AS-Interface safety module VAA-2E-KE1-S VAA-2E-KE1-S 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch Housing with removable terminals Communication monitoring Power supply of inputs from the module Function display for bus and inputs Cross-circuit detection Addressing jack AS-Interface safety module VAA-2E-KE1-S VAA-2E-KE1-S 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch Housing with removable terminals Communication monitoring Power supply of inputs from the module Function display for bus and inputs Cross-circuit detection Addressing jack

شبكات MPN 134088, PEP134088, VAA-2E-KE1-S
رمز النظام المنسق 85371091
Weight N/A

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

261.00 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
نحن شريك متخصص لـ PEPPERL+FUCHS
شحن سريع مجاني إلى الولايات المتحدة الأمريكية
Loader...
عرض جميع خدمات الشحن
اطلب عرض أسعار لمعرفة تاريخ التسليم

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

معلومات المنتج

وصف

Datasheet excerpt: Technical data of  VAA-2E-KE1-S Product Description KE1 safety module for the control cabinet, 2 Safety-related inputs General specifications Node typeSafety node AS-Interface specificationV2.11 Required gateway specification≥ V2.0 ProfileS-0.B IO code0 ID codeB ID1 codeF ID2 code0 UL File NumberE87056 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 / PL e MTTFd200 a Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0 LED PWRAS-Interface voltage; LED green LED INswitching state (input); 2 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V PELV from AS-Interface Rated operating current≤ 70 mA Protection classIII Input Number/Type2 safety-related inputs for mechanical contacts, cross-circuit monitored: 2 single-channel contacts: up to category 2 / PL c according to EN ISO 13849-1 or 1 two-channel contact: up to category 4 / PL e according to EN ISO 13849-1 Cable length must not exceed 300 m per input. Supplyfrom AS-Interface Voltage20 ... 30 V DC pulsed Current loading capacityinput current limited ≤ 15 mA,overload and short-circuit resistant Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013+A1:2019 Standard conformity Insulation coordinationEN 50178:1998 Electromagnetic compatibilityEN 61000-6-2, EN 61000-4-5 1 kV asymmetric, criterion B, EN 61000-6-4 Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013+A1:2019 Electrical safetyEN 50178:1998 IEC 60204-1:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Functional safetyCategory 4 / PL e to EN ISO 13849-1:2015 SIL 3 according to IEC 62061:2015 and IEC 61508 Part 1-7:2010 StandardsNFPA 79:2002 Ambient conditions Ambient temperature-25 ... 50 °C (-13 ... 122 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Shock and impact resistance10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Mechanical specifications Degree of protectionIP20 Connectionremovable terminals, terminal connection ≤ 2.5 mm2 Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-2E-KE1-S Product Description KE1 safety module for the control cabinet, 2 Safety-related inputs General specifications Node typeSafety node AS-Interface specificationV2.11 Required gateway specification≥ V2.0 ProfileS-0.B IO code0 ID codeB ID1 codeF ID2 code0 UL File NumberE87056 Functional safety related parameters Safety Integrity Level (SIL)SIL 3 / PL e MTTFd200 a Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0 LED PWRAS-Interface voltage; LED green LED INswitching state (input); 2 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V PELV from AS-Interface Rated operating current≤ 70 mA Protection classIII Input Number/Type2 safety-related inputs for mechanical contacts, cross-circuit monitored: 2 single-channel contacts: up to category 2 / PL c according to EN ISO 13849-1 or 1 two-channel contact: up to category 4 / PL e according to EN ISO 13849-1 Cable length must not exceed 300 m per input. Supplyfrom AS-Interface Voltage20 ... 30 V DC pulsed Current loading capacityinput current limited ≤ 15 mA,overload and short-circuit resistant Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013+A1:2019 Standard conformity Insulation coordinationEN 50178:1998 Electromagnetic compatibilityEN 61000-6-2, EN 61000-4-5 1 kV asymmetric, criterion B, EN 61000-6-4 Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013+A1:2019 Electrical safetyEN 50178:1998 IEC 60204-1:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Functional safetyCategory 4 / PL e to EN ISO 13849-1:2015 SIL 3 according to IEC 62061:2015 and IEC 61508 Part 1-7:2010 StandardsNFPA 79:2002 Ambient conditions Ambient temperature-25 ... 50 °C (-13 ... 122 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Shock and impact resistance10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Mechanical specifications Degree of protectionIP20 Connectionremovable terminals, terminal connection ≤ 2.5 mm2 Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535