP-switch for selection of operating modes Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 Standard conformity Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007 StandardsEN 50178, UL 508 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 UL approvalcULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 55 °C (-40 ... 131 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width45 mm Housing height73.7 mm Housing depth48.6 mm Degree of protectionIP67 Connection7/8"-16 UN connector Material HousingPC (glass-fiber-reinforced Makrolon) Optical facePMMA Mass140 g per device Tightening torque, fastening screws< 2 Nm Classifications SystemClasscode ECLASS 11.027270901 ECLASS 10.0.127270901 ECLASS 9.027270901 ECLASS 8.027270901 ECLASS 5.127270901 ETIM 8.0EC002716 ETIM 7.0EC002716 ETIM 6.0EC002716 ETIM 5.0EC002716 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  LA61/LK61-Z/31/135 Product Description Thru-beam sensor System components EmitterLA61/135 ReceiverLK61-Z/31/135 General specifications Effective detection range0 ... 60 m Threshold detection range85 m Light sourceIRED Light typemodulated infrared light , 850 nm Diameter of the light spot1600 mm at a distance of 60 m Opening angleEmitter: 1.5 ° , Receiver: 1.5 ° Optical facefrontal Ambient light limit5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator2 LEDs green Function indicator2 LEDs yellow Receiver: receiver LED yellow, lights up when light beam is free, flashes when falling short of the stability control ; OFF when light beam is interrupted Control elementsLight-on/dark-on changeover switch Control elementsSensing range adjuster Control elementsTime adjuster ( 0 ... 10 s ) Electrical specifications Operating voltage24 ... 240 V AC 12 ... 240 V DC No-load supply current≤ 35 mA Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption≤ 2 VA per device Output Switching typelight/dark on, switchable Signal output1 SPDT relay Switching voltagemax. 250 V AC/DC Switching currentmax. 3 A Switching powerDC: max. 150 W AC: max. 750 VA Switching frequency20 Hz Response time≤ 25 ms Timer functionDIP-switch for selection of operating modes Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 Standard conformity Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007 StandardsEN 50178, UL 508 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 UL approvalcULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 55 °C (-40 ... 131 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width45 mm Housing height73.7 mm Housing depth48.6 mm Degree of protectionIP67 Connection7/8"-16 UN connector Material HousingPC (glass-fiber-reinforced Makrolon) Optical facePMMA Mass140 g per device Tightening torque, fastening screws< 2 Nm Classifications SystemClasscode ECLASS 11.027270901 ECLASS 10.0.127270901 ECLASS 9.027270901 ECLASS 8.027270901 ECLASS 5.127270901 ETIM 8.0EC002716 ETIM 7.0EC002716 ETIM 6.0EC002716 ETIM 5.0EC002716 UNSPSC 12.139121528

Comentários sobre a nossa empresa