SJ3,5-N-K37 PEPPERL+FUCHS - Part number: 70132990
Disponíveis a pedido

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

SJ3,5-N-K37 PEPPERL+FUCHS - Part number: 70132990

PEPPERL+FUCHS

Inductive slot sensor SJ3,5-N-K37 SJ3,5-N-K37 Comfort series NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive slot sensor SJ3,5-N-K37 SJ3,5-N-K37 Comfort series NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

MPNs 70132990, PEP70132990, SJ3,5-N-K37
Código HS 85365090
Weight N/A

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Disponíveis a pedido

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Informações do produto

Descrição

Datasheet excerpt: Technical data of  SJ3,5-N-K37 General specifications Switching functionNormally closed (NC) Output typeNAMUR Slot width3.5 mm Depth of immersion (lateral)5 ... 7 typ. 6 mm Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 3000 Hz Hysteresis0.41 ... 0.6 mm Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Functional safety related parameters MTTFd5270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GbIECEx PTB 11.0091X Equipment protection level DaIECEx PTB 11.0091X Equipment protection level MbIECEx PTB 11.0091X ATEX approval Equipment protection level GbPTB 99 ATEX 2219 X Equipment protection level DaPTB 99 ATEX 2219 X UL approvalcULus Listed, General Purpose Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typeflexible leads LiY Housing materialPBT Degree of protectionIP67 Cable Cable diameter1.1 mm ± 0.1 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length500 mm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 Datasheet excerpt: Technical data of  SJ3,5-N-K37 General specifications Switching functionNormally closed (NC) Output typeNAMUR Slot width3.5 mm Depth of immersion (lateral)5 ... 7 typ. 6 mm Output type2-wire Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Operating voltage5 ... 25 V Switching frequency0 ... 3000 Hz Hysteresis0.41 ... 0.6 mm Current consumption Measuring plate not detected≥ 3 mA at nominal voltage Measuring plate detected≤ 1 mA at nominal voltage Functional safety related parameters MTTFd5270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GbIECEx PTB 11.0091X Equipment protection level DaIECEx PTB 11.0091X Equipment protection level MbIECEx PTB 11.0091X ATEX approval Equipment protection level GbPTB 99 ATEX 2219 X Equipment protection level DaPTB 99 ATEX 2219 X UL approvalcULus Listed, General Purpose Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Mechanical specifications Connection typeflexible leads LiY Housing materialPBT Degree of protectionIP67 Cable Cable diameter1.1 mm ± 0.1 mm Bending radius> 10 x cable diameter MaterialPVC Core cross section0.14 mm2 Length500 mm General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714