VBA-4E4A-KE-ZEJQ/E2L PEPPERL+FUCHS - Part number: 217801
غير متوفر - طلب متأخر
لطلب من الشركة المصنعة
302.39 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل

VBA-4E4A-KE-ZEJQ/E2L PEPPERL+FUCHS - Part number: 217801

PEPPERL+FUCHS

AS-Interface sensor/actuator module VBA-4E4A-KE-ZEJQ/E2L VBA-4E4A-KE-ZEJQ/E2L Housing with removable, mechanical and color coded terminals Communication monitoring Inputs for 2- and 3-wire sensors Addressing jack Power supply of outputs from the external auxiliary voltage Selectable supply to the sensors: External or from the module Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs Red LED per channel, lights up in the event of output overload Switchable lead breakage detection (outputs) AS-Interface sensor/actuator module VBA-4E4A-KE-ZEJQ/E2L VBA-4E4A-KE-ZEJQ/E2L Housing with removable, mechanical and color coded terminals Communication monitoring Inputs for 2- and 3-wire sensors Addressing jack Power supply of outputs from the external auxiliary voltage Selectable supply to the sensors: External or from the module Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs Red LED per channel, lights up in the event of output overload Switchable lead breakage detection (outputs)

شبكات MPN 217801, PEP217801, VBA-4E4A-KE-ZEJQ/E2L
رمز النظام المنسق 85371091
Weight 0.15 kg

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

302.39 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
نحن شريك متخصص لـ PEPPERL+FUCHS
شحن سريع مجاني إلى الولايات المتحدة الأمريكية
Loader...
عرض جميع خدمات الشحن
اطلب عرض أسعار لمعرفة تاريخ التسليم

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

معلومات المنتج

وصف

Datasheet excerpt: Technical data of  VBA-4E4A-KE-ZEJQ/E2L Product Description KE switch cabinet module4 inputs and 4 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required master specification≥ V3.0 UL File NumberE223772 Functional safety related parameters MTTFd190 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTError display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTswitching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 35 mA (without sensors) / max. 190 mA Protection classIII Surge protectionUEXT, UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) Voltage21 ... 31 V DC (INT) Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT) Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current2 A per output, sum 4A (TB ≤ 40 °C) 0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap) Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2004 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.A.7 IO code7 ID codeA ID1 code7 ID2 code7 Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass150 g MountingDIN mounting rail Tightening torque of clamping screws0.5 Nm ... 0.6 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E4A-KE-ZEJQ/E2L Product Description KE switch cabinet module4 inputs and 4 outputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required master specification≥ V3.0 UL File NumberE223772 Functional safety related parameters MTTFd190 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTError display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs LED INTInternal input supply active; LED green LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage LED INswitching state (input); 4 LED yellow LED OUTswitching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption Electrical specifications Auxiliary voltage (input)12 ... 30 V DC PELV Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 35 mA (without sensors) / max. 190 mA Protection classIII Surge protectionUEXT, UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) Voltage21 ... 31 V DC (INT) Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT) Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 1 ms (input/AS-Interface) Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current2 A per output, sum 4A (TB ≤ 40 °C) 0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap) Voltage≥ (UAUX - 0.5 V) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2004 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Programming instructions ProfileS-7.A.7 IO code7 ID codeA ID1 code7 ID2 code7 Data bits (function via AS-Interface) input output D0 IN1 O1 D1 IN2 O2 D2 IN3 O3 D3 IN4 O4 Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass150 g MountingDIN mounting rail Tightening torque of clamping screws0.5 Nm ... 0.6 Nm Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

مراجعات شركتنا