IPH-30GM-Ex PEPPERL+FUCHS - Part number: 312969
Não disponível em stock - Por encomenda
Para encomendar ao fabricante
2 484,10 USD

Impostos de importação excluídos

Tens de ter sessão iniciada

IPH-30GM-Ex PEPPERL+FUCHS - Part number: 312969

PEPPERL+FUCHS

Read/write head hazardous area IPH-30GM-Ex IPH-30GM-Ex Read/write head with thread M30 x 1.5 ATEX-approval for zone 1 and zone 21 Degree of protection IP68 15 m connection cable For connection to IDENTControl control interface Encapsulation Ex m Read/write head hazardous area IPH-30GM-Ex IPH-30GM-Ex Read/write head with thread M30 x 1.5 ATEX-approval for zone 1 and zone 21 Degree of protection IP68 15 m connection cable For connection to IDENTControl control interface Encapsulation Ex m

MPNs 312969, PEP312969, IPH-30GM-Ex
Código HS 85176200
Weight 2 kg

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

2 484,10 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  IPH-30GM-Ex Product Description LF read/write head, for IDENTControl, for hazardous areas General specifications Operating frequency125 kHz Transfer rate2 kBit/s Operating distancemaximum: 10 mm Functional safety related parameters MTTFd700 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Electrical specifications Power consumption≤ 1.2 W Supplyfrom the IDENTControl Directive conformity Radio equipment Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364 RoHS Directive 2011/65/EU (RoHS)IEC/EN 63000 Standard conformity Explosion protectionEN IEC 60079-0EN 60079-18/A1 Degree of protectionEN 60529 RFIDISO/IEC 18000-2 Approvals and certificates ATEX approval Marking II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T130°C Db Equipment protection level GbIBExU 21ATEX1039 X Equipment protection level DbIBExU 21ATEX1039 X Ambient conditions Ambient temperature-20 ... 70 °C (-4 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Housing length105 mm ± 1 mm Housing diameter38 mm Degree of protectionIP68 Connection15 m connecting cable included with delivery Connection e.g. with terminal boxes Series GL5 Material HousingStainless steel 1.4305 / AISI 303 Installationflush Distance between two headsMultiplex on: ≥ 155 mm Multiplex off: ≥ 350 mm Mass2000 g General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027280401 ECLASS 10.0.127280401 ECLASS 9.027280401 ECLASS 8.027280401 ECLASS 5.127280401 ETIM 8.0EC002998 ETIM 7.0EC002998 ETIM 6.0EC002998 ETIM 5.0EC002998 Datasheet excerpt: Technical data of  IPH-30GM-Ex Product Description LF read/write head, for IDENTControl, for hazardous areas General specifications Operating frequency125 kHz Transfer rate2 kBit/s Operating distancemaximum: 10 mm Functional safety related parameters MTTFd700 a Mission Time (TM)10 a Diagnostic Coverage (DC)0 % Electrical specifications Power consumption≤ 1.2 W Supplyfrom the IDENTControl Directive conformity Radio equipment Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364 RoHS Directive 2011/65/EU (RoHS)IEC/EN 63000 Standard conformity Explosion protectionEN IEC 60079-0EN 60079-18/A1 Degree of protectionEN 60529 RFIDISO/IEC 18000-2 Approvals and certificates ATEX approval Marking II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T130°C Db Equipment protection level GbIBExU 21ATEX1039 X Equipment protection level DbIBExU 21ATEX1039 X Ambient conditions Ambient temperature-20 ... 70 °C (-4 ... 158 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Mechanical specifications Housing length105 mm ± 1 mm Housing diameter38 mm Degree of protectionIP68 Connection15 m connecting cable included with delivery Connection e.g. with terminal boxes Series GL5 Material HousingStainless steel 1.4305 / AISI 303 Installationflush Distance between two headsMultiplex on: ≥ 155 mm Multiplex off: ≥ 350 mm Mass2000 g General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027280401 ECLASS 10.0.127280401 ECLASS 9.027280401 ECLASS 8.027280401 ECLASS 5.127280401 ETIM 8.0EC002998 ETIM 7.0EC002998 ETIM 6.0EC002998 ETIM 5.0EC002998

Comentários sobre a nossa empresa