11RFA910 - Lovato - Thermal overload relay
Out of Stock - Backorder
To order from manufacturer
USD45.73

Import Taxes Excluded

You must be logged

11RFA910 - Lovato - Thermal overload relay

Lovato

Motor protection relay, phase-failure and single-phasing sensitive, 3-pole (three-phase), automatic reset, direct mounting on BG06, BG09, BG12 contactors, 6-10 A Motor protection relay, phase-failure and single-phasing sensitive, 3-pole (three-phase), automatic reset, direct mounting on BG06, BG09, BG12 contactors, 6-10 A

MPNs 11RFA910, LOV11RFA910
EAN 8013975020579
HS Code 85364900
Country of origin Italy
Weight 0.12 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

This product can only be returned in case of defects covered by the warranty.

View our return policy

USD45.73

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of Lovato
To United States starting from USD27.36 by DHL Express Worldwide
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

This product can only be returned in case of defects covered by the warranty.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

<h3>Motor protection relay for three-phase lines</h3><p>This motor protection relay is designed for three-phase motor circuits where overload protection must be coordinated with monitoring of phase-failure and single-phasing conditions. It is used in control panels for pumps, fans, conveyors and industrial machines where the motor line must be supervised with a dedicated relay.</p><h4>Current setting and phase supervision</h4><p>current range 6-10 A; 3-pole three-phase execution; phase-failure and single-phasing sensitive; manual or automatic reset. The current range defines the motor load window to be protected and must be matched to the application during panel setup. Sensitivity to phase-failure and single-phasing helps detect operating conditions that can stress a three-phase motor even when the command circuit is still active. The 3-pole construction keeps the relay aligned with the three-phase power path.</p><h4>Reset and maintenance check</h4><p>Manual or automatic reset allows the protection strategy to be adapted to the machine sequence. During replacement or commissioning, compare the current setting, reset mode, wiring position and relay series with the electrical diagram before restarting the motor. After a trip, the cause should be checked on the motor line before the relay is reset.</p><p>For clear panel service, keep the relay setting, motor identification and trip information aligned. This makes troubleshooting faster and helps distinguish overload, phase-loss and wiring issues without adding assumptions outside the data available on the panel.</p><p>When several motors are installed in the same cabinet, a consistent setting record is important. The relay should be associated with the correct motor feeder, upstream protection and contactor group, so that future work can follow the same electrical path without confusing adjacent circuits.</p> <h3>Motor protection relay for three-phase lines</h3><p>This motor protection relay is designed for three-phase motor circuits where overload protection must be coordinated with monitoring of phase-failure and single-phasing conditions. It is used in control panels for pumps, fans, conveyors and industrial machines where the motor line must be supervised with a dedicated relay.</p><h4>Current setting and phase supervision</h4><p>current range 6-10 A; 3-pole three-phase execution; phase-failure and single-phasing sensitive; manual or automatic reset. The current range defines the motor load window to be protected and must be matched to the application during panel setup. Sensitivity to phase-failure and single-phasing helps detect operating conditions that can stress a three-phase motor even when the command circuit is still active. The 3-pole construction keeps the relay aligned with the three-phase power path.</p><h4>Reset and maintenance check</h4><p>Manual or automatic reset allows the protection strategy to be adapted to the machine sequence. During replacement or commissioning, compare the current setting, reset mode, wiring position and relay series with the electrical diagram before restarting the motor. After a trip, the cause should be checked on the motor line before the relay is reset.</p><p>For clear panel service, keep the relay setting, motor identification and trip information aligned. This makes troubleshooting faster and helps distinguish overload, phase-loss and wiring issues without adding assumptions outside the data available on the panel.</p><p>When several motors are installed in the same cabinet, a consistent setting record is important. The relay should be associated with the correct motor feeder, upstream protection and contactor group, so that future work can follow the same electrical path without confusing adjacent circuits.</p>

Technical specifications

Mounting method
Direct attachment
Max. rated operation voltage Ue
690 V
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
1
Release class
CLASS 10 A
Adjustable current range
6;10 A
Reset function automatic
TRUE