Connecting cable Length 0.3 m, flat, for connection of basic unit, current measuring module, current/voltage measuring module, operator panel or extension modules via the system interface
Analog monitoring relay Phase failure and sequence Adjustable undervoltage Asymmetry 20% fixed 3 x 160 to 690 V 50 to 60 Hz AC Hysteresis 5% fixed Delay time 0-20 s 2 change-over contacts screw terminal Successor product for 3UG3013-1B...
Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3522-1AC..
Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3522-1AL20, 3UG3522-1AG20 and 3UG3522-1AC48-0AA1
Device termination connector for 3SK1 safety relay Width 22.5 mm for electrical connection of SIRIUS devices in industrial standard mounting rail enclosure
Connection terminal set, 3-pole for flat bars to 32x 20 mm Busbar center-to-center spacing 60 mm UL 508A *** Cover 8US1922-1GC00 to be ordered separately ***
Busbar system Busbar center-to-center spacing 60 mm Device adapter, Width: 45 mm Bar thickness: 5.10 mm+TT profile for circuit breaker, Contactor Overload relay, Motor feeders S00, S0, Length 182 mm with 1 DIN rail 35 mm, up to 25 A
Busbar system Busbar center-to-center spacing 40 mm Device adapter, Width: 108 mm Bar thickness: 5+10 mm for circuit breaker 3VL1 up to 160 A with terminal cover Length 175 mm
circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=125A, rated current IR=100...125A, overload protection, II=625...1250A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=63A, rated current Ir=63A, overload protection II=600A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
Circuit breaker size S00 for motor protection, CLASS 10 A-release 2.8...4 A N release 52 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC
Circuit breaker size S00 for motor protection, CLASS 10 A-release 2.2...3.2 A N release 42 A 1 NO+1 NC transverse Screw terminal Standard switching capacity
VIB321 measured value acquisition module 10-channel, can be used for -Vibrations -Strains -Positions -2 triggers -DC (4...20 mA/0...10 V) Buffer output BNC 10-channel, additional analog inputs 10-channel (4...20 mA) (use for protection and analysis system)
VIB321 measured value acquisition module 10-channel, can be used for -Vibrations -Strains -Positions -2 triggers -DC (4...20 mA/0...10 V) Buffer output BNC 10-channel, additional analog inputs 10-channel (4...20 mA) (use for protection and analysis system)
VIB340B backplane for VIB3000 for accommodating up to -2 VIB310 -6 VIB320/VIB321 -1 VIB330 Power supply 2x24 V DC (connector enclosed), Cable inlet on the front
SITOP SEL1200 selectivity module 8-channel switching characteristic input: 24 V DC/60 A output: 24 V DC/8 x 10 A threshold adjustable 2-10 A with monitoring interface *Ex approval no longer