VBA-4E2A-KE1-Z/E2 PEPPERL+FUCHS - Part number: 117993
Out of Stock - Backorder
To order from manufacturer
USD271.04

Import Taxes Excluded

You must be logged

VBA-4E2A-KE1-Z/E2 PEPPERL+FUCHS - Part number: 117993

PEPPERL+FUCHS

AS-Interface sensor/actuator module VBA-4E2A-KE1-Z/E2 VBA-4E2A-KE1-Z/E2 A/B node with extended addressing possibility for up to 62 nodes Housing with removable terminals Communication monitoring Inputs for 2-wire sensors and mechanical contacts Addressing jack Power supply of outputs from the external auxiliary voltage Power supply of inputs from the module Function display for bus, ext. auxiliary voltage, inputs and outputs AS-Interface sensor/actuator module VBA-4E2A-KE1-Z/E2 VBA-4E2A-KE1-Z/E2 A/B node with extended addressing possibility for up to 62 nodes Housing with removable terminals Communication monitoring Inputs for 2-wire sensors and mechanical contacts Addressing jack Power supply of outputs from the external auxiliary voltage Power supply of inputs from the module Function display for bus, ext. auxiliary voltage, inputs and outputs

MPNs 117993, PEP117993, VBA-4E2A-KE1-Z/E2
HS Code 85371091
Weight N/A

The product image is for illustrative purposes only.
The country of origin, HS code, and description are provided by the manufacturer and may be subject to change without prior notice. For this reason, PLC-City cannot be held responsible for any discrepancies.
Sold by PLC-CITY® and shipped from Italy

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

USD271.04

Import Taxes Excluded

You must be logged
Sold by PLC-CITY® and shipped from Italy
We are a Specialist Partner of PEPPERL+FUCHS
Free express shipping to United States
Loader...
View all shipping services
Request a quote to know the delivery date

We accept many payment methods: Bank Transfer (SEPA, ACH), Debit/Credit Cards (Mastercard, VISA, American Express, Diners Club, Discover, JCB, UnionPay), PayPal, ApplePay, GooglePay, link by Stripe, Cartes Bancaires, Alipay, Bancontact, blik, eps, giropay iDeal, Przelewy24, WeChatPay.
More information about our payment methods

This product is covered by a 12 Months warranty, valid for manufacturing defects or malfunctions. The warranty does not cover damage caused by improper use or accidental damage.
Learn more about our warranty

Returns are subject to prior authorization and eligible for store credit only. Backordered items are excluded.

View our return policy

Get your personalized quote now

A dedicated sales representative will assist you to offer the best price and delivery times.

You must be logged

Product information

Description

Datasheet excerpt: Technical data of  VBA-4E2A-KE1-Z/E2 Product Description KE1 switch cabinet module4 inputs and 2 outputs General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE87056 Functional safety related parameters MTTFd270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 2 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 25 mA (without sensors) / max. 60 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts Supplyfrom AS-Interface Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type2 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) CurrentO1/O2 max. 1.5 A, total 3 A (TB ≤ 40 °C)O1/O2 max. 1 A, total 2 A (TB ≤ 70 °C) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2001 Programming instructions ProfileS-7.A.0 IO code7 ID codeA ID1 code7 ID2 code0 Data bits (function via AS-Interface)InputOutput D0 IN1 O1 D1 IN2 O2 D2 IN3 - D3 IN4 - Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity90 % , noncondensing Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535 Datasheet excerpt: Technical data of  VBA-4E2A-KE1-Z/E2 Product Description KE1 switch cabinet module4 inputs and 2 outputs General specifications Node typeA/B node AS-Interface specificationV2.1 Required gateway specification≥ V2.1 UL File NumberE87056 Functional safety related parameters MTTFd270 a Mission Time (TM)20 a Diagnostic Coverage (DC)0 % Indicators/operating means LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of outputs LED PWRAS-Interface voltage; LED green LED AUXext. auxiliary voltage UAUX ; LED green LED INswitching state (input); 4 LED yellow LED OUTSwitching state (output); 2 LED yellow Electrical specifications Auxiliary voltage (output)20 ... 30 V DC PELV Rated operating voltage26.5 ... 31.6 V from AS-Interface Rated operating current≤ 25 mA (without sensors) / max. 60 mA Protection classIII Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) Input Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts Supplyfrom AS-Interface Input current≤ 8 mA (limited internally) Switching pointaccording to DIN EN 61131-2 (Type 2) 0 (unattenuated)≤ 2 mA 1 (attenuated)≥ 4 mA Signal delay< 2 ms (input/AS-Interface) Signal frequency≤ 250 Hz Output Number/Type2 electronic outputs, PNP, overload and short-circuit proof Supplyfrom external auxiliary voltage UAUX Voltage≥ (UAUX - 0.5 V) CurrentO1/O2 max. 1.5 A, total 3 A (TB ≤ 40 °C)O1/O2 max. 1 A, total 2 A (TB ≤ 70 °C) Usage categoryDC-13 Directive conformity Electromagnetic compatibility Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Standard conformity Degree of protectionEN 60529:2000 InputEN 61131-2:2007 Emitted interferenceEN 61000-6-4:2001 AS-InterfaceEN 62026-2:2013 Noise immunityEN 61000-6-2:2001 Programming instructions ProfileS-7.A.0 IO code7 ID codeA ID1 code7 ID2 code0 Data bits (function via AS-Interface)InputOutput D0 IN1 O1 D1 IN2 O2 D2 IN3 - D3 IN4 - Parameter bits (programmable via AS-i)function P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) P3not used Ambient conditions Ambient temperature-25 ... 70 °C (-13 ... 158 °F) Storage temperature-25 ... 85 °C (-13 ... 185 °F) Relative humidity90 % , noncondensing Pollution degree2 Mechanical specifications Degree of protectionIP20 Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 Material HousingPA 66-FR Mass80 g MountingDIN mounting rail Classifications SystemClasscode ECLASS 11.027242604 ECLASS 10.0.127242604 ECLASS 9.027242604 ECLASS 8.027242604 ECLASS 5.127242604 ETIM 8.0EC001599 ETIM 7.0EC001599 ETIM 6.0EC001599 ETIM 5.0EC001599 UNSPSC 12.139121535

Our Company Reviews