Auxiliary switch block, 44 E, 4 NC EN 50011 Screw terminal for contactor relays, 4-pole !!! Phased-out product !!! Successor is SIRIUS 3RH2 Preferred successor type is >>3RH2911-1GA04<
busbar adapter Size S2, for mechanical attachment of circuit breaker and contactor Can be snapped onto standard mounting rail or for screw mounting (individual unit packaging)
Link module Electrical and mechanical For 3RV1.31/3RT1.3, 3RW3 AC operation (multi-unit packaging) !!! Phased-out product !!! Successor is SIRIUS 3RA2 Preferred successor type is >>3RA2931-1A<
Device termination connector for 3RM1 motor starter Width 22.5 mm for electrical connection of SIRIUS devices in industrial standard mounting rail enclosure
Reversing contactor assembly AC-3, 37 kW/400 V, 3-pole Size S3, Screw terminal 24 V DC Electrical and mechanical interlock !!! Phased-out product !!! Successor is SIRIUS 3RA2 Preferred successor type is >>3RA2338-8XB30-1NB3<
Position switch Metal enclosure 56 mm wide Device connection 3x (M20x 1.5) 1 NO/1 NC quick action contacts Roller lever, Metal lever and plastic roller 22 mm
**spare part** MICROMASTER 420 without filter 200-240 V 1/3 AC+10/-10% 47-63 Hz constant torque 1.1 kW overload 150% for 60 s square-law torque 1.1 kW 202x 149x 172 (HxWxD) degree of protection IP20 ambient temperature -10+50 °C without AOP/BOP
Overload relay 7...10 A For motor protection Size S0, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 Preferred successor type is >>3RU2126-1JB0<
Link module for screw terminal Electrical and mechanical complete for load feeders fuseless, Size S0 for standard mounting rail mounting consists of Wiring module busbar adapter and side modules
SIMATIC DP, bus connection plug f. PROFIBUS w. inclined cable outlet, max. 1.5 Mbaud, insulation displacement method, 15x 57.6x 39.5 mm (WxHxD), without bus terminating resistor and programming device socket
Link module Electrical and mechanical for 3RV1.21 and 3RT1.2., 3RW3 AC operation (individual unit packaging) !!! Phased-out product !!! Successor is SIRIUS 3RA2 Preferred successor type is >>3RA2921-1AA00<
Operator panel, installation in control cabinet door or front plate, can be plugged onto basic unit or extension modules, 10 LEDs for status display and 5 freely assignable keys for manual control, light gray
Overload relay 0.7...1 A For motor protection Size S00, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 Preferred successor type is >>3RU2116-0JB0<
busbar adapter 60 mm SYS UL 508 Busbar system 60 mm Bar thickness: 5/10 mm/TT profile UL rating 100A/600V Can be used in spring circuits IEC rating 100 A/690 V for SIRIUS circuit breaker for SIRIUS Size S3 for cable outlet top Cable welded 150° 153mm Adapter length 200 mm Adapter width 72 mm
Contact block With 1 contact element, 1 NO, screw terminal, 30 degrees diagonal connections, For front plate mounting !!! Phased-out product !!! Preferred successor type is >>3VL9800-2AJ00<
Load disconnector 3LD3, Iu 32 A Main switch 3-pole + N Rated operating capacity for AC-23 A at 400V 11.5kW floor mounting Basic switch with door coupling Central hole mounting 22.5mm Rotating drive black 66 x 66 mm
Power contactor, AC-3 25 A, 11 kW / 400 V 24 V DC, 0.7-1.25*US 3-pole, Size S0 Spring-type terminal !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2026-2XB40-0LA2<
RC element 24...48 V AC, 24...70 V DC Surge suppressor for mounting to contactor Size S0 Without/with auxiliary switch blocks !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2926-1CB00<
Circuit breaker size S0 for motor protection CLASS 10 A-release 0.18...0.25 A Short-circuit release 3.3 A Screw terminal Standard switching capacity !!! Phased-out product !!! Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2011-0CA10<
Overload relay 2.2...3.2 A For motor protection Size S0, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 Preferred successor type is >>3RU2126-1DB0<
Circuit breaker size S0 For starter combination Rated current 25 A Short-circuit release 325 A Screw terminal Standard switching capacity !!! Phased-out product !!! Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2321-4DC10<
Circuit breaker size S3 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 15 A Short-circuit release 225 A Screw terminal Standard switching capacity !!! Phased-out product !!! Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2742-5BD10<
Contact block with 1 contact element, 1 NC, screw terminal, 30 degrees diagonal connections, for front panel mounting ! Phased-out product! Preferred successor type is >>3VL9800-2AK00<
door-coupling rotary operating mechanism IP64 Emergency switching-off, size S00...S3 330 mm shaft with support !!! product phase-out !!! successor type is 3RV2926-1L drilling pattern changes
Overload relay 2.8...4 A For motor protection Size S0, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 Preferred successor type is >>3RU2126-1EB0<
Overload relay 14...20 A For motor protection Size S2, Class 10 Contactor mounting Main circuit: Screw terminal Auxiliary circuit: Screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 Preferred successor type is >>3RU2136-4BB0<
Overload relay 9...12 A For motor protection Size S00, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 Preferred successor type is >>3RU2116-1KB0<
Overload relay 28...40 A For motor protection Size S3, Class 10 Contactor mounting Main circuit: Screw terminal Auxiliary circuit: Screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 Preferred successor type is >>3RU2136-4FB0<
Overload relay 4.5...6.3 A For motor protection Size S0, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 Preferred successor type is >>3RU2126-1GB0<
Wiring kit Electrical and mechanical for reversing starter, Size S2 !!! Phased-out product !!! Successor is SIRIUS 3RA2 Preferred successor type is >>3RA2933-2AA1<
Wiring kit electrical for star-delta (wye-delta) starter Size S2 !!! Phased-out product !!! Successor is SIRIUS 3RA2 Preferred successor type is >>3RA2933-2BB1<
SIMATIC DP, Terminal module TM-P15S23-A1 for ET 200S for power modules, 15 mm width, Screw terminals 2x3 terminal connections with terminal access to AUX1, AUX1 continuous
Connecting cable Length 2.5 m, round, for connection of basic unit, current measuring module, current/voltage measuring module, operator panel or extension modules via the system interface
PROFIBUS FC Standard Cable GP, bus cable 2-wire, shielded, special configuration for quick assembly, Delivery unit: max. 1000 m, minimum order quantity 20 m sold by the meter
SINAMICS V20 200-240 V 1-phase AC -10/+10 rated power 2.2 kW with 150% overload for 60 sec. unfiltered I/O: 4 DI, 2 DO,2 AI, 1 AQ fieldbus: USS/MODBUS RTU with built-in BOP degree of protection IP20/UL open size: C 184x182x169 (WxHxD)
SINAMICS V20 200-240 V 1-phase AC -10/+10 rated power 3.0 kW with 150% overload for 60 sec. unfiltered I/O: 4 DI, 2 DO,2 AI, 1 AQ fieldbus: USS/MODBUS RTU with built-in BOP degree of protection IP20/UL open size: C 184x182x169 (WxHxD)
200-240 V 1-phase AC -10/+10 rated power 1.1 kW with 150% overload for 60 s unfiltered I/O: 4 DI, 2 DO, 2 AI, 1 AO fieldbus: USS/MODBUS RTU with built-in BOP degree of protection IP20/UL open size: B 140x160x165 (WxHxD)
Busbar system, accessories Busbar center-to-center spacing 40, 60 mm Cover profile for Busbar Length 1000 mm Thickness of the busbars: 5 mm Width of the busbars: 12 mm