LA61/115 PEPPERL+FUCHS - Part number: 911621
متوفرة عند الطلب

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

LA61/115 PEPPERL+FUCHS - Part number: 911621

PEPPERL+FUCHS

Thru-beam sensor LA61/LK61-Z/31/115 LA61/LK61-Z/31/115 Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360° high visibility LEDs Programmable ON-delay, OFF-delay, and One-shot timers Version for universal voltages Relay output Thru-beam sensor LA61/LK61-Z/31/115 LA61/LK61-Z/31/115 Cost-optimized series for standard tasks in a special design Compact design Wide range of mounting options thanks to cubic housing design with M30 thread 360° high visibility LEDs Programmable ON-delay, OFF-delay, and One-shot timers Version for universal voltages Relay output

شبكات MPN 911621, PEP911621, LA61/115
رمز النظام المنسق 85365000
Weight 0.24 kg

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

متوفرة عند الطلب

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

معلومات المنتج

وصف

Datasheet excerpt: Technical data of  LA61/LK61-Z/31/115 Product Description Thru-beam sensor System components EmitterLA61/115 ReceiverLK61-Z/31/115 General specifications Effective detection range0 ... 60 m Threshold detection range85 m Light sourceIRED Light typemodulated infrared light , 850 nm Diameter of the light spot1600 mm at a distance of 60 m Opening angleEmitter: 1.5 ° , Receiver: 1.5 ° Optical facefrontal Ambient light limit5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator2 LEDs green Function indicator2 LEDs yellow Receiver: receiver LED yellow, lights up when light beam is free, flashes when falling short of the stability control ; OFF when light beam is interrupted Control elementsLight-on/dark-on changeover switch Control elementsSensing range adjuster Control elementsTime adjuster ( 0 ... 10 s ) Electrical specifications Operating voltage24 ... 240 V AC 12 ... 240 V DC No-load supply current≤ 35 mA Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption≤ 2 VA per device Output Switching typelight/dark on, switchable Signal output1 SPDT relay Switching voltagemax. 250 V AC/DC Switching currentmax. 3 A Switching powerDC: max. 150 W AC: max. 750 VA Switching frequency20 Hz Response time≤ 25 ms Timer functionDIP-switch for selection of operating modes Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 Standard conformity Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007 StandardsEN 50178, UL 508 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 UL approvalcULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 55 °C (-40 ... 131 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width45 mm Housing height73.7 mm Housing depth48.6 mm Degree of protectionIP67 Connection2 m fixed cable Material HousingPC (glass-fiber-reinforced Makrolon) Optical facePMMA Mass240 g per device Tightening torque, fastening screws< 2 Nm Cable length2 m Classifications SystemClasscode ECLASS 11.027270901 ECLASS 10.0.127270901 ECLASS 9.027270901 ECLASS 8.027270901 ECLASS 5.127270901 ETIM 8.0EC002716 ETIM 7.0EC002716 ETIM 6.0EC002716 ETIM 5.0EC002716 UNSPSC 12.139121528 Datasheet excerpt: Technical data of  LA61/LK61-Z/31/115 Product Description Thru-beam sensor System components EmitterLA61/115 ReceiverLK61-Z/31/115 General specifications Effective detection range0 ... 60 m Threshold detection range85 m Light sourceIRED Light typemodulated infrared light , 850 nm Diameter of the light spot1600 mm at a distance of 60 m Opening angleEmitter: 1.5 ° , Receiver: 1.5 ° Optical facefrontal Ambient light limit5000 Lux ; according EN 60947-5-2 Indicators/operating means Operation indicator2 LEDs green Function indicator2 LEDs yellow Receiver: receiver LED yellow, lights up when light beam is free, flashes when falling short of the stability control ; OFF when light beam is interrupted Control elementsLight-on/dark-on changeover switch Control elementsSensing range adjuster Control elementsTime adjuster ( 0 ... 10 s ) Electrical specifications Operating voltage24 ... 240 V AC 12 ... 240 V DC No-load supply current≤ 35 mA Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC Power consumption≤ 2 VA per device Output Switching typelight/dark on, switchable Signal output1 SPDT relay Switching voltagemax. 250 V AC/DC Switching currentmax. 3 A Switching powerDC: max. 150 W AC: max. 750 VA Switching frequency20 Hz Response time≤ 25 ms Timer functionDIP-switch for selection of operating modes Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 Standard conformity Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007 StandardsEN 50178, UL 508 Approvals and certificates EAC conformityTR CU 020/2011 TR CU 004/2011 UL approvalcULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC/DC CCC approvalCertified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature-40 ... 55 °C (-40 ... 131 °F) Storage temperature-40 ... 70 °C (-40 ... 158 °F) Mechanical specifications Housing width45 mm Housing height73.7 mm Housing depth48.6 mm Degree of protectionIP67 Connection2 m fixed cable Material HousingPC (glass-fiber-reinforced Makrolon) Optical facePMMA Mass240 g per device Tightening torque, fastening screws< 2 Nm Cable length2 m Classifications SystemClasscode ECLASS 11.027270901 ECLASS 10.0.127270901 ECLASS 9.027270901 ECLASS 8.027270901 ECLASS 5.127270901 ETIM 8.0EC002716 ETIM 7.0EC002716 ETIM 6.0EC002716 ETIM 5.0EC002716 UNSPSC 12.139121528

مراجعات شركتنا