PEPPERL+FUCHS

Ultrasonic sensor UC500-D1-3K-V7 UC500-D1-3K-V7 Specially for level monitoring in vessels Large operating voltage range10 V DC ... 253 V DC20 V AC ... 253 V AC 3 relay outputs Parameter assignment via DIP-switches Temperature compensation Cable socket included with delivery Ultrasonic sensor UC500-D1-3K-V7 UC500-D1-3K-V7 Specially for level monitoring in vessels Large operating voltage range10 V DC ... 253 V DC20 V AC ... 253 V AC 3 relay outputs Parameter assignment via DIP-switches Temperature compensation Cable socket included with delivery

MPNs 212371, PEP212371, UC500-D1-3K-V7
Código HS 90318000
Weight 0.7 kg

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

771,02 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  UC500-D1-3K-V7 Product Description Single head system General specifications Sensing range60 ... 550 mm Dead band0 ... 60 mm Standard target plate100 mm x 100 mm Transducer frequency380 kHz Response delay> 10 s, relay< 1 s, LEDs Indicators/operating means LED redLED 1: overfill indicationLED 4: underfill indication LED green/yellowLED 2: overfill warning and normal operation LED 3: normal operation and underfill warning DIP switchsetting of the switch points/operating modes Electrical specifications Operating voltage10 ... 253 V DC 20 ... 253 V AC , 47 ... 63 Hz No-load supply current< 30 mA with UB = 30 V DC< 110 mA at UB = 10 V DC< 25 mA at UB = 220 V AC Output Output type3 relay outputs, normally open/closed, selectable Range hysteresis20 mm Contact loading253 V AC/150V DC, 3 A (ohm. load) Life spanelectrical: 105 switching cycles with ohmic load(3 A/253 V AC or 3 A/30 V DC)minimum contact load: 100 µA/100 mV DCmechanical: 20 x 106 switching cycles Temperature influence< 4 % Fusing≤ 3 A Slow-blow fuse per output in accordance with IEC 60127-2 Sheet 5 required. Recommendation: after a short circuit, check that the device is functioning correctly. Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 Approvals and certificates EAC conformityTR CU 004/2011 TR CU 020/2011 TR CU 037/2016 CCC approvalself-declaration Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Degree of protectionIP65 ConnectionFemale connector, V7 (7-pin), 90° Wire cross section: ≤1.5 mm2 cable diameter ∅7 ... 9 mm Material Housingcover: PC housing: PBTthreaded flange: stainless steel installation connector/cable socket: PETP Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam Mass700 g NoteIn case of loss or damage, the cable socket must be replaced by an identical cable socket (type V7-W) from Pepperl+Fuchs! Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960 Datasheet excerpt: Technical data of  UC500-D1-3K-V7 Product Description Single head system General specifications Sensing range60 ... 550 mm Dead band0 ... 60 mm Standard target plate100 mm x 100 mm Transducer frequency380 kHz Response delay> 10 s, relay< 1 s, LEDs Indicators/operating means LED redLED 1: overfill indicationLED 4: underfill indication LED green/yellowLED 2: overfill warning and normal operation LED 3: normal operation and underfill warning DIP switchsetting of the switch points/operating modes Electrical specifications Operating voltage10 ... 253 V DC 20 ... 253 V AC , 47 ... 63 Hz No-load supply current< 30 mA with UB = 30 V DC< 110 mA at UB = 10 V DC< 25 mA at UB = 220 V AC Output Output type3 relay outputs, normally open/closed, selectable Range hysteresis20 mm Contact loading253 V AC/150V DC, 3 A (ohm. load) Life spanelectrical: 105 switching cycles with ohmic load(3 A/253 V AC or 3 A/30 V DC)minimum contact load: 100 µA/100 mV DCmechanical: 20 x 106 switching cycles Temperature influence< 4 % Fusing≤ 3 A Slow-blow fuse per output in accordance with IEC 60127-2 Sheet 5 required. Recommendation: after a short circuit, check that the device is functioning correctly. Compliance with standards and directives Standard conformity StandardsEN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 Approvals and certificates EAC conformityTR CU 004/2011 TR CU 020/2011 TR CU 037/2016 CCC approvalself-declaration Ambient conditions Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Degree of protectionIP65 ConnectionFemale connector, V7 (7-pin), 90° Wire cross section: ≤1.5 mm2 cable diameter ∅7 ... 9 mm Material Housingcover: PC housing: PBTthreaded flange: stainless steel installation connector/cable socket: PETP Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam Mass700 g NoteIn case of loss or damage, the cable socket must be replaced by an identical cable socket (type V7-W) from Pepperl+Fuchs! Classifications SystemClasscode ECLASS 11.027272803 ECLASS 10.0.127272803 ECLASS 9.027272803 ECLASS 8.027272803 ECLASS 5.127272803 ETIM 8.0EC001849 ETIM 7.0EC001849 ETIM 6.0EC001849 ETIM 5.0EC001849 UNSPSC 12.141111960