VAN-115/230AC-K27 PEPPERL+FUCHS - Part number: 238626
Out of Stock - Backorder
To order from manufacturer
USD496.84

Import Taxes Excluded

You must be logged

VAN-115/230AC-K27 PEPPERL+FUCHS - Part number: 238626

PEPPERL+FUCHS

AS-Interface power supply VAN-115/230AC-K27 VAN-115/230AC-K27 Up to 4 A output load LED operating display 100 V AC up to 240 V AC AS-Interface filter integrated Earth fault detection AS-Interface power supply VAN-115/230AC-K27 VAN-115/230AC-K27 Up to 4 A output load LED operating display 100 V AC up to 240 V AC AS-Interface filter integrated Earth fault detection

MPNs 238626, PEP238626, VAN-115/230AC-K27
HS Code 85044000
Weight 0.65 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD496.84

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Request your tailored technical service

Rely on our expert technical team for a range of personalized services: repair, programming, maintenance, and much more.

Product information

Description

Datasheet excerpt: Technical data of  VAN-115/230AC-K27 Product Description AS-Interface power supply, data decoupling, 4 A General specifications UL File NumberE223176 MTBF100 a Indicators/operating means Reset push-button switchearth fault simulation/reset of earth fault display LED EFDearth fault display; LED red LED AS-i okLED green:ON: AS-Interface voltage OKOFF: overload or no supply voltage Electrical specifications FusingT3A 15/250 V HBC (not accessible) Rated operating voltage85 … 132 VAC184 … 264 VAC 240 … 300 VDC Rated operating current2.7 A at 115 VAC1.3 A at 230 VAC Supply frequency47 ... 63 Hz (alternatively, DC possible) Efficiencytyp. 90 % (230 VAC, 4 A) Galvanic isolationSELV/PELV Peak inrush current< 3.7 A2s (120 VAC)< 4.6 A2s (132 VAC)< 2.5 A2s (230 VAC)< 3.3 A2s (264 VAC) Output Short-circuit protection/overload> 4,2 A< 6.5 A Current limitstarts at > 4.2 A Voltage30.5 VDC ±3 % fixed Current4 A Residual ripple< 50 mVSS (500 kHz bandwidth, 50 Ω measurement, with resistive load) Overvoltage protectedlimited to max. 55 V Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 55022:2006, EN 55011:2009 Class BEN 61000-6-3:2001 , EN 61204-3:2001 Standard conformity Noise immunityEN 61000-6-2:2005 Emitted interferenceEN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009 Galvanic isolationIEC 60364-4-41:2005 (PELV)IEC 60950:1999 (SELV) Degree of protectionIEC 60529:2001 Pollution degreeEN 50178:1997 Mech. capacityEN 60068-2-6:2008 (Sinus) EN 60068-2-64:2009 (Random) Shock and impact resistanceEN 60068-2-27:1995 Ambient conditions Ambient temperature-10 ... 70 °C (14 ... 158 °F) Note derating Storage temperature-25 ... 85 °C (-13 ... 185 °F) Shock and impact resistance15g/6 ms10g/11 ms Vibration resistanceSine 2 - 17.8 Hz: ± 1.6 mm Sine 17.8 ... 500 Hz : 2 g Random 2 … 500 Hz: 0.5 m2 (s³) Pollution degree2 Mechanical specifications Degree of protectionIP20 Protection class1 (IEC 60536); Protective conductor connection necessary ConnectionConnection terminals, max. conductor cross-section Flexible cable: 0.5 … 4 mm2Rigid cable: 0.5 … 6 mm2Stripping length 7 mm Mass650 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027040301 ECLASS 10.0.127040301 ECLASS 9.027040301 ECLASS 8.027040301 ECLASS 5.127040301 ETIM 8.0EC002540 ETIM 7.0EC002540 ETIM 6.0EC002540 ETIM 5.0EC002540 UNSPSC 12.139121004 Datasheet excerpt: Technical data of  VAN-115/230AC-K27 Product Description AS-Interface power supply, data decoupling, 4 A General specifications UL File NumberE223176 MTBF100 a Indicators/operating means Reset push-button switchearth fault simulation/reset of earth fault display LED EFDearth fault display; LED red LED AS-i okLED green:ON: AS-Interface voltage OKOFF: overload or no supply voltage Electrical specifications FusingT3A 15/250 V HBC (not accessible) Rated operating voltage85 … 132 VAC184 … 264 VAC 240 … 300 VDC Rated operating current2.7 A at 115 VAC1.3 A at 230 VAC Supply frequency47 ... 63 Hz (alternatively, DC possible) Efficiencytyp. 90 % (230 VAC, 4 A) Galvanic isolationSELV/PELV Peak inrush current< 3.7 A2s (120 VAC)< 4.6 A2s (132 VAC)< 2.5 A2s (230 VAC)< 3.3 A2s (264 VAC) Output Short-circuit protection/overload> 4,2 A< 6.5 A Current limitstarts at > 4.2 A Voltage30.5 VDC ±3 % fixed Current4 A Residual ripple< 50 mVSS (500 kHz bandwidth, 50 Ω measurement, with resistive load) Overvoltage protectedlimited to max. 55 V Compliance with standards and directives Directive conformity EMC Directive 2004/108/ECEN 55022:2006, EN 55011:2009 Class BEN 61000-6-3:2001 , EN 61204-3:2001 Standard conformity Noise immunityEN 61000-6-2:2005 Emitted interferenceEN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009 Galvanic isolationIEC 60364-4-41:2005 (PELV)IEC 60950:1999 (SELV) Degree of protectionIEC 60529:2001 Pollution degreeEN 50178:1997 Mech. capacityEN 60068-2-6:2008 (Sinus) EN 60068-2-64:2009 (Random) Shock and impact resistanceEN 60068-2-27:1995 Ambient conditions Ambient temperature-10 ... 70 °C (14 ... 158 °F) Note derating Storage temperature-25 ... 85 °C (-13 ... 185 °F) Shock and impact resistance15g/6 ms10g/11 ms Vibration resistanceSine 2 - 17.8 Hz: ± 1.6 mm Sine 17.8 ... 500 Hz : 2 g Random 2 … 500 Hz: 0.5 m2 (s³) Pollution degree2 Mechanical specifications Degree of protectionIP20 Protection class1 (IEC 60536); Protective conductor connection necessary ConnectionConnection terminals, max. conductor cross-section Flexible cable: 0.5 … 4 mm2Rigid cable: 0.5 … 6 mm2Stripping length 7 mm Mass650 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027040301 ECLASS 10.0.127040301 ECLASS 9.027040301 ECLASS 8.027040301 ECLASS 5.127040301 ETIM 8.0EC002540 ETIM 7.0EC002540 ETIM 6.0EC002540 ETIM 5.0EC002540 UNSPSC 12.139121004

Our Company Reviews