BF0004A400 - Lovato - BF/B contactor
Out of Stock - Backorder
To order from manufacturer
USD32.98

Import Taxes Excluded

You must be logged

BF0004A400 - Lovato - BF/B contactor

Lovato

Control relay with AC coil, 400 VAC 50/60 Hz, 4 NC Control relay with AC coil, 400 VAC 50/60 Hz, 4 NC

MPNs BF0004A400, LOVBF0004A400
EAN 8013975162934
HS Code 85365080
Country of origin Italy
Weight 0.37 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

This product can only be returned in case of defects covered by the warranty.

View our return policy

USD32.98

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of Lovato
To United States starting from USD27.36 by DHL Express Worldwide
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

This product can only be returned in case of defects covered by the warranty.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

<h3>Auxiliary control relay for command circuits</h3><p>This component switches auxiliary command circuits in machines and automation panels. It is used for interlocking, permissive signals, control logic and status transmission where multiple control contacts are required.</p><h4>Main technical data</h4><p>The technical configuration of this family includes 4 poles, Ui 690 V, Uimp 6 kV, Ith 10 A at 40°C, operating frequency 25-400 Hz and gG fuse protection 16 A; control voltage 460 VAC 60 Hz; contact arrangement 4 NC.</p><h4>Panel use and installation</h4><p>In the electrical panel, the product should be matched with the compatible device family, the wiring diagram and the function assigned to the circuit. Correct selection keeps protection, command, signalling and power distribution functions easy to identify during commissioning and service.</p><ul><li>Use in automation cabinets, machine controls and motor starter groups.</li><li>Check voltage, contact arrangement, release function or connection type before wiring.</li><li>Separate power wiring, control wiring and signalling paths inside the panel.</li><li>Mark the connected circuit and test the function after installation.</li></ul><p>During commissioning, verify terminal tightening, mechanical engagement and response of the connected circuit. In maintenance, identify the accessory type together with the electrical data so the replacement preserves the same function in the assembly. The final check should include the operating sequence, the condition of the control wiring and the correspondence between the panel marking and the connected circuit.</p><p>When the component is used as a spare part, compare the circuit function before removal, the electrical data on the existing device and the position in the assembly. This check is especially important in starter panels where protection, command and signalling devices are mounted close together but perform different tasks. The check should be carried out with the panel de-energized and with reference to the machine functional diagram.</p> <h3>Auxiliary control relay for command circuits</h3><p>This component switches auxiliary command circuits in machines and automation panels. It is used for interlocking, permissive signals, control logic and status transmission where multiple control contacts are required.</p><h4>Main technical data</h4><p>The technical configuration of this family includes 4 poles, Ui 690 V, Uimp 6 kV, Ith 10 A at 40°C, operating frequency 25-400 Hz and gG fuse protection 16 A; control voltage 460 VAC 60 Hz; contact arrangement 4 NC.</p><h4>Panel use and installation</h4><p>In the electrical panel, the product should be matched with the compatible device family, the wiring diagram and the function assigned to the circuit. Correct selection keeps protection, command, signalling and power distribution functions easy to identify during commissioning and service.</p><ul><li>Use in automation cabinets, machine controls and motor starter groups.</li><li>Check voltage, contact arrangement, release function or connection type before wiring.</li><li>Separate power wiring, control wiring and signalling paths inside the panel.</li><li>Mark the connected circuit and test the function after installation.</li></ul><p>During commissioning, verify terminal tightening, mechanical engagement and response of the connected circuit. In maintenance, identify the accessory type together with the electrical data so the replacement preserves the same function in the assembly. The final check should include the operating sequence, the condition of the control wiring and the correspondence between the panel marking and the connected circuit.</p><p>When the component is used as a spare part, compare the circuit function before removal, the electrical data on the existing device and the position in the assembly. This check is especially important in starter panels where protection, command and signalling devices are mounted close together but perform different tasks. The check should be carried out with the panel de-energized and with reference to the machine functional diagram.</p>

Technical specifications

Mounting method
DIN-rail/screw
Voltage type for actuating
AC
Rated control supply voltage AC 50 Hz
400;400 V
Rated control supply voltage AC 60 Hz
400;400 V
Connection type auxiliary circuit
Screw connection
Rated operation current Ie, 400 V
10 A
Number of auxiliary contacts as normally closed contact
4

Our Company Reviews