Multi i/o bar din Riello UPS - Part number: RIEYSKCIO2B
غير متوفر - طلب متأخر
لطلب من الشركة المصنعة
262.63 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل

Multi i/o bar din Riello UPS - Part number: RIEYSKCIO2B

Riello UPS

Multi I/O interface in DIN rail version for UPS integration with control systems, configurable relay inputs/outputs and Modbus/Jbus communication over RS485. It enables multiple serial links, multi-polling and monitoring via RS232 according to the installed configuration. Riello compatibility: Multi I/O and Riello UPS systems prepared for I/O interfaces. Multi I/O interface in DIN rail version for UPS integration with control systems, configurable relay inputs/outputs and Modbus/Jbus communication over RS485. It enables multiple serial links, multi-polling and monitoring via RS232 according to the installed configuration. Riello compatibility: Multi I/O and Riello UPS systems prepared for I/O interfaces.

شبكات MPN YSKCIO2B, RIEYSKCIO2B
EAN 8023251009778
رمز النظام المنسق 85072000
Weight 1.5 kg
الوزن الحجمي 2.68 kg

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

262.63 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
نحن موزّع معتمد لـ Riello UPS
شحن سريع مجاني إلى الولايات المتحدة الأمريكية
Loader...
عرض جميع خدمات الشحن
اطلب عرض أسعار لمعرفة تاريخ التسليم

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

معلومات المنتج

وصف

<div class="row"> <div class="col-xs-12"> <h3>Multi I/O interface DIN rail version</h3> <p>Communication interface designed to integrate the UPS with control and monitoring systems through configurable input and output signals. Its main function is to transform UPS events, statuses and alarms into contacts or data that can be used by supervisors, PLCs and BMS systems. The card supports multiple serial connections and allows UPS polling by more than one device, a useful feature in installations with firewalls, separate networks or multiple supervision systems. Communication with the UPS is via RS232, while dialogue on RS485 lines can use the Modbus/Jbus protocol.</p> <h4>Technical features</h4> <ul> <li>Configurable relay inputs and outputs for control and monitoring.</li> <li>Communication with UPS via RS232.</li> <li>Modbus/Jbus protocol on RS485 line.</li> <li>Possibility to connect two devices to a single UPS communication port.</li> <li>Indicated format: DIN rail version; mechanical details not reported.</li> </ul> <h4>Integration process</h4> <p>Integration requires contact wiring, serial communication setup and event testing. It is recommended to document configured inputs, outputs and logic for maintenance and future troubleshooting.</p> <h4>Configuration software</h4> <p>Configuration depends on the interface settings and on the supervision software connected to the serial or Modbus/Jbus line. Event mapping should follow the technical manual. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Multi I/O and Riello UPS systems prepared for I/O interfaces.</p> </div> </div> <div class="row"> <div class="col-xs-12"> <h3>Multi I/O interface DIN rail version</h3> <p>Communication interface designed to integrate the UPS with control and monitoring systems through configurable input and output signals. Its main function is to transform UPS events, statuses and alarms into contacts or data that can be used by supervisors, PLCs and BMS systems. The card supports multiple serial connections and allows UPS polling by more than one device, a useful feature in installations with firewalls, separate networks or multiple supervision systems. Communication with the UPS is via RS232, while dialogue on RS485 lines can use the Modbus/Jbus protocol.</p> <h4>Technical features</h4> <ul> <li>Configurable relay inputs and outputs for control and monitoring.</li> <li>Communication with UPS via RS232.</li> <li>Modbus/Jbus protocol on RS485 line.</li> <li>Possibility to connect two devices to a single UPS communication port.</li> <li>Indicated format: DIN rail version; mechanical details not reported.</li> </ul> <h4>Integration process</h4> <p>Integration requires contact wiring, serial communication setup and event testing. It is recommended to document configured inputs, outputs and logic for maintenance and future troubleshooting.</p> <h4>Configuration software</h4> <p>Configuration depends on the interface settings and on the supervision software connected to the serial or Modbus/Jbus line. Event mapping should follow the technical manual. During commissioning, technicians should also record wiring, protection coordination, alarm mapping and final operating settings so that future maintenance can reproduce the same safe operating conditions. This approach improves traceability in professional installations and supports correct interaction between the accessory, the UPS and the protected load.</p> <h4>Riello compatibility</h4> <p>The Riello compatibility or reference series is: Multi I/O and Riello UPS systems prepared for I/O interfaces.</p> </div> </div>

مواصفات تقنية

Type of accessory/spare part
Other

مراجعات شركتنا