3-pole contactor BF26.00, Ie AC-3 26 A, AC coil, 120 VAC 60 Hz 3-pole contactor BF26.00, Ie AC-3 26 A, AC coil, 120 VAC 60 Hz

MPNs BF2600A12060, LOVBF2600A12060
EAN 8013975165119
HS Code 85365080
Country of origin Italy
Weight 0.42 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

This product can only be returned in case of defects covered by the warranty.

View our return policy

USD66.39

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of Lovato
To United States starting from USD27.36 by DHL Express Worldwide
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

This product can only be returned in case of defects covered by the warranty.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

<h3>Contactor for motor switching</h3><p>This contactor switches motor loads in machine panels, automation lines and starter assemblies. The coil controls the power contacts, allowing the motor line to be opened and closed from an auxiliary command circuit.</p><h4>Coil, poles and AC-3 rating</h4><p>poles 3; Ie AC-3 26 A; coil voltage 120 VAC 60 Hz. The AC-3 value identifies the motor switching duty and is the main reference when selecting the device for a starter. Pole count defines the power circuit layout, while the coil voltage must match the available control supply in the panel.</p><h4>Starter integration</h4><p>In the starter assembly, the contactor works with the protection device and any signalling accessories. During testing, check start and stop sequence, coil response, terminal tightening and correspondence between wiring diagram and conductor marking.</p><p>For replacement, compare coil voltage, AC-3 current, pole count and auxiliary contact layout before removing the installed unit. This keeps the starter logic unchanged and prevents confusing a power contactor with an auxiliary relay or signalling component. In service, the contactor should be checked together with the upstream protection device and the downstream motor line. The inspection should include contact response, coil energization, conductor marking, auxiliary feedback and the mechanical condition of the terminals. These checks help maintain a clear relationship between the command circuit and the power circuit. Terminal numbering and auxiliary feedback should also be compared with the electrical diagram before the panel is returned to service.</p><p>This approach is useful in maintenance because it links the visible wiring, the command function and the motor switching duty in a single check. It also supports clear identification in panels where several contactors have similar appearance but different coils, auxiliary contacts or AC-3 ratings.</p> <h3>Contactor for motor switching</h3><p>This contactor switches motor loads in machine panels, automation lines and starter assemblies. The coil controls the power contacts, allowing the motor line to be opened and closed from an auxiliary command circuit.</p><h4>Coil, poles and AC-3 rating</h4><p>poles 3; Ie AC-3 26 A; coil voltage 120 VAC 60 Hz. The AC-3 value identifies the motor switching duty and is the main reference when selecting the device for a starter. Pole count defines the power circuit layout, while the coil voltage must match the available control supply in the panel.</p><h4>Starter integration</h4><p>In the starter assembly, the contactor works with the protection device and any signalling accessories. During testing, check start and stop sequence, coil response, terminal tightening and correspondence between wiring diagram and conductor marking.</p><p>For replacement, compare coil voltage, AC-3 current, pole count and auxiliary contact layout before removing the installed unit. This keeps the starter logic unchanged and prevents confusing a power contactor with an auxiliary relay or signalling component. In service, the contactor should be checked together with the upstream protection device and the downstream motor line. The inspection should include contact response, coil energization, conductor marking, auxiliary feedback and the mechanical condition of the terminals. These checks help maintain a clear relationship between the command circuit and the power circuit. Terminal numbering and auxiliary feedback should also be compared with the electrical diagram before the panel is returned to service.</p><p>This approach is useful in maintenance because it links the visible wiring, the command function and the motor switching duty in a single check. It also supports clear identification in panels where several contactors have similar appearance but different coils, auxiliary contacts or AC-3 ratings.</p>

Technical specifications

Voltage type for actuating
AC
Rated control supply voltage AC 60 Hz
120;120 V
Type of electrical connection of main circuit
Screw connection
Rated operation power at AC-3, 400 V
13 kW
Number of normally open contacts as main contact
3
Rated operation current Ie at AC-3, 400 V
26 A
Rated operation current Ie at AC-1, 400 V
45 A
Rated operation current Ie at AC-4, 400 V
11.5 A