LS610-DA-IBS/F1/146 PEPPERL+FUCHS - Part number: 183170
Disponíveis a pedido

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

LS610-DA-IBS/F1/146 PEPPERL+FUCHS - Part number: 183170

PEPPERL+FUCHS

Optical data coupler LS610-DA-IBS/F1/146 LS610-DA-IBS/F1/146 Devices for INTERBUS Version for low temperature applications Plug connection for fast mounting No parameterization Usable up to detection range 0 Line indicator for signal strength Optical data coupler LS610-DA-IBS/F1/146 LS610-DA-IBS/F1/146 Devices for INTERBUS Version for low temperature applications Plug connection for fast mounting No parameterization Usable up to detection range 0 Line indicator for signal strength

MPNs 183170, PEP183170, LS610-DA-IBS/F1/146
Código HS 85365000
Weight 0.7 kg

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Disponíveis a pedido

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  LS610-DA-IBS/F1/146 Product Description Optical data coupler for INTERBUS, 120 m detection range, infrared light, M12 plug, low temperature version General specifications Effective detection range0 ... 120 m Threshold detection range140 m Light typemodulated infrared light Diameter of the light spot2 m at a distance of 100 m Opening angle1.1 ° Ambient light limit> 10000 Lux Functional safety related parameters MTTFd260 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Data flow indicatorLED green: emitterLED yellow: receiver Function indicatoralignment aid: flashing front red LED Signal strength (8 LED: Red, yellow, green) Electrical specifications Operating voltage18 ... 30 V DC No-load supply current200 mA Data rate0 ... 2 MBit/s Operation frequencyF1 = 8.25 MHz Interface Interface typeRS 422 , galvanically isolated Output Pre-fault indication output1 PNP (switches if there is sufficient stability control) short-circuit protected, max. 200 mA Conformity Product standardEN 60947-5-2 Approvals and certificates EAC conformityTR CU 020/2011 ApprovalsCE, cULus Ambient conditions Ambient temperature-30 ... 50 °C (-22 ... 122 °F) , For use in dry cold Storage temperature-30 ... 70 °C (-22 ... 158 °F) Mechanical specifications Degree of protectionIP65 Connection4-pin, M12x1 connector, standard (supply) ,5-pin, M12x1 connector, B-coded (Remote Bus In) ,5-pin, M12x1 socket, B-coded (Remote Bus Out) Material HousingABS / PC Optical faceplastic Mass700 g Classifications SystemClasscode ECLASS 11.027270901 ECLASS 10.0.127270901 ECLASS 9.027270901 ECLASS 8.027270901 ECLASS 5.127270901 ETIM 8.0EC002716 ETIM 7.0EC002716 ETIM 6.0EC002716 ETIM 5.0EC002716 UNSPSC 12.143201404 Datasheet excerpt: Technical data of  LS610-DA-IBS/F1/146 Product Description Optical data coupler for INTERBUS, 120 m detection range, infrared light, M12 plug, low temperature version General specifications Effective detection range0 ... 120 m Threshold detection range140 m Light typemodulated infrared light Diameter of the light spot2 m at a distance of 100 m Opening angle1.1 ° Ambient light limit> 10000 Lux Functional safety related parameters MTTFd260 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Data flow indicatorLED green: emitterLED yellow: receiver Function indicatoralignment aid: flashing front red LED Signal strength (8 LED: Red, yellow, green) Electrical specifications Operating voltage18 ... 30 V DC No-load supply current200 mA Data rate0 ... 2 MBit/s Operation frequencyF1 = 8.25 MHz Interface Interface typeRS 422 , galvanically isolated Output Pre-fault indication output1 PNP (switches if there is sufficient stability control) short-circuit protected, max. 200 mA Conformity Product standardEN 60947-5-2 Approvals and certificates EAC conformityTR CU 020/2011 ApprovalsCE, cULus Ambient conditions Ambient temperature-30 ... 50 °C (-22 ... 122 °F) , For use in dry cold Storage temperature-30 ... 70 °C (-22 ... 158 °F) Mechanical specifications Degree of protectionIP65 Connection4-pin, M12x1 connector, standard (supply) ,5-pin, M12x1 connector, B-coded (Remote Bus In) ,5-pin, M12x1 socket, B-coded (Remote Bus Out) Material HousingABS / PC Optical faceplastic Mass700 g Classifications SystemClasscode ECLASS 11.027270901 ECLASS 10.0.127270901 ECLASS 9.027270901 ECLASS 8.027270901 ECLASS 5.127270901 ETIM 8.0EC002716 ETIM 7.0EC002716 ETIM 6.0EC002716 ETIM 5.0EC002716 UNSPSC 12.143201404

Comentários sobre a nossa empresa