VAA-4E4A-G2-ZA/EA2 PEPPERL+FUCHS - Part number: 188848
Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

VAA-4E4A-G2-ZA/EA2 PEPPERL+FUCHS - Part number: 188848

PEPPERL+FUCHS

AS-Interface sensor/actuator module VAA-4E4A-G2-ZA/EA2 VAA-4E4A-G2-ZA/EA2 AS-Interface certificate Degree of protection IP67 Addressing jack Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring Inputs for 2-, 3-, and 4-wire sensors Power supply of outputs from the external auxiliary voltage Supply for inputs from AS-Interface Ground connection (FE) possible Function display for bus, ext. auxiliary voltage, inputs and outputs Detection of overload on sensor supply Detection of output overload AS-Interface sensor/actuator module VAA-4E4A-G2-ZA/EA2 VAA-4E4A-G2-ZA/EA2 AS-Interface certificate Degree of protection IP67 Addressing jack Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring Inputs for 2-, 3-, and 4-wire sensors Power supply of outputs from the external auxiliary voltage Supply for inputs from AS-Interface Ground connection (FE) possible Function display for bus, ext. auxiliary voltage, inputs and outputs Detection of overload on sensor supply Detection of output overload

MPNs 188848, PEP188848, VAA-4E4A-G2-ZA/EA2
HS Code 85371091
Weight 0.15 kg

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Available on request

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  VAA-4E4A-G2-ZA/EA2 Product Description G2 flat module4 inputs (PNP) and 4 electronic outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Functional safety related parameters MTTFd140 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA (without sensors) / max. 220 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 180 mA (TB ≤ 40 °C),≤ 140 mA (TB ≤ 60 °C), , overload and short-circuit protected Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current2 A per output Sum 4 A (TB ≤ 40 °C) Sum 3 A (TB ≤ 60 °C) Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2001 Programming instructions ProfileS-7.F IO code7 ID codeF ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2not used P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP67 ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector Material HousingPBT Mass150 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VAA-4E4A-G2-ZA/EA2 Product Description G2 flat module4 inputs (PNP) and 4 electronic outputs General specifications Node typeStandard node AS-Interface specificationV3.0 Required master specification≥ V2.0 UL File NumberE223772 Functional safety related parameters MTTFd140 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 4 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 40 mA (without sensors) / max. 220 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC Supplyfrom AS-Interface Voltage21 ... 31 V Current loading capacity≤ 180 mA (TB ≤ 40 °C),≤ 140 mA (TB ≤ 60 °C), , overload and short-circuit protected Input current≤ 9 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 3 mA 1 (attenuated)≥ 5 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type4 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Current2 A per output Sum 4 A (TB ≤ 40 °C) Sum 3 A (TB ≤ 60 °C) Voltage≥ (UAUX - 0.5 V) Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Standard conformity Degree of protectionEN 60529:2000 Fieldbus standardEN 62026-2:2013 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2001 Programming instructions ProfileS-7.F IO code7 ID codeF ID1 codeF ID2 codeE Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 OUT4 Parameter bits (programmable via AS-i)function P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition P1not used P2not used P3not used Ambient conditions Ambient temperature-25 ... 60 °C (-13 ... 140 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity85 % , noncondensing Climatic conditionsFor indoor use only Altitude≤ 2000 m above MSL Pollution degree3 Mechanical specifications Degree of protectionIP67 ConnectionCable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector Material HousingPBT Mass150 g Tightening torque, cable gland0.4 Nm MountingMounting plate Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Our Company Reviews