SM1X1740P - Lovato - SM1P-R motor protection circuit breaker
USD18.37

Import Taxes Excluded

You must be logged

SM1X1740P - Lovato - SM1P-R motor protection circuit breaker

Lovato

Emergency stop pushbutton, IP65 (4X), for SM1Z P series enclosures Emergency stop pushbutton, IP65 (4X), for SM1Z P series enclosures

MPNs SM1X1740P, LOVSM1X1740P
EAN 8013975219386
HS Code 85381000
Country of origin Italy
Weight 0.06 kg
Volumetric weight 0.07 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD18.37

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of Lovato
To United States starting from USD27.36 by DHL Express Worldwide
Loader...
View all shipping services

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

<h3>Emergency stop pushbutton for protected enclosures</h3><p>This component adds an emergency stop command to a protected enclosure. It gives the operator a clear local interface for stopping a machine or starter group in an abnormal condition.</p><h4>Main technical data</h4><p>IP65 (4X).</p><h4>Panel use and installation</h4><p>In the electrical panel, the product should be matched with the compatible device family, the wiring diagram and the function assigned to the circuit. Correct selection keeps protection, command, signalling and power distribution functions easy to identify during commissioning and service.</p><ul><li>Use in automation cabinets, machine controls and motor starter groups.</li><li>Check voltage, contact arrangement, release function or connection type before wiring.</li><li>Separate power wiring, control wiring and signalling paths inside the panel.</li><li>Mark the connected circuit and test the function after installation.</li></ul><p>During commissioning, verify terminal tightening, mechanical engagement and response of the connected circuit. In maintenance, identify the accessory type together with the electrical data so the replacement preserves the same function in the assembly. The final check should include the operating sequence, the condition of the control wiring and the correspondence between the panel marking and the connected circuit.</p><p>When the component is used as a spare part, compare the circuit function before removal, the electrical data on the existing device and the position in the assembly. This check is especially important in starter panels where protection, command and signalling devices are mounted close together but perform different tasks. The check should be carried out with the panel de-energized and with reference to the machine functional diagram.</p> <h3>Emergency stop pushbutton for protected enclosures</h3><p>This component adds an emergency stop command to a protected enclosure. It gives the operator a clear local interface for stopping a machine or starter group in an abnormal condition.</p><h4>Main technical data</h4><p>IP65 (4X).</p><h4>Panel use and installation</h4><p>In the electrical panel, the product should be matched with the compatible device family, the wiring diagram and the function assigned to the circuit. Correct selection keeps protection, command, signalling and power distribution functions easy to identify during commissioning and service.</p><ul><li>Use in automation cabinets, machine controls and motor starter groups.</li><li>Check voltage, contact arrangement, release function or connection type before wiring.</li><li>Separate power wiring, control wiring and signalling paths inside the panel.</li><li>Mark the connected circuit and test the function after installation.</li></ul><p>During commissioning, verify terminal tightening, mechanical engagement and response of the connected circuit. In maintenance, identify the accessory type together with the electrical data so the replacement preserves the same function in the assembly. The final check should include the operating sequence, the condition of the control wiring and the correspondence between the panel marking and the connected circuit.</p><p>When the component is used as a spare part, compare the circuit function before removal, the electrical data on the existing device and the position in the assembly. This check is especially important in starter panels where protection, command and signalling devices are mounted close together but perform different tasks. The check should be carried out with the panel de-energized and with reference to the machine functional diagram.</p>

Technical specifications

Type of accessory/spare part
Other

Our Company Reviews