VBA-4E4E-G11-ZAJ-F PEPPERL+FUCHS - Part number: 251408
غير متوفر - طلب متأخر
لطلب من الشركة المصنعة
315.77 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل

VBA-4E4E-G11-ZAJ-F PEPPERL+FUCHS - Part number: 251408

PEPPERL+FUCHS

AS-Interface sensor module VBA-4E4E-G11-ZAJ-F VBA-4E4E-G11-ZAJ-F Inputs for 2-, 3-, and 4-wire sensors Supply of sensors from AS-Interface Function display for bus and inputs Degree of protection IP68 / IP69K Communication monitoring Cable piercing method with gold plated contact pins AS-Interface POWER24 AS-Interface sensor module VBA-4E4E-G11-ZAJ-F VBA-4E4E-G11-ZAJ-F Inputs for 2-, 3-, and 4-wire sensors Supply of sensors from AS-Interface Function display for bus and inputs Degree of protection IP68 / IP69K Communication monitoring Cable piercing method with gold plated contact pins AS-Interface POWER24

شبكات MPN 251408, PEP251408, VBA-4E4E-G11-ZAJ-F
رمز النظام المنسق 85371091
Weight 0.2 kg

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

315.77 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
نحن شريك متخصص لـ PEPPERL+FUCHS
شحن سريع مجاني إلى الولايات المتحدة الأمريكية
Loader...
عرض جميع خدمات الشحن
اطلب عرض أسعار لمعرفة تاريخ التسليم

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

معلومات المنتج

وصف

Datasheet excerpt: Technical data of  VBA-4E4E-G11-ZAJ-F Product Description G11 module2 x 4 inputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 ProfileS-0.A.2 IO code0 ID codeA ID1 codeNode 1: 1Node 2: 2 ID2 code2 UL File NumberE223772 Functional safety related parameters MTTFd120 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULT2 Dual LEDs green/redgreen: AS-Interface voltagered: Communication erroryellow/red flashing: Address 0green/red flashing: Sensor supply overload LED INswitching state (input); 8 LED yellow Electrical specifications Rated operating voltage18,0 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA (without sensors) / max. 280 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type2x 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2x 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage12 ... 31 V Current loading capacity≤ 200 mA, overload and short-circuit protected Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 1 ms (input/AS-Interface) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 6 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface: AS-Interface flat cable Inputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E4E-G11-ZAJ-F Product Description G11 module2 x 4 inputs General specifications Node typeA/B node AS-Interface specificationV3.0 Required gateway specification≥ V2.1 ProfileS-0.A.2 IO code0 ID codeA ID1 codeNode 1: 1Node 2: 2 ID2 code2 UL File NumberE223772 Functional safety related parameters MTTFd120 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED AS-i/FAULT2 Dual LEDs green/redgreen: AS-Interface voltagered: Communication erroryellow/red flashing: Address 0green/red flashing: Sensor supply overload LED INswitching state (input); 8 LED yellow Electrical specifications Rated operating voltage18,0 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA (without sensors) / max. 280 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type2x 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2x 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage12 ... 31 V Current loading capacity≤ 200 mA, overload and short-circuit protected Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 1 ms (input/AS-Interface) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 6 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles Pollution degree3 Mechanical specifications Degree of protectionIP68 / IP69K ConnectionAS-Interface: AS-Interface flat cable Inputs: M12 round connector Material HousingPBT PC Mounting screwStainless steel 1.4305 / AISI 303 Mass200 g Tightening torque, housing screws1.8 Nm Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

مراجعات شركتنا