KFU8-DW-1.D PEPPERL+FUCHS - Part number: 190149
غير متوفر - طلب متأخر
لطلب من الشركة المصنعة
619.71 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل

KFU8-DW-1.D PEPPERL+FUCHS - Part number: 190149

PEPPERL+FUCHS

Rotation Speed Monitor KFU8-DW-1.D KFU8-DW-1.D Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec. Rotation Speed Monitor KFU8-DW-1.D KFU8-DW-1.D Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec.

شبكات MPN 190149, PEP190149, KFU8-DW-1.D
Weight N/A

صورة المنتج هي لأغراض توضيحية فقط.
يتم توفير بلد المنشأ ورمز النظام المنسق والوصف من قبل الشركة المصنعة وقد تكون عرضة للتغيير دون إشعار مسبق. ولهذا السبب، لا يمكن تحميل شركة PLC-City المسؤولية عن أي اختلافات.
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

619.71 USD

ضرائب الاستيراد غير مشمولة

عليك التسجيل
تم بيعه بواسطة PLC-CITY® وتم شحنه من إيطاليا
نحن شريك متخصص لـ PEPPERL+FUCHS
شحن سريع مجاني إلى الولايات المتحدة الأمريكية
Loader...
عرض جميع خدمات الشحن
اطلب عرض أسعار لمعرفة تاريخ التسليم

نحن نقبل العديد من طرق الدفع: التحويل البنكي (SEPA، ACH)، بطاقات الخصم/الائتمان (Mastercard، VISA، American Express، Diners Club، Discover، JCB، UnionPay)، PayPal، ApplePay، GooglePay، link by Stripe، Cartes Bancaires، Alipay، Bancontact، blik، eps، giropay iDeal، Przelewy24، WeChatPay.
مزيد من المعلومات حول طرق الدفع لدينا

هذا المنتج مشمول بضمان 12 شهور، صالح لعيوب التصنيع أو الأعطال. لا يغطي الضمان الأضرار الناجمة عن الاستخدام غير السليم أو الأضرار العرضية.
تعرف على المزيد حول الضمان الخاص بنا

يُشترط الحصول على موافقة مسبقة لإجراء الإرجاع، ويتم إصدار رصيد بدلاً من استرداد نقدي. الطلبات المسبقة (Backorder) غير مشمولة.

اطلع على سياسة الإرجاع الخاصة بنا

احصل على عرض الأسعار الشخصي الخاص بك الآن

سيساعدك مندوب المبيعات المخصص على تقديم أفضل الأسعار وأوقات التسليم.

عليك التسجيل

اطلب الخدمة الفنية المخصصة لك

اعتمد على فريقنا الفني الخبير للحصول على مجموعة من الخدمات الشخصية: الإصلاح والبرمجة والصيانة وغير ذلك الكثير.

معلومات المنتج

وصف

Datasheet excerpt: Technical data of  KFU8-DW-1.D Product Description Rotation Speed Monitor Functional safety related parameters MTTFd100 a Supply Rated voltage200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 20 VDC ... 30 VDC Fusingexternal fusing 4 A Power consumptionAC: < 5 VADC: < 5 W Input 1 Connectionterminals 8-, 9+ Connectable sensor typesNAMUR sensors according to DIN EN 60947-5-6 Open loop voltage8.2 V DC Short-circuit current6.5 mA Switching point1.2 ... 2.1 mA Switching hysteresis 0.2 mA Input frequency0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs Impedance1.2 kΩ Input 2 Switching pointhigh: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩlow: 0 ... 6 V DC Input frequency0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs Connectionterminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) Connectable sensor typesTwo, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V Sensor supply19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected Input 3 Start-up overrideTriggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged) Jumpering time0.1 ... 999.9 s (External trigger signal) Output Relay1 changeover contact NO, NC, COM Sensor supply24 V DC ± 10 %, 30 mA , short-circuit protected Contact loading250 V AC/2 A/ cos φ ≥ 0.740 V DC/2 A Delay≤ 20 ms (incl. calculation time) Mechanical life≥ 30.000.000 switching cycles Transfer characteristics Changing interval5 ms (Internal processing time) Time delay before availability≤ 400 ms Measuring error0 ... 40000 Hz: ≤ ±0,10% Display: ±1 digit Timer functionON-delay, OFF-delay, one shot, pulse extension Time0 ... 999.9 s ; mode of operation reversible Standard conformity Electromagnetic compatibilityacc. to EN 50081-2 / EN 50082-2 Ambient conditions Ambient temperature-25 ... 40 °C (-13 ... 104 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humiditymax. 80 %, not condensing Altitude0 ... 2000 m Operating conditionsThe device has only to be used in an indoor area. Mechanical specifications Connection assemblyCaution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. Degree of protectionIP20 Connectioncoded, removable terminals , max. core cross section 0.34 ... 2.5 mm2 Construction typemodular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module Mountingsnap-on to 35 mm standard rail or screw fixing Classifications SystemClasscode ECLASS 11.027210904 ECLASS 10.0.127210904 ECLASS 9.027210904 ECLASS 8.027210904 ECLASS 5.127210904 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007 Datasheet excerpt: Technical data of  KFU8-DW-1.D Product Description Rotation Speed Monitor Functional safety related parameters MTTFd100 a Supply Rated voltage200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 20 VDC ... 30 VDC Fusingexternal fusing 4 A Power consumptionAC: < 5 VADC: < 5 W Input 1 Connectionterminals 8-, 9+ Connectable sensor typesNAMUR sensors according to DIN EN 60947-5-6 Open loop voltage8.2 V DC Short-circuit current6.5 mA Switching point1.2 ... 2.1 mA Switching hysteresis 0.2 mA Input frequency0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs Impedance1.2 kΩ Input 2 Switching pointhigh: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩlow: 0 ... 6 V DC Input frequency0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs Connectionterminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) Connectable sensor typesTwo, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V Sensor supply19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected Input 3 Start-up overrideTriggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged) Jumpering time0.1 ... 999.9 s (External trigger signal) Output Relay1 changeover contact NO, NC, COM Sensor supply24 V DC ± 10 %, 30 mA , short-circuit protected Contact loading250 V AC/2 A/ cos φ ≥ 0.740 V DC/2 A Delay≤ 20 ms (incl. calculation time) Mechanical life≥ 30.000.000 switching cycles Transfer characteristics Changing interval5 ms (Internal processing time) Time delay before availability≤ 400 ms Measuring error0 ... 40000 Hz: ≤ ±0,10% Display: ±1 digit Timer functionON-delay, OFF-delay, one shot, pulse extension Time0 ... 999.9 s ; mode of operation reversible Standard conformity Electromagnetic compatibilityacc. to EN 50081-2 / EN 50082-2 Ambient conditions Ambient temperature-25 ... 40 °C (-13 ... 104 °F) Storage temperature-40 ... 85 °C (-40 ... 185 °F) Relative humiditymax. 80 %, not condensing Altitude0 ... 2000 m Operating conditionsThe device has only to be used in an indoor area. Mechanical specifications Connection assemblyCaution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. Degree of protectionIP20 Connectioncoded, removable terminals , max. core cross section 0.34 ... 2.5 mm2 Construction typemodular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module Mountingsnap-on to 35 mm standard rail or screw fixing Classifications SystemClasscode ECLASS 11.027210904 ECLASS 10.0.127210904 ECLASS 9.027210904 ECLASS 8.027210904 ECLASS 5.127210904 ETIM 8.0EC002918 ETIM 7.0EC002918 ETIM 6.0EC002918 ETIM 5.0EC002475 UNSPSC 12.139121007