OCS2000-M1K-N2 PEPPERL+FUCHS - Part number: 106529
غير متوفر - طلب متأخر
لطلب من الشركة المصنعة
684.23 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل

OCS2000-M1K-N2 PEPPERL+FUCHS - Part number: 106529

PEPPERL+FUCHS

Retroreflective sensor, NAMUR OCS2000-M1K-N2 OCS2000-M1K-N2 ATEX-, IECEX approval for zone 20 (Dust) and zone 1 (Gas) Intrinsically safe, Ex op is ia IIC T6 Gb/IIIC T 135 °C Da Glare protected with polarization filter Adjustable sensor head Scratch resistant mineral glass lens Retroreflective sensor, NAMUR OCS2000-M1K-N2 OCS2000-M1K-N2 ATEX-, IECEX approval for zone 20 (Dust) and zone 1 (Gas) Intrinsically safe, Ex op is ia IIC T6 Gb/IIIC T 135 °C Da Glare protected with polarization filter Adjustable sensor head Scratch resistant mineral glass lens

شبكات MPN 106529, PEP106529, OCS2000-M1K-N2
رمز النظام المنسق 85365090
Weight 0.1 kg

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

684.23 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
نحن شريك متخصص لـ PEPPERL+FUCHS
شحن سريع مجاني إلى الولايات المتحدة الأمريكية
Loader...
عرض جميع خدمات الشحن
اطلب عرض أسعار لمعرفة تاريخ التسليم

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

اطلب الخدمة الفنية المخصصة لك

اعتمد على فريقنا الفني الخبير للحصول على مجموعة من الخدمات الشخصية: الإصلاح والبرمجة والصيانة وغير ذلك الكثير.

معلومات المنتج

وصف

Datasheet excerpt: Technical data of  OCS2000-M1K-N2 Product Description NAMUR retroreflective sensor, special design, 2 m detection range, red light, light/dark on, DC version, NAMUR output, terminal compartment General specifications Effective detection range0 ... 2 m Reflector distance100 ... 2000 mm Threshold detection range2 m Reference targetRetro-reflector C110-2 Light sourceLED , 660 nm Light typemodulated visible red light Polarization filteryes Ambient light limit≤ 10000 Lux sun light ≤ 7500 Lux halogen light Functional safety related parameters MTTFd1319 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Function indicatorLED yellow: switching state Electrical specifications Operating voltage6 ... 20 V DC (Ri 0 Ohm) Ripple5 % Time delay before availability20 ms Output Switching typelight/dark on, programmable Signal output1 NAMUR output NC/NO programmable Switching voltage8 V DC (Ri 1 kΩ) Switching frequency≤ 100 Hz Current consumption Reference target detectedconnection 1, 2: ≥ 2.2 mA connection 1, 4: ≤ 1 mA Reference target not detectedconnection 1, 2: ≤ 1 mA connection 1, 4: ≥ 2.2 mA Response time5 ms Conformity Product standardEN 60947-5-2 Compliance with standards and directives Standard conformity StandardsEN 60947-5-6:2000 Approvals and certificates FM approval Approved forIS / I,II,III / 1 / ABCDEFG / T5 - 116-0110; EntityNI / I / 2 / ABCD / T6Entity Parameters:VMax = 12.6 V, IMax = 20 mA, Ci = 1.11 µF, Li = 0 mH (Groups A, B, C, D, E, F, G).VMax = 15.5 V, IMax = 52 mA, Ci = 1.11 µF, Li = 0 mH (Groups C, D, E, F, G). CSA approval Approved forClass I, Division 2, Groups A, B, C and DRated 20V (max), 50mA.These sensors are suitable for installation in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit, as acceptable to the local inspection authority having jurisdiction. CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 80 °C (-40 ... 176 °F) Mechanical specifications Housing width30 mm Housing height30 mm Housing depth102 mm Degree of protectionIP67 according to EN 60529, Class II insulation ConnectionM16 terminal compartment, core cross section ≤ 2.5 mm2 Material HousingPBT Optical faceScratch resistant mineral glass lens Mass100 g ATEX G EC-Type Examination CertificatePTB 01 ATEX 2203 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. ATEX D EC-Type Examination CertificateZELM 03 ATEX 0196 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 20/21: II 1D Ex ia IIIC T 135°C Da Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the surface temperature class. In applications where high levels of charge are expected (e.g. electrostatic paint, foil manufacture, dust extraction, mechanical friction), structural measures must be taken to limit the surface area of the plastic housing exposed to this charge to approximately 15 cm2 in order to avoid propagating brush discharge. When setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. IECEx G Certificate numberIECEx PTB 12.0060 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. IECEx D Certificate numberIECEx ZLM 12.0005X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingEx ia IIIC T135°C Da StandardsIEC 60079-0:2011 IEC 60079-11:2011 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsWhen setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. Classifications SystemClasscode ECLASS 11.027270902 ECLASS 10.0.127270902 ECLASS 9.027270902 ECLASS 8.027270902 ECLASS 5.127270902 ETIM 8.0EC002717 ETIM 7.0EC002717 ETIM 6.0EC002717 ETIM 5.0EC002717 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  OCS2000-M1K-N2 Product Description NAMUR retroreflective sensor, special design, 2 m detection range, red light, light/dark on, DC version, NAMUR output, terminal compartment General specifications Effective detection range0 ... 2 m Reflector distance100 ... 2000 mm Threshold detection range2 m Reference targetRetro-reflector C110-2 Light sourceLED , 660 nm Light typemodulated visible red light Polarization filteryes Ambient light limit≤ 10000 Lux sun light ≤ 7500 Lux halogen light Functional safety related parameters MTTFd1319 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means Function indicatorLED yellow: switching state Electrical specifications Operating voltage6 ... 20 V DC (Ri 0 Ohm) Ripple5 % Time delay before availability20 ms Output Switching typelight/dark on, programmable Signal output1 NAMUR output NC/NO programmable Switching voltage8 V DC (Ri 1 kΩ) Switching frequency≤ 100 Hz Current consumption Reference target detectedconnection 1, 2: ≥ 2.2 mA connection 1, 4: ≤ 1 mA Reference target not detectedconnection 1, 2: ≤ 1 mA connection 1, 4: ≥ 2.2 mA Response time5 ms Conformity Product standardEN 60947-5-2 Compliance with standards and directives Standard conformity StandardsEN 60947-5-6:2000 Approvals and certificates FM approval Approved forIS / I,II,III / 1 / ABCDEFG / T5 - 116-0110; EntityNI / I / 2 / ABCD / T6Entity Parameters:VMax = 12.6 V, IMax = 20 mA, Ci = 1.11 µF, Li = 0 mH (Groups A, B, C, D, E, F, G).VMax = 15.5 V, IMax = 52 mA, Ci = 1.11 µF, Li = 0 mH (Groups C, D, E, F, G). CSA approval Approved forClass I, Division 2, Groups A, B, C and DRated 20V (max), 50mA.These sensors are suitable for installation in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit, as acceptable to the local inspection authority having jurisdiction. CCC approvalCCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-40 ... 80 °C (-40 ... 176 °F) Mechanical specifications Housing width30 mm Housing height30 mm Housing depth102 mm Degree of protectionIP67 according to EN 60529, Class II insulation ConnectionM16 terminal compartment, core cross section ≤ 2.5 mm2 Material HousingPBT Optical faceScratch resistant mineral glass lens Mass100 g ATEX G EC-Type Examination CertificatePTB 01 ATEX 2203 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. ATEX D EC-Type Examination CertificateZELM 03 ATEX 0196 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany CE markingCE0102 ATEX markingZone 20/21: II 1D Ex ia IIIC T 135°C Da Directive conformity2014/34/EU StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the surface temperature class. In applications where high levels of charge are expected (e.g. electrostatic paint, foil manufacture, dust extraction, mechanical friction), structural measures must be taken to limit the surface area of the plastic housing exposed to this charge to approximately 15 cm2 in order to avoid propagating brush discharge. When setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. IECEx G Certificate numberIECEx PTB 12.0060 X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 Effective internal capacitance Cimax. 75 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsRefer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances. IECEx D Certificate numberIECEx ZLM 12.0005X ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany IECEx markingEx ia IIIC T135°C Da StandardsIEC 60079-0:2011 IEC 60079-11:2011 Effective internal capacitance Cimax. 1200 nF Effective internal inductance Linegligibly small GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. Special conditions Protection against dangerous electrostatic chargingThe device must be installed such that electrostatic discharges can be avoided. If the device is installed in accordance with the instructions provided by the manufacturer, no dangerous electrostatic charge is to be expected given the properties of the device. Protection from mechanical dangerWhen used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Degree of protection required when installing connecting componentsIP20 according to IEC 60529:2001 Other conditionsWhen setting up a partition between different zones, appropriate measures must be taken to ensure that the components installed in the partition isolate the zones completely from one another. Classifications SystemClasscode ECLASS 11.027270902 ECLASS 10.0.127270902 ECLASS 9.027270902 ECLASS 8.027270902 ECLASS 5.127270902 ETIM 8.0EC002717 ETIM 7.0EC002717 ETIM 6.0EC002717 ETIM 5.0EC002717 UNSPSC 12.139121528

مراجعات شركتنا