OPC120W-F200-R2-Ex PEPPERL+FUCHS - Part number: 70114069
Não disponível em stock - Por encomenda
Para encomendar ao fabricante
4 902,99 USD

Impostos de importação excluídos

Tens de ter sessão iniciada

OPC120W-F200-R2-Ex PEPPERL+FUCHS - Part number: 70114069

PEPPERL+FUCHS

Stationary read device OPC120W-F200-R2-Ex OPC120W-F200-R2-Ex Explosion protection for use in Zone 1, Zone 2, Zone 21 and Zone 22 Reads 1-D and 2-D codes at high speeds of up to 6 m/s at 30 readings/s High depth of focus Code quality index output Logo comparison Presence detection Stationary read device OPC120W-F200-R2-Ex OPC120W-F200-R2-Ex Explosion protection for use in Zone 1, Zone 2, Zone 21 and Zone 22 Reads 1-D and 2-D codes at high speeds of up to 6 m/s at 30 readings/s High depth of focus Code quality index output Logo comparison Presence detection

MPNs 70114069, PEP70114069, OPC120W-F200-R2-Ex
Código HS 84718000
Weight 7 kg

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

4 902,99 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  OPC120W-F200-R2-Ex Product Description Stationary read device for hazardous area General specifications Light typeIntegrated LED lightning (white) SymbologiesData Matrix, Code 39, Code 128, Int 2 of 5, EAN13, Pharmacode Read distance60 ... 160 mm Nominal distance: 120 mm Reading fieldMinimum read field: 28 mm x 45 mmRead field at nominal distance: 44 mm x 70 mmMaximum read field: 60 mm x 95 mm Modul sizeMinimum module size: 0.3 mm Evaluation frequencyup to 30 Hz Target velocitytriggered max. 6 m/s Data Matrix Symbol sizerectangular up to 144 x 144 modules rectangular up to 16 x 48 modules Data formatASCII, C40, Text, X12, Edifact, Base 256 , all according to ISO 646 Orientationomnidirectional Nominal ratings Camera TypeCMOS , Global shutter Number of pixels752 x 480 pixels Gray scale256 Image recordingreal-time , Program-controlled or triggered externally Functional safety related parameters MTTFd40.5 a Mission Time (TM)8 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green: Ready for operation LED indicationfor good/poor reading Electrical specifications Operating voltage24 V DC ± 15% , PELV No-load supply currentmax. 250 mA Power consumption6 W Interface Interface typeserial , RS 232 Transfer ratemax. 115.2 kBit/s Cable lengthmax. 30 m Interface 1 Interface typeEthernet ProtocolTCP/IP Transfer rate100 MBit/s Cable lengthmax. 30 m Input Input voltageto be applied externally 24 V ± 15% PELV Number/TypeTrigger Input current10 mA at 24 V DC Switching thresholdlow: < 10 V, high: > 15 V Cable lengthmax. 30 m Output Number/TypeGOOD, BAD, Matchcode Switching typePNP Switching voltageto be applied externally 24 V ± 15 % PELV Switching current100 mA each output Cable lengthmax. 30 m Compliance with standards and directives Standard conformity Noise immunityEN 61326-1 Emitted interferenceEN 61000-6-4 Degree of protectionEN 60529 Laser classIEC 60825-1:2007 Approvals and certificates IECEx approvalIECEx INE 14.0042X ATEX approvalINERIS 14 ATEX 0035X Device type: GUBW1.D.OS-OPC120W-F200-R2 Marking II 2 GDEx db IIC T6 GbEx tb IIIC T85°C Db Ambient conditions Ambient temperature0 ... 37 °C (32 ... 98.6 °F) Mechanical specifications Connection typeConnection terminals, max. conductor cross-section 2.5 mm2 Conductor cross section0.13 ... 2.5 mm2 Cable gland3 ... 8.5 mm Enclosure coverthreaded round cover Cover fixingflamepath thread Cover sealnone, O-ring for IP66/67 Flamepath greasepetroleum jelly Degree of protectionIP66 (IP66/67 with O-ring) Material Enclosurealuminum alloy Glassthermo-resistant tempered glass Finishepoxy coated RAL 7005 (grey) Mass7 kg GroundingM6 external grounding points Classifications SystemClasscode ECLASS 11.027280103 ECLASS 10.0.127280103 ECLASS 9.027280103 ECLASS 8.027280103 ECLASS 5.127280103 ETIM 8.0EC002999 ETIM 7.0EC002999 ETIM 6.0EC002999 ETIM 5.0EC002999 UNSPSC 12.143211701 Datasheet excerpt: Technical data of  OPC120W-F200-R2-Ex Product Description Stationary read device for hazardous area General specifications Light typeIntegrated LED lightning (white) SymbologiesData Matrix, Code 39, Code 128, Int 2 of 5, EAN13, Pharmacode Read distance60 ... 160 mm Nominal distance: 120 mm Reading fieldMinimum read field: 28 mm x 45 mmRead field at nominal distance: 44 mm x 70 mmMaximum read field: 60 mm x 95 mm Modul sizeMinimum module size: 0.3 mm Evaluation frequencyup to 30 Hz Target velocitytriggered max. 6 m/s Data Matrix Symbol sizerectangular up to 144 x 144 modules rectangular up to 16 x 48 modules Data formatASCII, C40, Text, X12, Edifact, Base 256 , all according to ISO 646 Orientationomnidirectional Nominal ratings Camera TypeCMOS , Global shutter Number of pixels752 x 480 pixels Gray scale256 Image recordingreal-time , Program-controlled or triggered externally Functional safety related parameters MTTFd40.5 a Mission Time (TM)8 a Diagnostic Coverage (DC)0 % Indicators/operating means Operation indicatorLED green: Ready for operation LED indicationfor good/poor reading Electrical specifications Operating voltage24 V DC ± 15% , PELV No-load supply currentmax. 250 mA Power consumption6 W Interface Interface typeserial , RS 232 Transfer ratemax. 115.2 kBit/s Cable lengthmax. 30 m Interface 1 Interface typeEthernet ProtocolTCP/IP Transfer rate100 MBit/s Cable lengthmax. 30 m Input Input voltageto be applied externally 24 V ± 15% PELV Number/TypeTrigger Input current10 mA at 24 V DC Switching thresholdlow: < 10 V, high: > 15 V Cable lengthmax. 30 m Output Number/TypeGOOD, BAD, Matchcode Switching typePNP Switching voltageto be applied externally 24 V ± 15 % PELV Switching current100 mA each output Cable lengthmax. 30 m Compliance with standards and directives Standard conformity Noise immunityEN 61326-1 Emitted interferenceEN 61000-6-4 Degree of protectionEN 60529 Laser classIEC 60825-1:2007 Approvals and certificates IECEx approvalIECEx INE 14.0042X ATEX approvalINERIS 14 ATEX 0035X Device type: GUBW1.D.OS-OPC120W-F200-R2 Marking II 2 GDEx db IIC T6 GbEx tb IIIC T85°C Db Ambient conditions Ambient temperature0 ... 37 °C (32 ... 98.6 °F) Mechanical specifications Connection typeConnection terminals, max. conductor cross-section 2.5 mm2 Conductor cross section0.13 ... 2.5 mm2 Cable gland3 ... 8.5 mm Enclosure coverthreaded round cover Cover fixingflamepath thread Cover sealnone, O-ring for IP66/67 Flamepath greasepetroleum jelly Degree of protectionIP66 (IP66/67 with O-ring) Material Enclosurealuminum alloy Glassthermo-resistant tempered glass Finishepoxy coated RAL 7005 (grey) Mass7 kg GroundingM6 external grounding points Classifications SystemClasscode ECLASS 11.027280103 ECLASS 10.0.127280103 ECLASS 9.027280103 ECLASS 8.027280103 ECLASS 5.127280103 ETIM 8.0EC002999 ETIM 7.0EC002999 ETIM 6.0EC002999 ETIM 5.0EC002999 UNSPSC 12.143211701

Comentários sobre a nossa empresa