SA2DFK00M2 - Lovato - Surge protection device
Lovato
surge protective device, for photovoltaic applications, type 2, plug-in cartridge, short-circuit current Iscpv 1000 A, +, -, PE, 1000 VDC, without remote contact. surge protective device, for photovoltaic applications, type 2, plug-in cartridge, short-circuit current Iscpv 1000 A, +, -, PE, 1000 VDC, without remote contact.
MPNs SA2DFK00M2, LOVSA2DFK00M2
EAN 8013975210369
HS Code 85365080
Country of origin Slovenia
Weight
0.28 kg
The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy
Secure payments
& many more
We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods
12 Months warranty
This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty
Returns available within 30 days
Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.
Product information
Description
<h3>Surge protective device for electrical panels</h3><p>This surge protection component limits transient overvoltages in electrical panels and protects downstream equipment from surge events. It is used in machine control, distribution and photovoltaic circuits when specified, where surge current must be diverted through a coordinated protective path.</p><h4>Surge data and circuit coordination</h4><p>component type surge protective device; SPD type type 2; voltage 1000 VDC; remote contact without remote contact; application photovoltaic. Selection must follow SPD type, discharge current values, pole arrangement, voltage level and the presence of any remote signalling contact. Plug-in cartridges must match the base series and the protected circuit so that maintenance can restore the same protective function.</p><h4>Inspection and replacement</h4><p>During service, check the indicator or remote signal, compare cartridge data with the installed base and verify the connection to the protective conductor path. After replacement, restore markings and repeat the visual inspection before returning the panel to operation.</p><p>The panel record should identify the protected line, earthing path and any remote signal used by the monitoring system. When a cartridge is replaced, keep the same surge type, current rating and voltage level, then check the indicator state before closing the panel.</p><p>Correct coordination also makes routine inspection easier: the operator can read the local indication, compare it with the remote alarm when present and immediately understand whether the protective path is still ready to divert the next transient surge.</p><p>For mixed distribution and automation panels, consistent labelling of the protected feeder helps maintenance teams distinguish power supply, control and photovoltaic lines during inspection.</p>
<h3>Surge protective device for electrical panels</h3><p>This surge protection component limits transient overvoltages in electrical panels and protects downstream equipment from surge events. It is used in machine control, distribution and photovoltaic circuits when specified, where surge current must be diverted through a coordinated protective path.</p><h4>Surge data and circuit coordination</h4><p>component type surge protective device; SPD type type 2; voltage 1000 VDC; remote contact without remote contact; application photovoltaic. Selection must follow SPD type, discharge current values, pole arrangement, voltage level and the presence of any remote signalling contact. Plug-in cartridges must match the base series and the protected circuit so that maintenance can restore the same protective function.</p><h4>Inspection and replacement</h4><p>During service, check the indicator or remote signal, compare cartridge data with the installed base and verify the connection to the protective conductor path. After replacement, restore markings and repeat the visual inspection before returning the panel to operation.</p><p>The panel record should identify the protected line, earthing path and any remote signal used by the monitoring system. When a cartridge is replaced, keep the same surge type, current rating and voltage level, then check the indicator state before closing the panel.</p><p>Correct coordination also makes routine inspection easier: the operator can read the local indication, compare it with the remote alarm when present and immediately understand whether the protective path is still ready to divert the next transient surge.</p><p>For mixed distribution and automation panels, consistent labelling of the protected feeder helps maintenance teams distinguish power supply, control and photovoltaic lines during inspection.</p>
Technical specifications
- Degree of protection (IP)
- IP20
- Mounting method
- DIN rail (top hat rail) 35 mm
- Nominal voltage DC
- 1100 V
- Number of conductors (without earthing)
- 2
- Nominal discharge surge current (8/20)
- 20 kA
- Category type 2
- TRUE
- Max. conductor cross section solid (solid, stranded)
- 35 mm²
- Max. conductor cross section flexible (fine-strand)
- 25 mm²
- System configuration DC
- TRUE
- Max. continuous voltage AC
- 320 V
- Construction size
- 3 modular spacing
- Signalling at the device