SM2X1202 - Lovato - Accessory for SM2/SM3 motor protection
Out of Stock - Backorder
To order from manufacturer
Minimum order quantity - 2
USD11.36

Import Taxes Excluded

Minimum order quantity - 2

Need a smaller quantity? Contact us!

You must be logged

SM2X1202 - Lovato - Accessory for SM2/SM3 motor protection

Lovato

Additional auxiliary contact, side mounting, 2 NC, for SM2 and SM3 series Additional auxiliary contact, side mounting, 2 NC, for SM2 and SM3 series

MPNs SM2X1202, LOVSM2X1202
EAN 8013975219942
HS Code 85362010
Country of origin South Korea
Weight 0.05 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD11.36

Import Taxes Excluded

Minimum order quantity - 2

Need a smaller quantity? Contact us!

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of Lovato
To United States starting from USD27.36 by DHL Express Worldwide
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

<h3>Auxiliary contact block for status signalling</h3><p>This component adds auxiliary status or command contacts to a compatible protection device. It transfers open, closed or trip-related information to the control circuit without changing the power path.</p><h4>Main technical data</h4><p>contact arrangement 2 NC.</p><h4>Panel use and installation</h4><p>In the electrical panel, the product should be matched with the compatible device family, the wiring diagram and the function assigned to the circuit. Correct selection keeps protection, command, signalling and power distribution functions easy to identify during commissioning and service.</p><ul><li>Use in automation cabinets, machine controls and motor starter groups.</li><li>Check voltage, contact arrangement, release function or connection type before wiring.</li><li>Separate power wiring, control wiring and signalling paths inside the panel.</li><li>Mark the connected circuit and test the function after installation.</li></ul><p>During commissioning, verify terminal tightening, mechanical engagement and response of the connected circuit. In maintenance, identify the accessory type together with the electrical data so the replacement preserves the same function in the assembly. The final check should include the operating sequence, the condition of the control wiring and the correspondence between the panel marking and the connected circuit.</p><p>When the component is used as a spare part, compare the circuit function before removal, the electrical data on the existing device and the position in the assembly. This check is especially important in starter panels where protection, command and signalling devices are mounted close together but perform different tasks. The check should be carried out with the panel de-energized and with reference to the machine functional diagram.</p> <h3>Auxiliary contact block for status signalling</h3><p>This component adds auxiliary status or command contacts to a compatible protection device. It transfers open, closed or trip-related information to the control circuit without changing the power path.</p><h4>Main technical data</h4><p>contact arrangement 2 NC.</p><h4>Panel use and installation</h4><p>In the electrical panel, the product should be matched with the compatible device family, the wiring diagram and the function assigned to the circuit. Correct selection keeps protection, command, signalling and power distribution functions easy to identify during commissioning and service.</p><ul><li>Use in automation cabinets, machine controls and motor starter groups.</li><li>Check voltage, contact arrangement, release function or connection type before wiring.</li><li>Separate power wiring, control wiring and signalling paths inside the panel.</li><li>Mark the connected circuit and test the function after installation.</li></ul><p>During commissioning, verify terminal tightening, mechanical engagement and response of the connected circuit. In maintenance, identify the accessory type together with the electrical data so the replacement preserves the same function in the assembly. The final check should include the operating sequence, the condition of the control wiring and the correspondence between the panel marking and the connected circuit.</p><p>When the component is used as a spare part, compare the circuit function before removal, the electrical data on the existing device and the position in the assembly. This check is especially important in starter panels where protection, command and signalling devices are mounted close together but perform different tasks. The check should be carried out with the panel de-energized and with reference to the machine functional diagram.</p>

Technical specifications

Mounting method
Side mounting
Model
Integrable
Number of contacts as normally closed contact
2
Type of electric connection
Screw connection
Rated operation current Ie at AC-15, 230 V
3 A