NCB20-L2-N0-V1 PEPPERL+FUCHS - Part number: 70133147

PEPPERL+FUCHS

Inductive sensor NCB20-L2-N0-V1 NCB20-L2-N0-V1 Sensor head bidirectional and rotatable 20 mm flush Quick mounting bracket Usable up to SIL 2 acc. to IEC 61508 NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers Inductive sensor NCB20-L2-N0-V1 NCB20-L2-N0-V1 Sensor head bidirectional and rotatable 20 mm flush Quick mounting bracket Usable up to SIL 2 acc. to IEC 61508 NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below: Go to our Switch Amplifiers

شبكات MPN 70133147, PEP70133147, NCB20-L2-N0-V1
رمز النظام المنسق 85365090
Weight 0.13 kg

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.

المنتج متوفر بعدة حالات

غير متوفر حالياً

حالة بديلة

102.54 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
نحن شريك متخصص لـ PEPPERL+FUCHS
To الولايات المتحدة الأمريكية starting from 27.36 USD بواسطة DHL Express Worldwide
اطلب عرض أسعار لمعرفة تاريخ التسليم

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

2 متاح من الشركاء السعر والتسليم بناء على طلب الاقتباس
عليك التسجيل

معلومات المنتج

وصف

Datasheet excerpt: Technical data of  NCB20-L2-N0-V1 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance20 mm Installationflush Assured operating distance0 ... 16.2 mm Actual operating distance18 ... 22 mm Reduction factor rAl 0.33 Reduction factor rCu 0.31 Reduction factor r304 0.74 Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 300 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Current consumption Measuring plate not detected≥ 2.2 mA Measuring plate detected≤ 1 mA Switching state indicatorLED, yellow Functional safety related parameters Safety Integrity Level (SIL)SIL 2 MTTFd1660 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X Equipment protection level Dc (tc)IECEx TUR 21.0020X Equipment protection level MbIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X Equipment protection level Dc (tc)TÜV 20 ATEX 8526 X EAC conformityTR CU 012/2011 Protection classII Rated insulation voltage253 V Rated impulse withstand voltage4000 V UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002302 NEPSI approval NEPSI certificateGYJ16.1394X ANZEx19.3001X Marine approvalDNVGL TAA00001A5 Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typeConnector plug Housing materialPA Sensing facePA Degree of protectionIP66 / IP69K Connector ThreadingM12 x 1 Number of pins4 Mass130 g General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550 Datasheet excerpt: Technical data of  NCB20-L2-N0-V1 General specifications Switching functionNormally closed (NC) Output typeNAMUR Rated operating distance20 mm Installationflush Assured operating distance0 ... 16.2 mm Actual operating distance18 ... 22 mm Reduction factor rAl 0.33 Reduction factor rCu 0.31 Reduction factor r304 0.74 Nominal ratings Nominal voltage8.2 V (Ri 1 kΩ) Switching frequency0 ... 300 Hz Hysteresistyp. 5 % Reverse polarity protectionreverse polarity protected Short-circuit protectionyes Current consumption Measuring plate not detected≥ 2.2 mA Measuring plate detected≤ 1 mA Switching state indicatorLED, yellow Functional safety related parameters Safety Integrity Level (SIL)SIL 2 MTTFd1660 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Compliance with standards and directives Standard conformity NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999 StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates IECEx approval Equipment protection level GaIECEx PTB 11.0021X Equipment protection level GbIECEx PTB 11.0021X Equipment protection level DaIECEx PTB 11.0021X Equipment protection level Dc (tc)IECEx TUR 21.0020X Equipment protection level MbIECEx PTB 11.0021X ATEX approval Equipment protection level GaPTB 00 ATEX 2032 X Equipment protection level GbPTB 00 ATEX 2032 X Equipment protection level DaPTB 00 ATEX 2032 X Equipment protection level Dc (tc)TÜV 20 ATEX 8526 X EAC conformityTR CU 012/2011 Protection classII Rated insulation voltage253 V Rated impulse withstand voltage4000 V UL approval Ordinary LocationE87056 Hazardous LocationE501628 Control drawing116-0451 CCC approval Hazardous Location2020322315002302 NEPSI approval NEPSI certificateGYJ16.1394X ANZEx19.3001X Marine approvalDNVGL TAA00001A5 Ambient conditions Ambient temperature-25 ... 100 °C (-13 ... 212 °F) Storage temperature-40 ... 100 °C (-40 ... 212 °F) Mechanical specifications Connection typeConnector plug Housing materialPA Sensing facePA Degree of protectionIP66 / IP69K Connector ThreadingM12 x 1 Number of pins4 Mass130 g General information Use in the hazardous areasee instruction manuals Classifications SystemClasscode ECLASS 11.027270101 ECLASS 10.0.127270101 ECLASS 9.027270101 ECLASS 8.027270101 ECLASS 5.127270101 ETIM 8.0EC002714 ETIM 7.0EC002714 ETIM 6.0EC002714 ETIM 5.0EC002714 UNSPSC 12.139121550

مراجعات شركتنا