VBA-4E4E-G12-ZAJ PEPPERL+FUCHS - Part number: 200524
غير متوفر - طلب متأخر
لطلب من الشركة المصنعة
373.07 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل

VBA-4E4E-G12-ZAJ PEPPERL+FUCHS - Part number: 200524

PEPPERL+FUCHS

AS-Interface sensor module VBA-4E4E-G12-ZAJ VBA-4E4E-G12-ZAJ A/B node with extended addressing possibility for up to 62 nodes One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring, configurable Inputs for 2-, 3-, and 4-wire sensors DIN rail mounting AS-Interface certificate Automatic addressing with latest masters in the event of replacement AS-Interface sensor module VBA-4E4E-G12-ZAJ VBA-4E4E-G12-ZAJ A/B node with extended addressing possibility for up to 62 nodes One-piece housing with stainless steel base Installation without tools Metal threaded inserts with SPEEDCON technology Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring, configurable Inputs for 2-, 3-, and 4-wire sensors DIN rail mounting AS-Interface certificate Automatic addressing with latest masters in the event of replacement

شبكات MPN 200524, PEP200524, VBA-4E4E-G12-ZAJ
رمز النظام المنسق 85371091
Weight 0.23 kg

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

373.07 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
نحن شريك متخصص لـ PEPPERL+FUCHS
شحن سريع مجاني إلى الولايات المتحدة الأمريكية
Loader...
عرض جميع خدمات الشحن
اطلب عرض أسعار لمعرفة تاريخ التسليم

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

اطلب الخدمة الفنية المخصصة لك

اعتمد على فريقنا الفني الخبير للحصول على مجموعة من الخدمات الشخصية: الإصلاح والبرمجة والصيانة وغير ذلك الكثير.

معلومات المنتج

وصف

Datasheet excerpt: Technical data of  VBA-4E4E-G12-ZAJ Product Description G12 flat module2 x 4 inputs (PNP) General specifications Node typeDouble A/B slave AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd60 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED PWR/FAULT2 Dual LEDs green/redgreen: AS-Interface voltagered: Communication erroryellow/red flashing: Address 0green/red flashing: Sensor supply overload LED INswitching state (input); 8 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA (without sensors) / max. 280 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Input Number/Type2x 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2x 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA, overload and short-circuit protected Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 6 mA Signal delay< 1 ms (input/AS-Interface) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-0.A.2 IO code0 ID codeA ID1 codeSlave 1 Slave 21 2 ID2 code2 Data bits (function via AS-Interface)Input slave 1 input slave 2 D0IN1.1 IN2.1 D1IN1.2 IN2.2 D2IN1.3 IN2.3 D3IN1.4 IN2.4 Parameter bits (programmable via AS-i)function P0not used P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 Connectioncable piercing methodflat cable yellowinputs: M12 round connector Material HousingPBT Mass230 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E4E-G12-ZAJ Product Description G12 flat module2 x 4 inputs (PNP) General specifications Node typeDouble A/B slave AS-Interface specificationV3.0 Required gateway specification≥ V2.1 UL File NumberE223772 Functional safety related parameters MTTFd60 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED PWR/FAULT2 Dual LEDs green/redgreen: AS-Interface voltagered: Communication erroryellow/red flashing: Address 0green/red flashing: Sensor supply overload LED INswitching state (input); 8 LED yellow Electrical specifications Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 80 mA (without sensors) / max. 280 mA Protection classIII Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral Input Number/Type2x 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2x 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 200 mA, overload and short-circuit protected Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 6 mA Signal delay< 1 ms (input/AS-Interface) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2 Emitted interferenceEN 61000-6-4:2007 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2005 EN 62026-2:2013 Programming instructions ProfileS-0.A.2 IO code0 ID codeA ID1 codeSlave 1 Slave 21 2 ID2 code2 Data bits (function via AS-Interface)Input slave 1 input slave 2 D0IN1.1 IN2.1 D1IN1.2 IN2.2 D2IN1.3 IN2.3 D3IN1.4 IN2.4 Parameter bits (programmable via AS-i)function P0not used P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles Pollution degree3 Mechanical specifications Degree of protectionIP67 Connectioncable piercing methodflat cable yellowinputs: M12 round connector Material HousingPBT Mass230 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

مراجعات شركتنا