KFU8-DW-1.D PEPPERL+FUCHS - Part number: 190149
Não disponível em stock - Por encomenda
Para encomendar ao fabricante
619,71 USD

Impostos de importação excluídos

Tens de ter sessão iniciada

KFU8-DW-1.D PEPPERL+FUCHS - Part number: 190149

PEPPERL+FUCHS

Rotation Speed Monitor KFU8-DW-1.D KFU8-DW-1.D Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec. Rotation Speed Monitor KFU8-DW-1.D KFU8-DW-1.D Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec.

MPNs 190149, PEP190149, KFU8-DW-1.D
Weight N/A

A imagem do produto é apenas para fins ilustrativos.
O país de origem, código HS e descrição são fornecidos pelo fabricante e podem estar sujeitos a alterações sem aviso prévio. Por esta razão, a PLC-City não pode ser responsabilizada por quaisquer discrepâncias.
Vendido pela PLC-CITY® e enviado da Itália

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

619,71 USD

Impostos de importação excluídos

Tens de ter sessão iniciada
Vendido pela PLC-CITY® e enviado da Itália
Somos um Parceiro Especialista de PEPPERL+FUCHS
Envio expresso grátis para Estados Unidos
Loader...
Ver todos os serviços de transporte
Solicite uma cotação para saber a data de entrega

Aceitamos muitos métodos de pagamento: Transferência Bancária (SEPA, ACH), Cartões de Débito/Crédito (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay, Przelewy24, WeChatPay.
Mais informações sobre os nossos métodos de pagamento

Este produto é coberto por uma garantia de 12 Meses, válida para defeitos de fabricação ou avarias. A garantia não cobre danos causados por uso indevido ou danos acidentais.
Saiba mais sobre nossa garantia

As devoluções requerem autorização prévia e resultam em crédito na loja. Itens sob encomenda (backorder) estão excluídos.

Ver a nossa política de devolução

Obtenha sua cotação personalizada agora

Um representante de vendas dedicado irá ajudá-lo a oferecer o melhor preço e prazos de entrega.

Tens de ter sessão iniciada

Solicite o seu serviço técnico personalizado

Confie na nossa equipa técnica especializada para uma gama de serviços personalizados: reparação, programação, manutenção e muito mais.

Informações do produto

Descrição

Datasheet excerpt: Technical data of  KFU8-DW-1.D Product Description Rotation Speed Monitor Functional safety related parameters MTTFd100 a Supply Rated voltage200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 20 VDC ... 30 VDC Fusingexternal fusing 4 A Power consumptionAC: < 5 VADC: < 5 W Input 1 Connectionterminals 8-, 9+ Connectable sensor typesNAMUR sensors according to DIN EN 60947-5-6 Open loop voltage8.2 V DC Short-circuit current6.5 mA Switching point1.2 ... 2.1 mA Switching hysteresis 0.2 mA Input frequency0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs Impedance1.2 kΩ Input 2 Switching pointhigh: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩlow: 0 ... 6 V DC Input frequency0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs Connectionterminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) Connectable sensor typesTwo, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V Sensor supply19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected Input 3 Start-up overrideTriggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged) Jumpering time0.1 ... 999.9 s (External trigger signal) Output Relay1 changeover contact NO, NC, COM Sensor supply24 V DC ± 10 %, 30 mA , short-circuit protected Contact loading250 V AC/2 A/ cos φ ≥ 0.740 V DC/2 A Delay≤ 20 ms (incl. calculation time) Mechanical life≥ 30.000.000 switching cycles Transfer characteristics Changing interval5 ms (Internal processing time) Time delay before availability≤ 400 ms Measuring error0 ... 40000 Hz: ≤ ±0,10% Display: ±1 digit Timer functionON-delay, OFF-delay, one shot, pulse extension Time0 ... 999.9 s ; mode of operation reversible Standard conformity Electromagnetic compatibilityacc. to EN 50081-2 / EN 50082-2 Ambient conditions Ambient temperature-25 ... 40 °C (-13 ... 104 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humiditymax. 80 %, not condensing Altitude0 ... 2000 m Operating conditionsThe device has only to be used in an indoor area. Mechanical specifications Connection assemblyCaution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. Degree of protectionIP20 Connectioncoded, removable terminals , max. core cross section 0.34 ... 2.5 mm2 Construction typemodular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module Mountingsnap-on to 35 mm standard rail or screw fixing Classifications SystemClasscode ECLASS 11.027210904 ECLASS 10.0.127210904 ECLASS 9.027210904 ECLASS 8.027210904 ECLASS 5.127210904 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFU8-DW-1.D Product Description Rotation Speed Monitor Functional safety related parameters MTTFd100 a Supply Rated voltage200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 20 VDC ... 30 VDC Fusingexternal fusing 4 A Power consumptionAC: < 5 VADC: < 5 W Input 1 Connectionterminals 8-, 9+ Connectable sensor typesNAMUR sensors according to DIN EN 60947-5-6 Open loop voltage8.2 V DC Short-circuit current6.5 mA Switching point1.2 ... 2.1 mA Switching hysteresis 0.2 mA Input frequency0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs Impedance1.2 kΩ Input 2 Switching pointhigh: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩlow: 0 ... 6 V DC Input frequency0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs Connectionterminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) Connectable sensor typesTwo, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V Sensor supply19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected Input 3 Start-up overrideTriggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged) Jumpering time0.1 ... 999.9 s (External trigger signal) Output Relay1 changeover contact NO, NC, COM Sensor supply24 V DC ± 10 %, 30 mA , short-circuit protected Contact loading250 V AC/2 A/ cos φ ≥ 0.740 V DC/2 A Delay≤ 20 ms (incl. calculation time) Mechanical life≥ 30.000.000 switching cycles Transfer characteristics Changing interval5 ms (Internal processing time) Time delay before availability≤ 400 ms Measuring error0 ... 40000 Hz: ≤ ±0,10% Display: ±1 digit Timer functionON-delay, OFF-delay, one shot, pulse extension Time0 ... 999.9 s ; mode of operation reversible Standard conformity Electromagnetic compatibilityacc. to EN 50081-2 / EN 50082-2 Ambient conditions Ambient temperature-25 ... 40 °C (-13 ... 104 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humiditymax. 80 %, not condensing Altitude0 ... 2000 m Operating conditionsThe device has only to be used in an indoor area. Mechanical specifications Connection assemblyCaution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. Degree of protectionIP20 Connectioncoded, removable terminals , max. core cross section 0.34 ... 2.5 mm2 Construction typemodular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module Mountingsnap-on to 35 mm standard rail or screw fixing Classifications SystemClasscode ECLASS 11.027210904 ECLASS 10.0.127210904 ECLASS 9.027210904 ECLASS 8.027210904 ECLASS 5.127210904 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007