UC500-18GS-IUEP-IO-V15 PEPPERL+FUCHS - Part number: 304928-100001
Não disponível em stock - Por encomenda
Para encomendar ao fabricante
354,56 USD

Impostos de importação excluídos

Tens de ter sessão iniciada

UC500-18GS-IUEP-IO-V15 PEPPERL+FUCHS - Part number: 304928-100001

PEPPERL+FUCHS

Ultrasonic sensor UC500-18GS-IUEP-IO-V15 UC500-18GS-IUEP-IO-V15 IO-Link Interface for process data, parameterization and diagnosis Programmable via DTM with PACTWARE Programmable via IrDA (infrared interface) Selectable sound lobe width Synchronization options Enhanced temperature compensation adjustable, stable measuring values already 2 min after switching on Push-pull output Analog output Ultrasonic sensor UC500-18GS-IUEP-IO-V15 UC500-18GS-IUEP-IO-V15 IO-Link Interface for process data, parameterization and diagnosis Programmable via DTM with PACTWARE Programmable via IrDA (infrared interface) Selectable sound lobe width Synchronization options Enhanced temperature compensation adjustable, stable measuring values already 2 min after switching on Push-pull output Analog output

MPNs 304928-100001, PEP304928-100001, UC500-18GS-IUEP-IO-V15
Código HS 90318000
Weight N/A

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

354,56 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  UC500-18GS-IUEP-IO-V15 Product Description Single head system General specifications Sensing range30 ... 500 mm Adjustment range50 ... 500 mm Dead band0 ... 30 mm Standard target plate100 mm x 100 mm Transducer frequency300 kHz Response delayminimum : 20 ms factory setting: 40 ms Sensor cycle time≥ 10 ms (factory setting) ; programmable to 60 s Temperature influencewith temperature compensation: ≤ ± 0.75% of the end value 10 min after switching on the sensor (factory setting) with enhanced temperature compensation: ≤ ± 0.75% of the end value 2 min after switching on the sensor without temperature compensation: 0.17 %/K Memory Non-volatile memoryEEPROM Write cycles300000 Indicators/operating means LED greensolid: power onflashing: standby mode or IO-Link communication LED yellowsolid: object in evaluation rangeflashing: switch point programming, object detected LED redsolid: errorflashing: switch point programming, object not detected Electrical specifications Operating voltage10 ... 30 V DC , ripple 10 %SS No-load supply current≤ 60 mA Power consumption≤ 1000 mW Time delay before availability≤ 300 ms Interface 1 Interface typeIO-Link (via C/Q = Pin 4) IO-Link revision1.1 Device profileSmart Sensor Profile 2 Process data width32 bit Device ID0x300602 (3147266) Transfer rateCOM2 (38.4 kBit/s) Min. cycle time3 ms SIO mode supportyes Compatible master port typeClass A Class B (use 3-pole adapter or 3-wire cable) Interface 2 Interface typeIrDA (Infrared-Interface) Modepoint-to-point connection Transfer rate115.2 kBit/s Maximum communication distance5 cm Input/Output Input/output type1 synchronization connection, bidirectional 0 Level0 ... 1 V 1 Level2.5 V ... UB Input impedance> 22 kΩ Output rated operating currentcurrent source < 2.5 mA Pulse length≥ 1 ms with external control, low active Synchronization frequency Common mode operation≤ 100 Hz Multiplex operation≤ 71 Hz / n , n = number of sensors , n ≤ 10 Switching output Output type1 push-pull output , short-circuit protected , reverse polarity protected Rated operating current100 mA , short-circuit/overload protected Switching frequencyfactory setting: 14 Hz programmable to 33 Hz Voltage drop≤ 2.5 V Repeat accuracy≤ ± 0.1 % of full-scale value Range hysteresis1 % of the adjusted operating range (default settings), programmable , min. 1 mm Off-state current≤ 100 µA Analog output Output type1 analog output 0 (4) ... 20 mA or 1 analog output 0 ... 10 V Resolutioncurrent output: evaluation range [mm]/3200 but ≥ 0.35 mmvoltage output: evaluation range [mm]/4000 but ≥ 0.35 mm Deviation of the characteristic curve≤ ± 1 % of full-scale value Repeat accuracy≤ ± 0.1 % of full-scale value Load resistorcurrent output: ≤ 500 Ω voltage output: ≥ 1000 Ω Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003 IEC 61131-9:2013 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 037/2016 UL approvalcULus Listed, Class 2 Power Source CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Connection typeConnector plug M12 x 1 , 5-pin Degree of protectionIP67 Material Housingstainless steel (1.4305 / AISI 303)>BR>PA, PC, POM and PBT plastic parts Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam Installation positionany position Mass45 g Tightening torque, fastening screwsmax. 30 Nm Factory settings Output 1near switch point: 50 mm far switch point: 500 mm Output mode: Window mode output behavior: NO contact Output 2near limit: 50 mm far limit: 500 mm Output mode: rising ramp output behavior: Current output 4 mA ... 20 mA Beam widthwide Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960 Datasheet excerpt: Technical data of  UC500-18GS-IUEP-IO-V15 Product Description Single head system General specifications Sensing range30 ... 500 mm Adjustment range50 ... 500 mm Dead band0 ... 30 mm Standard target plate100 mm x 100 mm Transducer frequency300 kHz Response delayminimum : 20 ms factory setting: 40 ms Sensor cycle time≥ 10 ms (factory setting) ; programmable to 60 s Temperature influencewith temperature compensation: ≤ ± 0.75% of the end value 10 min after switching on the sensor (factory setting) with enhanced temperature compensation: ≤ ± 0.75% of the end value 2 min after switching on the sensor without temperature compensation: 0.17 %/K Memory Non-volatile memoryEEPROM Write cycles300000 Indicators/operating means LED greensolid: power onflashing: standby mode or IO-Link communication LED yellowsolid: object in evaluation rangeflashing: switch point programming, object detected LED redsolid: errorflashing: switch point programming, object not detected Electrical specifications Operating voltage10 ... 30 V DC , ripple 10 %SS No-load supply current≤ 60 mA Power consumption≤ 1000 mW Time delay before availability≤ 300 ms Interface 1 Interface typeIO-Link (via C/Q = Pin 4) IO-Link revision1.1 Device profileSmart Sensor Profile 2 Process data width32 bit Device ID0x300602 (3147266) Transfer rateCOM2 (38.4 kBit/s) Min. cycle time3 ms SIO mode supportyes Compatible master port typeClass A Class B (use 3-pole adapter or 3-wire cable) Interface 2 Interface typeIrDA (Infrared-Interface) Modepoint-to-point connection Transfer rate115.2 kBit/s Maximum communication distance5 cm Input/Output Input/output type1 synchronization connection, bidirectional 0 Level0 ... 1 V 1 Level2.5 V ... UB Input impedance> 22 kΩ Output rated operating currentcurrent source < 2.5 mA Pulse length≥ 1 ms with external control, low active Synchronization frequency Common mode operation≤ 100 Hz Multiplex operation≤ 71 Hz / n , n = number of sensors , n ≤ 10 Switching output Output type1 push-pull output , short-circuit protected , reverse polarity protected Rated operating current100 mA , short-circuit/overload protected Switching frequencyfactory setting: 14 Hz programmable to 33 Hz Voltage drop≤ 2.5 V Repeat accuracy≤ ± 0.1 % of full-scale value Range hysteresis1 % of the adjusted operating range (default settings), programmable , min. 1 mm Off-state current≤ 100 µA Analog output Output type1 analog output 0 (4) ... 20 mA or 1 analog output 0 ... 10 V Resolutioncurrent output: evaluation range [mm]/3200 but ≥ 0.35 mmvoltage output: evaluation range [mm]/4000 but ≥ 0.35 mm Deviation of the characteristic curve≤ ± 1 % of full-scale value Repeat accuracy≤ ± 0.1 % of full-scale value Load resistorcurrent output: ≤ 500 Ω voltage output: ≥ 1000 Ω Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003 IEC 61131-9:2013 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 037/2016 UL approvalcULus Listed, Class 2 Power Source CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Connection typeConnector plug M12 x 1 , 5-pin Degree of protectionIP67 Material Housingstainless steel (1.4305 / AISI 303)>BR>PA, PC, POM and PBT plastic parts Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam Installation positionany position Mass45 g Tightening torque, fastening screwsmax. 30 Nm Factory settings Output 1near switch point: 50 mm far switch point: 500 mm Output mode: Window mode output behavior: NO contact Output 2near limit: 50 mm far limit: 500 mm Output mode: rising ramp output behavior: Current output 4 mA ... 20 mA Beam widthwide Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960

Comentários sobre a nossa empresa