Free express shipping to Europe, USA and Canada on web orders over €150 (up to 10kg).
info
Explore
-
MenuBack
-
Brands
-
- Technologies for :
-
Industry
-
-
Building
-
-
Electrification
-
-
Tools
-
- Contact Us
- About Us
- Promo
contact info
-
PLC-City
Via Circumvallazione esterna 12
80025 Casandrino NA
Italy
Menu
RFE450050 - Lovato - Electronic protection relay
Lovato
Electronic overload relay, phase-failure and single-phasing sensitive, 3-pole (three-phase), manual or automatic reset, 0.1-0.5 A Electronic overload relay, phase-failure and single-phasing sensitive, 3-pole (three-phase), manual or automatic reset, 0.1-0.5 A
MPNs RFE450050, LOVRFE450050
EAN 8013975230220
HS Code 85364900
Country of origin China
Weight
0.15 kg
The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy
Secure payments
& many more
We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods
12 Months warranty
This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty
Returns available within 30 days
Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.
Product information
Description
<h3>Motor protection relay for three-phase lines</h3><p>This motor protection relay is designed for three-phase motor circuits where overload protection must be coordinated with monitoring of phase-failure and single-phasing conditions. It is used in control panels for pumps, fans, conveyors and industrial machines where the motor line must be supervised with a dedicated relay.</p><h4>Current setting and phase supervision</h4><p>current range 0.1-0.5 A; 3-pole three-phase execution; phase-failure and single-phasing sensitive; manual or automatic reset. The current range defines the motor load window to be protected and must be matched to the application during panel setup. Sensitivity to phase-failure and single-phasing helps detect operating conditions that can stress a three-phase motor even when the command circuit is still active. The 3-pole construction keeps the relay aligned with the three-phase power path.</p><h4>Reset and maintenance check</h4><p>Manual or automatic reset allows the protection strategy to be adapted to the machine sequence. During replacement or commissioning, compare the current setting, reset mode, wiring position and relay series with the electrical diagram before restarting the motor. After a trip, the cause should be checked on the motor line before the relay is reset.</p><p>For clear panel service, keep the relay setting, motor identification and trip information aligned. This makes troubleshooting faster and helps distinguish overload, phase-loss and wiring issues without adding assumptions outside the data available on the panel.</p><p>When several motors are installed in the same cabinet, a consistent setting record is important. The relay should be associated with the correct motor feeder, upstream protection and contactor group, so that future work can follow the same electrical path without confusing adjacent circuits.</p>
<h3>Motor protection relay for three-phase lines</h3><p>This motor protection relay is designed for three-phase motor circuits where overload protection must be coordinated with monitoring of phase-failure and single-phasing conditions. It is used in control panels for pumps, fans, conveyors and industrial machines where the motor line must be supervised with a dedicated relay.</p><h4>Current setting and phase supervision</h4><p>current range 0.1-0.5 A; 3-pole three-phase execution; phase-failure and single-phasing sensitive; manual or automatic reset. The current range defines the motor load window to be protected and must be matched to the application during panel setup. Sensitivity to phase-failure and single-phasing helps detect operating conditions that can stress a three-phase motor even when the command circuit is still active. The 3-pole construction keeps the relay aligned with the three-phase power path.</p><h4>Reset and maintenance check</h4><p>Manual or automatic reset allows the protection strategy to be adapted to the machine sequence. During replacement or commissioning, compare the current setting, reset mode, wiring position and relay series with the electrical diagram before restarting the motor. After a trip, the cause should be checked on the motor line before the relay is reset.</p><p>For clear panel service, keep the relay setting, motor identification and trip information aligned. This makes troubleshooting faster and helps distinguish overload, phase-loss and wiring issues without adding assumptions outside the data available on the panel.</p><p>When several motors are installed in the same cabinet, a consistent setting record is important. The relay should be associated with the correct motor feeder, upstream protection and contactor group, so that future work can follow the same electrical path without confusing adjacent circuits.</p>