VBG-PB-K20-DMD-BV PEPPERL+FUCHS - Part number: 205322
PEPPERL+FUCHS
AS-Interface gateway VBG-PB-K20-DMD-BV VBG-PB-K20-DMD-BV Connection to PROFIBUS DP 2 AS-Interface networks PROFIBUS DP V1 support Easy commissioning and fault diagnosis via LEDs and graphic display Earth fault detection AS-Interface noise detection AS-Interface gateway VBG-PB-K20-DMD-BV VBG-PB-K20-DMD-BV Connection to PROFIBUS DP 2 AS-Interface networks PROFIBUS DP V1 support Easy commissioning and fault diagnosis via LEDs and graphic display Earth fault detection AS-Interface noise detection
شبكات MPN 205322, PEP205322, VBG-PB-K20-DMD-BV
رمز النظام المنسق 85176900
Weight
0.42 kg
صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
مدفوعات آمنة
و اكثر بكثير
نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا
12 شهور ضمان
هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا
الإرجاع متاح خلال 30 يومًا
يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.
معلومات المنتج
وصف
Datasheet excerpt: Technical data of
VBG-PB-K20-DMD-BV
Product Description
PROFIBUS Gateway, double master for 2 AS-Interface networks
General specifications
AS-Interface specificationV3.0
PLC-Functionalityactivateable
Earth fault detectionintegrated
EMC monitoringintegrated
Diagnostics functionExtended function via display
UL File NumberE223772
Indicators/operating means
DisplayIlluminated graphical LC display for addressing and error messages
LED PROFIBUSPROFIBUS master detected; LED green
LED AS-i ACTIVEAS-Interface operation normal; LED green
LED CONFIG ERRconfiguration error; LED red
LED PRG ENABLEautom. programming; LED green
LED POWERvoltage ON; LED green
LED PRJ MODEprojecting mode active; LED yellow
LED U AS-iAS-Interface voltage; LED green
Switch SETSelection and setting of a slave address
OK buttonMode selection traditional-graphical/confirmation
Button MODEMode selection PRJ-operation/save configuration/cursor
ESC buttonMode selection traditional-graphical/cancel
Electrical specifications
Insulation voltage≥ 500 V
Rated operating voltagefrom AS-Interface
Rated operating current≤ 180 mA from AS-Interface
Interface
Interface typeRS-485
ProtocolPROFIBUS DP V1
Transfer rate9.6 kBit/s ... 12 MBit/s , Automatic baud rate detection
Connection
PROFIBUSSub-D interface
AS-Interfacespring terminals, removable
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Standard conformity
Electromagnetic compatibilityEN 61326
Degree of protectionEN 60529:2000
AS-InterfaceEN 62026-2:2013
Ambient conditions
Ambient temperature0 ... 55 °C (32 ... 131 °F)
Storage temperature-15 ... 75 °C (5 ... 167 °F)
Mechanical specifications
Degree of protectionIP20
Mass420 g
Construction typeLow profile housing , Stainless steel
Classifications
SystemClasscode
ECLASS 11.027242607
ECLASS 10.0.127242607
ECLASS 9.027242607
ECLASS 8.027242607
ECLASS 5.127242607
ETIM 8.0EC001603
ETIM 7.0EC001603
ETIM 6.0EC001603
ETIM 5.0EC001603
UNSPSC 12.139121535
Datasheet excerpt: Technical data of
VBG-PB-K20-DMD-BV
Product Description
PROFIBUS Gateway, double master for 2 AS-Interface networks
General specifications
AS-Interface specificationV3.0
PLC-Functionalityactivateable
Earth fault detectionintegrated
EMC monitoringintegrated
Diagnostics functionExtended function via display
UL File NumberE223772
Indicators/operating means
DisplayIlluminated graphical LC display for addressing and error messages
LED PROFIBUSPROFIBUS master detected; LED green
LED AS-i ACTIVEAS-Interface operation normal; LED green
LED CONFIG ERRconfiguration error; LED red
LED PRG ENABLEautom. programming; LED green
LED POWERvoltage ON; LED green
LED PRJ MODEprojecting mode active; LED yellow
LED U AS-iAS-Interface voltage; LED green
Switch SETSelection and setting of a slave address
OK buttonMode selection traditional-graphical/confirmation
Button MODEMode selection PRJ-operation/save configuration/cursor
ESC buttonMode selection traditional-graphical/cancel
Electrical specifications
Insulation voltage≥ 500 V
Rated operating voltagefrom AS-Interface
Rated operating current≤ 180 mA from AS-Interface
Interface
Interface typeRS-485
ProtocolPROFIBUS DP V1
Transfer rate9.6 kBit/s ... 12 MBit/s , Automatic baud rate detection
Connection
PROFIBUSSub-D interface
AS-Interfacespring terminals, removable
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Standard conformity
Electromagnetic compatibilityEN 61326
Degree of protectionEN 60529:2000
AS-InterfaceEN 62026-2:2013
Ambient conditions
Ambient temperature0 ... 55 °C (32 ... 131 °F)
Storage temperature-15 ... 75 °C (5 ... 167 °F)
Mechanical specifications
Degree of protectionIP20
Mass420 g
Construction typeLow profile housing , Stainless steel
Classifications
SystemClasscode
ECLASS 11.027242607
ECLASS 10.0.127242607
ECLASS 9.027242607
ECLASS 8.027242607
ECLASS 5.127242607
ETIM 8.0EC001603
ETIM 7.0EC001603
ETIM 6.0EC001603
ETIM 5.0EC001603
UNSPSC 12.139121535