PMI80-F90-3EP-IO-V15 PEPPERL+FUCHS - Part number: 231921
Não disponível em stock - Por encomenda
Para encomendar ao fabricante
487,22 USD

Impostos de importação excluídos

Tens de ter sessão iniciada

PMI80-F90-3EP-IO-V15 PEPPERL+FUCHS - Part number: 231921

PEPPERL+FUCHS

Inductive positioning system PMI80-F90-3EP-IO-V15 PMI80-F90-3EP-IO-V15 Parameterization and diagnosis via IO-Link Measuring range 0 ... 80 mm Parameterisable measuring range 3 Push-pull outputs Switch points programmable via IO-Link Inductive positioning system PMI80-F90-3EP-IO-V15 PMI80-F90-3EP-IO-V15 Parameterization and diagnosis via IO-Link Measuring range 0 ... 80 mm Parameterisable measuring range 3 Push-pull outputs Switch points programmable via IO-Link

MPNs 231921, PEP231921, PMI80-F90-3EP-IO-V15
Código HS 85219000
Weight N/A

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

487,22 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  PMI80-F90-3EP-IO-V15 General specifications Switching element function3 switch outputs, programmable Object distance0.5 ... 3 mm , recommended: 1.5 mm Measurement range0 ... 80 mm Linearity range1 ... 79 mm Nominal ratings Operating voltage12 ... 30 V DC Reverse polarity protectionreverse polarity protected Linearity errorwithin measuring range: ± 0.8 mm within linearity range: ± 0.4 mm Repeat accuracy± 0.1 mm Resolution50 µm Temperature drift± 0.5 mm (-25 °C ... 70 °C) No-load supply current≤ 40 mA Operating voltage indicatorLED green Functional safety related parameters MTTFd311 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED S1switching state Switching output 1 LED S2switching state Switching output 2 LED S3switching state, Switching output 3 LED STATUSStatus display LED, green/red (Power on, communication/error, missing damping element) Interface Interface typeIO-Link (via C/Q = Pin 4) IO-Link revision1.1 Device profileSmart Sensor Device ID0x200302 (2097922) Transfer rateCOM2 (38.4 kBit/s) Value range0000h ... 6400h Min. cycle time2.3 ms Process data widthProcess data input: 16 Bit Process data output: none SIO mode supportyes Compatible master port typeA Switching output Output type3 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection , overvoltage protected Operating current≤ 100 mA / Output Switching window± 1 mm Switching hysteresis0.2 mm Voltage drop≤ 3 V Short-circuit protectionpulsing Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 EN 61131-9:2013 Approvals and certificates UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure Marine approvalDNVGL TAA00001V2 Ambient conditions Ambient temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Connection type5-pin, M12 x 1 connector Degree of protectionIP67 / IP69K Material HousingPBT, stainless steel 1.4571 , brass, nickel-plated Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) Mass83 g Classifications SystemClasscode ECLASS 11.027270702 ECLASS 10.0.127270702 ECLASS 9.027270702 ECLASS 8.027270702 ECLASS 5.127270702 ETIM 8.0EC001852 ETIM 7.0EC001852 ETIM 6.0EC001852 ETIM 5.0EC001852 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  PMI80-F90-3EP-IO-V15 General specifications Switching element function3 switch outputs, programmable Object distance0.5 ... 3 mm , recommended: 1.5 mm Measurement range0 ... 80 mm Linearity range1 ... 79 mm Nominal ratings Operating voltage12 ... 30 V DC Reverse polarity protectionreverse polarity protected Linearity errorwithin measuring range: ± 0.8 mm within linearity range: ± 0.4 mm Repeat accuracy± 0.1 mm Resolution50 µm Temperature drift± 0.5 mm (-25 °C ... 70 °C) No-load supply current≤ 40 mA Operating voltage indicatorLED green Functional safety related parameters MTTFd311 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED S1switching state Switching output 1 LED S2switching state Switching output 2 LED S3switching state, Switching output 3 LED STATUSStatus display LED, green/red (Power on, communication/error, missing damping element) Interface Interface typeIO-Link (via C/Q = Pin 4) IO-Link revision1.1 Device profileSmart Sensor Device ID0x200302 (2097922) Transfer rateCOM2 (38.4 kBit/s) Value range0000h ... 6400h Min. cycle time2.3 ms Process data widthProcess data input: 16 Bit Process data output: none SIO mode supportyes Compatible master port typeA Switching output Output type3 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection , overvoltage protected Operating current≤ 100 mA / Output Switching window± 1 mm Switching hysteresis0.2 mm Voltage drop≤ 3 V Short-circuit protectionpulsing Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 EN 61131-9:2013 Approvals and certificates UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure Marine approvalDNVGL TAA00001V2 Ambient conditions Ambient temperature-25 ... 85 °C (-13 ... 185 °F) Mechanical specifications Connection type5-pin, M12 x 1 connector Degree of protectionIP67 / IP69K Material HousingPBT, stainless steel 1.4571 , brass, nickel-plated Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) Mass83 g Classifications SystemClasscode ECLASS 11.027270702 ECLASS 10.0.127270702 ECLASS 9.027270702 ECLASS 8.027270702 ECLASS 5.127270702 ETIM 8.0EC001852 ETIM 7.0EC001852 ETIM 6.0EC001852 ETIM 5.0EC001852 UNSPSC 12.139121550